UDS1100 User Guide 2 Copyright & Trademark © 2006, Lantronix. All rights reserved. No part of the contents of this book may be transmitted or reproduced in any form or by any means without the written permission of Lantronix. Printed in the United States of America. Ethernet is a trademark of XE...
UDS1100 User Guide 3 Contents 1: Using This Guide 7 Purpose and Audience _______________________________________________ 7 Chapter Summary ___________________________________________________ 7 Additional Documentation _____________________________________________ 8 2: Introduction 9 Applications ___...
Contents UDS1100 User Guide 6 D: Compliance and Disclaimer 80 Index 82 Figures Figure 2-1. Serial Tunneling Example _____________________________________ 10 Figure 2-2. Direct TCP/IP or Redirector Configuration ________________________ 10 Figure 2-3. Sample Hardware Address _________________________...
UDS1100 User Guide 7 1 1 : : U U s s i i n n g g T T h h i i s s G G u u i i d d e e Purpose and Audience This guide provides the information needed to configure, use, and update the UDS1100 device server. It is for system administrators and those responsible for installing and maintaining the UDS. ...
1: Using This Guide UDS1100 User Guide 8 B: Binary to Hexadecimal Conversions Provides instructions for converting binary values to hexadecimals. Additional Documentation The following information is available on the product CD or the Lantronix Web site: www.lantronix.com UDS1100 Quick Start Provide...
2: Introduction UDS1100 User Guide 11 Protocol Support The UDS uses the Internet Protocol (IP) for network communications and the Transmission Control Protocol (TCP) to assure that no data is lost or duplicated and that everything sent to the connection arrives correctly at the target. Supported pro...
2: Introduction UDS1100 User Guide 12 Product Information Label The product information label on the underside of the unit contains the following information about your specific unit: Bar code Serial number Product ID (name) Product description Hardware address (also referred to as the Eth...
UDS1100 User Guide 13 3 3 : : G G e e t t t t i i n n g g S S t t a a r r t t e e d d This chapter describes how to get your UDS up and running in the shortest possible time. Package Contents Verify and inspect the contents of the UDS1100 package using the following list. If any item is missing or d...
3: Getting Started UDS1100 User Guide 14 Installing the UDS Figure 3-1. UDS1100 Connected to Serial Device and Network To install the unit: Complete the following steps in order. Refer to the numbers in the figure above. Note: See the sections that follow for details about connectors and pinouts. 1....
3: Getting Started UDS1100 User Guide 15 Required Information Before configuring the UDS, have the following information available: Hardware Address Take note of the unit’s hardware address (also known as the Ethernet or MAC address). It is on the product label, in the format: 00-20-4a-XX-XX-XX, whe...
3: Getting Started UDS1100 User Guide 16 Assigning the IP Address: DeviceInstaller This chapter covers the steps for getting the UDS1100 device server online and for viewing its current configuration. Note: DeviceInstaller online Help provides more detailed information on using DeviceInstaller. Inst...
3: Getting Started UDS1100 User Guide 17 7. Select the device from the main window list and select Ping from the Tools menu. The Ping Device dialog box shows the IP address of the selected unit. 8. From the Tools menu, click the Ping button. The results display in the Status window. Click the Clear ...
3: Getting Started UDS1100 User Guide 18 Type Non-configurable field. Displays the device type as UDS1100. ID Non-configurable field. Displays the UDS1100’s ID embedded within the box. Hardware Address Non-configurable field. Displays the UDS1100’s hardware (or MAC) address. Firmware Version Non-con...
3: Getting Started UDS1100 User Guide 19 Supports Configurable Pins Non-configurable field. Displays False . Supports Email Triggers Non-configurable field. Displays False . Supports AES Data Stream Non-configurable field. Displays False. Supports 485 Non-configurable field. Displays True. The UDS11...
UDS1100 User Guide 21 4 4 : : C C o o n n f f i i g g u u r r a a t t i i o o n n U U s s i i n n g g W W e e b b - - M M a a n n a a g g e e r r You must configure the unit so it can communicate on a network with your serial device. For example, you must set the way the unit will respond to serial ...
4: Configuration Using Web-Manager UDS1100 User Guide 22 Figure 4-1. Lantronix Web-Manager The main menu is in the left pane of the Web-Manager window. Network Configuration The unit’s network values display when you select Network from the main menu. The following sections describe the configurable...
4: Configuration Using Web-Manager UDS1100 User Guide 24 4. When you are finished, click the OK button. 5. On the main menu, click Apply Settings . Ethernet Configuration You must specify the speed and direction of data transmission. To specify how data will be transmitted: 1. On the main menu, clic...
4: Configuration Using Web-Manager UDS1100 User Guide 25 Figure 4-3. Server Settings To configure the UDS1100’s device server settings: 1. On the main menu, click Server . 2. Configure or modify the following fields: Server Configuration Telnet Password Enter the password required for Telnet access....
4: Configuration Using Web-Manager UDS1100 User Guide 26 MTU Size The Maximum Transmission Unit (MTU) is the largest physical packet size a network can transmit for TCP and UDP. Enter between 512 and 1400 bytes. The default setting is 1400 bytes. 3. When you are finished, click the OK button. 4. On ...
4: Configuration Using Web-Manager UDS1100 User Guide 27 Retry Timeout Enter the duration (in seconds) the UDS1100 should abandon attempting a connection to the host list. The default setting is 250 . Host Information Host Address Enter or modify the host’s IP address. Port Enter the target port num...
4: Configuration Using Web-Manager UDS1100 User Guide 28 Channel 1 Disable Serial Port When selected, disables communication through the serial port. The serial port is enabled by default. Note: This feature is not available on single port device servers. Port Settings Protocol From the drop-down me...
4: Configuration Using Web-Manager UDS1100 User Guide 29 Match Bytes Use to indicate the end of a series of data to be sent as one group. Set this value to 00 if specific functions are not needed. Send Frame Only After the detection of the byte sequence, indicates whether to send the data frame or t...
4: Configuration Using Web-Manager UDS1100 User Guide 30 Figure 4-6. TCP Connection Settings 2. In the available fields, enter or modify the following information: Connect Protocol Protocol From the drop-down menu, select TCP. Connect Mode: Passive Connection Accept Incoming Select Yes to accept inc...
4: Configuration Using Web-Manager UDS1100 User Guide 32 Use Hostlist If this option is set to True , the device server scrolls through the host list until it connects to a device listed in the host list table. Once it connects, the unit stops trying to connect to any others. If this connection fail...
4: Configuration Using Web-Manager UDS1100 User Guide 33 Figure 4-7. UDP Connection Settings Connect Protocol Protocol Select UDP from the drop-down menu. Datagram Mode Datagram Type Configures the remote IP or network broadcast address and the remote port. Enter 01 for directed or broadcast UDP. Th...
4: Configuration Using Web-Manager UDS1100 User Guide 34 Device Address Table The table is enabled when Datagram Type is set to FD . Enter values between 1 and 255 to identify units on the local network of device servers. Note: Lantronix Tech Support supports Datagram type 01 . Datagram Type FD is f...
UDS1100 User Guide 35 5 5 : : C C o o n n f f i i g g u u r r a a t t i i o o n n v v i i a a T T e e l l n n e e t t o o r r S S e e r r i i a a l l P P o o r r t t ( ( S S e e t t u u p p M M o o d d e e ) ) You must configure the unit so it can communicate on a network with your serial device. As...
5: Configuration via Telnet or Serial Port (Setup Mode) UDS1100 User Guide 36 Figure 5-1. MAC Address 3. To enter Setup Mode, press Enter within 5 seconds . The configuration settings display, followed by the Change Setup menu. Figure 5-2. Setup Menu Options 4. Select an option on the menu by enteri...
UDS1100 User Guide 37 6 6 : : S S e e t t u u p p M M o o d d e e : : S S e e r r v v e e r r C C o o n n f f i i g g u u r r a a t t i i o o n n This chapter explains how to configure the network settings. Note: Current values display in parentheses. Server Configuration (Option 0) The unit’s basic...
6: Setup Mode: Server Configuration UDS1100 User Guide 38 default setting is N (No), meaning the gateway address has not been set. To set the gateway address, type Y and enter the address. Set Gateway IP Address (N) ? Y Gateway IP addr (000) (000) (000) (000)_ Netmask: Number of Bits for Host Part A...
6: Setup Mode: Server Configuration UDS1100 User Guide 39 There are three methods for assigning DHCP names to the unit. Default DHCP Name : If you do not change the DHCP name, and you are using an IP of 0.0.0.0, then the DHCP name defaults to XX.XX.XX.XX (XXXXXX is the last 6 digits of the MAC add...
UDS1100 User Guide 40 7 7 : : S S e e t t u u p p M M o o d d e e : : C C h h a a n n n n e e l l C C o o n n f f i i g g u u r r a a t t i i o o n n This chapter explains how to configure the serial port. Notes: Current values display in parenthesis. You must enter some values in hexadecimal no...
7: Setup Mode: Channel Configuration UDS1100 User Guide 41 I/F (Interface) Mode The Interface (I/F) Mode is a bit-coded byte entered in hexadecimal notation. The default setting is 4C . Figure 7-2. Interface Mode I/F Mode (4C) ? _ The following table displays available I/F Mode options: Note: All bi...
7: Setup Mode: Channel Configuration UDS1100 User Guide 42 Use the following table to select flow control options: Table 7-3. Flow Control Options Flow Control Option Hex No flow control 00 XON/XOFF flow control 01 Hardware handshake with RTS/CTS lines 02 XON/XOFF pass characters to host 05 Port Num...
7: Setup Mode: Channel Configuration UDS1100 User Guide 43 Table 7-5. Connect Mode Options Connect Mode Option 7 6 5 4 3 2 1 0 a) Incoming Connection Never accept incoming 0 0 0 Accept with DTR Active 0 1 0 Always Accept 1 1 0 b) Response Nothing (quiet) 0 Character response (C=connect, D=disconnect...
7: Setup Mode: Channel Configuration UDS1100 User Guide 45 Figure 7-3. Manual Connection Address Example Command String Result if remote IP is 129.1.2.3 and remote port is 1234 C121.2.4.5/1 Complete override; connection is started with host 121.2.4.5, port 1. C5 Connects to 129.1.2.5, port 1234. C28...
7: Setup Mode: Channel Configuration UDS1100 User Guide 46 To enable the hostlist: 1. Enter a Connect Mode of 0x20 ( 2 X), where X is any digit. The menu shows you a list of current entries already defined in the product. 2. To delete, modify, or add an entry, select Yes . If you enter an IP address...
7: Setup Mode: Channel Configuration UDS1100 User Guide 48 When an active connection is in effect, the unit terminates the connection if it receives the following sequence from the attached serial device: No serial data is received for one second. The character sequence +++ is received, with no ...
7: Setup Mode: Channel Configuration UDS1100 User Guide 49 Send the Escape Sequence (+++) in Modem Mode Send ‘+++’ in Modem Mode (Y) ? _ Disable or enable the UDS1100’s ability to send the escape sequence. The default setting is Y (Yes) (send the escape sequence). Auto Increment Source Port Auto inc...
7: Setup Mode: Channel Configuration UDS1100 User Guide 50 Table 7-7. Disconnect Mode Options Disconnect Mode Option 7 6 5 4 3 2 1 0 Disconnect with DTR drop (6) 1 Ignore DTR 0 Telnet mode and terminal type setup (1) 1 Channel (port) password (2) 1 Hard disconnect (3) 0 Disable hard disconnect 1 Sta...
7: Setup Mode: Channel Configuration UDS1100 User Guide 51 Table 7-8. Flush Mode Options Function 7 6 5 4 3 2 1 0 Input Buffer (Serial to Network) Clear with a connection initiated from the device to the network 1 Clear with a connection initiated from the network to the device 1 Clear when the netw...
7: Setup Mode: Channel Configuration UDS1100 User Guide 52 Option 7 6 5 4 3 2 1 0 Send Characters 2-Byte Send Character Sequence 1 Send Immediately After Send chars 1 Packing Interval Packing Interval defines how long the unit should wait before sending accumulated characters. This wait period is be...
7: Setup Mode: Channel Configuration UDS1100 User Guide 53 disables the recognition of the characters. Alternatively, the unit can interpret two characters as a sequence (see Pack Control on page 51). The default setting is 00. Telnet Terminal Type This parameter displays only if you enabled the ter...
UDS1100 User Guide 54 8 8 : : S S e e t t u u p p M M o o d d e e : : A A d d v v a a n n c c e e d d S S e e t t t t i i n n g g s s Expert Settings (Option 5) Note: You can change these settings using Telnet or serial connections only, not on the Web-Manager. Caution: Changing the expert settings ...
8: Setup Mode: Advanced Settings UDS1100 User Guide 55 ARP Cache timeout in seconds Whenever the unit communicates with another device on the network, it adds an entry into its ARP table. The ARP Cache timeout option allows you to define how many seconds (1-600) the unit will wait before timing out ...
8: Setup Mode: Advanced Settings UDS1100 User Guide 56 Security Settings (Option 6) You can change security settings by means of Telnet or serial connections only, not on the Web-Manager. We recommend that you set security over the dedicated network or over the serial setup to prevent eavesdropping....
8: Setup Mode: Advanced Settings UDS1100 User Guide 57 Disable TFTP Firmware Update This setting defaults to the N (No) option. The Y (Yes) option disables the use of TFTP to perform network firmware upgrades. With this option, you can download firmware upgrades over the serial port using DeviceInst...
8: Setup Mode: Advanced Settings UDS1100 User Guide 58 Default Settings (Option 7) Select 7 to reset the unit’s Channel 1 configuration and expert settings to the default settings. The server configuration settings for IP address, gateway IP address, and netmask remain unchanged. The configurable pi...
UDS1100 User Guide 60 9 9 : : F F i i r r m m w w a a r r e e U U p p g g r r a a d d e e s s Obtaining Firmware You can obtain the most up-to-date firmware and release notes for the unit from the Lantronix web site ( www.lantronix.com ) or by using anonymous FTP ( ftp.lantronix.com ). Reloading Fir...
9: Firmware Upgrades UDS1100 User Guide 61 Figure 9-1. TFTP Window After the firmware has been loaded and stored, which takes approximately 8 seconds to complete, the unit performs a power reset. Using TFTP: Command Line Interface To download new firmware from a computer: 1. Enter the following from...
9: Firmware Upgrades UDS1100 User Guide 62 5. For Firmware File , click the Browse button and go to the location where the firmware file resides. Note : Make sure the UDS1100 on which you are recovering firmware is connected to this selected port on your PC. 6. Click OK to download the file. 7. When...
UDS1100 User Guide 63 1 1 0 0 : : M M o o n n i i t t o o r r M M o o d d e e Monitor Mode is a command-line interface used for diagnostic purposes. There are two ways to enter Monitor Mode: locally using the serial port or remotely using the network. Entering Monitor Mode Using the Serial Port To e...
10: Monitor Mode UDS1100 User Guide 64 Table 10-1. Monitor Mode Commands Command Command Name Function VS x.x.x.x Version Queries software header record (16 bytes) of unit with IP address x.x.x.x. GC x.x.x.x Get Configuration Gets configuration of unit with IP address x.x.x.x as hex records (120 byt...
UDS1100 User Guide 65 1 1 1 1 : : T T r r o o u u b b l l e e s s h h o o o o t t i i n n g g a a n n d d C C o o n n t t a a c c t t I I n n f f o o r r m m a a t t i i o o n n This chapter discusses how you can diagnose and fix errors quickly without having to contact a dealer or Lantronix. It hel...
11: Troubleshooting and Contact Information UDS1100 User Guide 66 Problems and Error Messages Table 11-2. Problems and Error Messages Problem/Message Reason Solution When you issue the ARP –S command in Windows, the "ARP entry addition failed: 5" message displays. Your currently logged-in us...
11: Troubleshooting and Contact Information UDS1100 User Guide 67 Problem/Message Reason Solution When you try to assign an IP with DeviceInstaller, you get the following : "No response from device! Verify the IP, Hardware Address and Network Class. Please try again." The cause is most likel...
11: Troubleshooting and Contact Information UDS1100 User Guide 68 Problem/Message Reason Solution The device server appears to be set up correctly, but you are not communicating with your device attached to the device server across the network. If you are sure that the serial port setting is correct...
UDS1100 User Guide 69 1 1 2 2 : : C C o o n n n n e e c c t t i i o o n n s s a a n n d d P P i i n n o o u u t t s s Serial Port The UDS has a female DCE DB25 serial port that supports RS-232 and RS-485/422 serial standards (software selectable) up to 230 Kbaud. Figure 12-1. Serial Interface Serial...
12: Connections and Pinouts UDS1100 User Guide 70 Figure 12-3. DB25 Female Interface RS422 (4 wire mode) Figure 12-4. DB25 Female Interface RS485 (2 wire mode) Modem Cable When attaching the DB25 of the UDS to the DB9 com port on a PC, use a standard straight-through serial cable (Lantronix Part No....
12: Connections and Pinouts UDS1100 User Guide 71 Figure 12-5. Null Modem Cable (Lantronix Part No. 500-163) Network Port The unit's back panel contains a power plug and an RJ45 (10/100) Ethernet port. Figure 12-6. Network Interface RJ45 Ethernet Port Power Plug
12: Connections and Pinouts UDS1100 User Guide 72 Ethernet Connector Pinouts The UDS1100 supports 10/100 Mbps half or full duplex Ethernet through an RJ45 connector. Figure 12-7. RJ45 Ethernet Connector Power Plug Power input on the power plug is 9 -30 VDC (center +) or 10-24 VAC (1.5W maximum power...
13: Technical Specifications UDS1100 User Guide 74 Category Description DeviceInstaller software System Software DeviceInstaller, Windows® 95/98/ME/NT/2000/XP-based configuration software Com Port Redirector, Windows® 98/NT/2000/XP-based virtual com port software LEDs Power 10/100 Mb Link 10/100 Act...
UDS1100 User Guide 75 A A : : A A l l t t e e r r n n a a t t i i v v e e W W a a y y s s t t o o A A s s s s i i g g n n a a n n I I P P A A d d d d r r e e s s s s Earlier chapters describe how to assign a static IP address using DeviceInstaller, Web Manager, and Setup Mode (through a Telnet or se...
A: Alternative Ways to Assign an IP Address UDS1100 User Guide 76 BOOTP Similar to DHCP, but for smaller networks. Automatically assigns the IP address for a specific duration of time. ARP and Telnet If the unit has no IP address, you can use Address Resolution Protocol (ARP) method from UNIX and Wi...
UDS1100 User Guide 77 B B : : B B i i n n a a r r y y t t o o H H e e x x a a d d e e c c i i m m a a l l C C o o n n v v e e r r s s i i o o n n s s Many of the unit’s configuration procedures require assembling a series of options (represented as bits) into a complete command (represented as a byt...
B: Binary to Hexadecimal Conversions UDS1100 User Guide 78 Scientific Calculator Another simple way to convert binary to hexadecimals is to use a scientific calculator, such as the one available on Windows’ operating systems. For example: 1. On the Windows’ Start menu, click Programs Æ Accessories Æ...
UDS1100 User Guide 79 C C : : W W a a r r r r a a n n t t y y Lantronix warrants each Lantronix product to be free from defects in material and workmanship for a period of TWO YEARS after the date of shipment. During this period, if a customer is unable to resolve a product problem and Lantronix Tec...
UDS1100 User Guide 80 D D : : C C o o m m p p l l i i a a n n c c e e a a n n d d D D i i s s c c l l a a i i m m e e r r Manufacturer’s Name & Address Lantronix 15353 Barranca Parkway, Irvine, CA 92618 USA Declares that the following product: Product Name Model : UDS1100 Device Server Conforms ...
D:Compliance and Disclaimer UDS1100 User Guide 81 Disclaimer and Supplementary Information This product has been designed to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against such interference when...
UDS1100 User Guide 82 Index Applications, 9 ARP and Telnet, 76 AutoIP, 15, 75 Binary to hexadecimal conversions, 77 BOOTP, 15, 76 Channel settings, 27, 40 Command line interface, 35 Configuration methods, 11 Connect Mode, 42 Connection settings TCP, 29 UDP, 32 Connectors, 69 Contacts, 2 Default sett...
Lantronix Manuals
-
Lantronix EPS4-100
Manual
-
Lantronix 900-603
Manual
-
Lantronix EDS2100
Manual
-
Lantronix 2100
Manual
-
Lantronix 1-T2
Manual
-
Lantronix EDS1100
Manual
-
Lantronix MSS100
Manual
-
Lantronix MPS100
Manual
-
Lantronix MPS1-T
Manual
-
Lantronix XPress DR+
Manual
-
Lantronix UBX4100
Manual
-
Lantronix EDS4100
Manual
-
Lantronix ETS32PR
Manual
-
Lantronix MPS1-2
Manual
-
Lantronix UDS2100
Manual
-
Lantronix ETS16PS
Manual
-
Lantronix 10
Manual
-
Lantronix 900-563
Manual
-
Lantronix EDS16PR
Manual
-
Lantronix EDS8/16PS
Manual