Page 2 - OBTAINING THE CHEMICALS; Catalog numbers are as follows:; CONVERTING TO THE; KODAK; Preparing Fresh Working Tank Solutions; Follow the directions
2 Using the KODAK Negative Film Processing Cartridges FC1 and FC2 • CIS-254 OBTAINING THE CHEMICALS Catalog numbers are as follows: Product Min/Mult Order Qty CAT Number KODAK Negative Film Processing Cartridge FC1 2 801 7519 KODAK Negative Film Processing Cartridge FC2 2 867 2701 KODAK Rinse Tablet...
Page 3 - Use K; Water Reservoir; Add; Figure 1; Cartridge Chemistry
Using the KODAK Negative Film Processing Cartridges FC1 and FC2 • CIS-254 3 Bleach Tank (N2) Use KODAK Negative Film FC Tank Bleach, CAT No. 107 2024 . Each kit makes 3.6 litres of tank bleach solution. One kit is required to prepare the bleach tank in either the FP363SC processor or the FP563SC pro...
Page 4 - USING; Plotting Control-Strip Densities; If you are using an older code of control strip
4 Using the KODAK Negative Film Processing Cartridges FC1 and FC2 • CIS-254 USING KODAK CONTROL STRIPS, PROCESS C-41, TO MONITOR THE PROCESS Use KODAK Control Strips, Process C-41, to monitor process performance Each time you process a control strip, position it in the same location in the processor...
Page 5 - Additional Process CN-16S; First check for operational errors:
Using the KODAK Negative Film Processing Cartridges FC1 and FC2 • CIS-254 5 Additional Process CN-16S Adjustment Factors for Use with Process C-41 Control Strips Step R G B Yellow 0.00 0.00 0.00 D-max 0.00 0.00 +0.07 HD +0.04 0.00 +0.07 LD 0.00 0.00 0.00 D-min 0.00 0.00 0.00 4. Process a control str...
Page 6 - Operating Minilabs at Low Levels of; • For high LD plots:
6 Using the KODAK Negative Film Processing Cartridges FC1 and FC2 • CIS-254 HD-LD (Contrast): This parameter monitors developer activity. Contrast is the primary indicator of developer agitation, oxidation, concentration, or contamination. If the developer tank solution is under-agitated, too dilute...
Page 7 - MANAGING EMPTY CARTRIDGES; Recycling KODAK; SILVER RECOVERY
Using the KODAK Negative Film Processing Cartridges FC1 and FC2 • CIS-254 7 D-min (Clear Area of Film): This parameter may monitor developer, bleach, or fixer problems. If a developer problem is indicated, see the HD-LD or LD parameter for confirmation and corrective action. If a bleach or fixer pro...
Page 8 - Figure 2; LD; Developer; Process; Relative Height of
8 Using the KODAK Negative Film Processing Cartridges FC1 and FC2 • CIS-254 Figure 2 0 .05 .10 .15 .20 .25 + - .05.10.15.20.25 0 .05 .10 .15 .20 .25 + - .05.10 .15.20.25 0 .05 .10 .15 + - .05.10.15 0 .05 + - .05 D-max B - Y B (+ 0.10 & 0.12) BleachActivity - retained silver HD-LD (+/- 0.07 &...
Page 9 - Reference Aims Worksheet; Red Green Blue
Using the KODAK Negative Film Processing Cartridges FC1 and FC2 • CIS-254 9 Process CN-16S Reference Aims Worksheet Date: Code: Red Green Blue D-max b Density Readings Control Strip Correction Factor Corrected D-max Yellow b Density Reading Control Strip Correction Factor Corrected Yellow b AIM D-ma...
Page 10 - EASTMAN KODAK COMPANY • ROCHESTER, NY 14650
Note: The contents of this publication are subject to change. To be sure you have the most up-to-date publication, check www.kodak.com/go/photochemicals; select Technical Information to find Current Information Summaries . Digital & Film Imaging Systems EASTMAN KODAK COMPANY • ROCHESTER, NY 1465...