A-61097 May 1997 1-1 1 Introduction The KODAK DIGITAL SCIENCE™ Mode Setup Software 9000 has beendeveloped to enable you to customize applications using the: • KODAK DIGITAL SCIENCE Document Scanner 9500 • KODAK DIGITAL SCIENCE Scanner/Microimager 990 • KODAK IMAGELINK Microimager 70 • KODAK IMAGELIN...
1-2 A-61097 May 1997 Software Installation Procedure Follow these steps to install the software: 1. Insert the Mode Setup Software diskette into the drive. 2. Type A:INSTALL next to the DOS prompt and press Return/Enter. If the disk drive on your unit is not designated as the A drive, substitutethe ...
A-61097 May 1997 1-5 FILE COPY COMPLETE Please enter the name of the registered user below: _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Please Wait While Files Are Being Copied To Your Destination Drive. REGISTRATION 7. Type in user name. Press Return/Enter. Type “setup” ...
1-6 A-61097 May 1997 Logon Procedure After the installation procedure has been performed, follow these steps tolog on to the Mode Setup Software: 1. Access DOS. 2. Change the directory to correspond to the directory designated during the installation procedure. 3. Type setup and press Return/Enter. ...
A-61097 May 1997 1-7 5. Select Continue. Display Machine AccessoriesMachine ID NumberDisplay LanguageMeasurement SystemProgrammable Function KeysDate FormatTime FormatAlarm ToneDoc Printer/Film Writer MsgDP-12 Print TemplateFixed Field DelimiterSet System ClockVersion NumbersUser COIN Port ProtocolC...
1-8 A-61097 May 1997 • Each window should contain an option entitled Previous Menu.Typically, you are returned to the previous menu after completing adefinition. If you are not returned to the previous menu after completinga definition, or you want to return without altering the default orpreviously...
A-61097 May 1997 1-9 Logout Procedure Once you have completed the installation, the following sequence of stepsmay be used to log out of the system. From the Mode Configuration window: 1. Select Save & End Session if you wish to save all of the definitions or Don’t Save & End Session if you ...
A-61097 May 1997 2-1 2 Machine Definitions The following section lists the items on the Mainframe Configuration Menuthat may be selected for definition. Display Machine AccessoriesMachine ID NumberDisplay LanguageMeasurement SystemProgrammable Function KeysDate FormatTime FormatAlarm ToneDoc Printer...
2-2 A-61097 May 1997 Display Machine Accessories This option displays the status of the various machine accessories and isfor viewing only; no selections or entries are made. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Display ...
A-61097 May 1997 2-3 Machine ID Number This option establishes a unique identification number for each unit in amultiple-unit installation. The default is 00. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Machine ID Number. 2. En...
2-4 A-61097 May 1997 Display Language This option defines the primary display language. The default is English. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Display Language. 2. Select the desired language option. Display Machin...
A-61097 May 1997 2-5 Measurement System This option defines the primary measurement system. English uses inchesas the primary unit of measure. Metric uses millimetres as the primary unitof measure. The default is English. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Mi...
2-8 A-61097 May 1997 The following default values apply only to the Scanner/Microimager 990: Definition Key P1 P2 P3 P4 P5 P6 P7 P8 P9 P10 f04,2 f45 f09 f08 f37 f30 f44 f46 f07 f98f38 Count only, toggle Print test Total document count Last Image Address Calibrate Amount of film remaining Omit printi...
A-61097 May 1997 2-9 Date Format This option defines the date display format, both the date format anddelimiter. Refer to Description 1: Date Format Samples for a descriptionof the available formats. The default is mmddyy. The default delimiter is aslash (/). ❏ Microimager 70 ■ Microimager 70/AFM ■ ...
2-10 A-61097 May 1997 Description 1: Date Format Samples Sample DateMarch 1, 1991 Slash Dash Period Space None mmddyy 03/01/91 03/01/91 03.01.91 03 01 91 030191 mmdd 03/01 03-01 03.01 03 01 0301 ddmmmyy 01/MAR/91 01-MAR-91 01.MAR.91 01 MAR 91 01MAR91 ddmmm 01/MAR 01-MAR 01.MAR 01 MAR 01MAR mmyy 03/9...
A-61097 May 1997 2-11 Time Format This option defines the time display format. Refer to Description 2: TimeFormat Samples for a description of the available formats. The default is12 hour with AM/PM. ❏ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanne...
2-12 A-61097 May 1997 Alarm Tone This option defines tone or pitch of the audible alarm. The default is High. ❏ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Alarm Tone. 2. Select the desired alarm tone pitch. Display Machine Acces...
A-61097 May 1997 2-13 Document Printer/Film Writer Messages This option defines messages that may be printed by a document printeror film writer. ❏ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Doc Printer/Film Writer Msg. Messages...
2-14 A-61097 May 1997 Message 0 is predefined and cannot be changed. Messages 1 through 9 are programmable using the following sequence ofsteps: 1. Select a message number. 2. Press Return/Enter. 3. Enter the desired message text. 4. Press Return/Enter. Definition Msg 0 1 2 3 4 5 6 7 8 9 Prev Previo...
A-61097 May 1997 2-15 Print Template Setup This option defines as many as ten (10) unique print templates. The template definitions are used when programming Document Printer12 print definitions. The default print template is Print Template 1, whichprints Full IA w/No Delimiters on Line 1. ❏ Microim...
A-61097 May 1997 2-21 Fixed Field Delimiter This option defines the fixed field delimiter used in the Image AddressDisplay. The default is a Period (.). NOTE: The Fixed Field Delimiter doesn’t appear on the display; it appears when printing the Image Address. ❏ Microimager 70 ■ Microimager 70/AFM ■ ...
2-22 A-61097 May 1997 Set System Clock This option sets the system clock. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Set System Clock. Display Machine AccessoriesMachine ID NumberDisplay LanguageMeasurement SystemProgrammable ...
A-61097 May 1997 2-23 3. Verify that the terminal time should be downloaded by selecting Yes; or to cancel the download, select No. If the computer being used to program the unit does not have an internalclock or the internal clock is not accurate: 4. Select the time or date component you wish to de...
2-24 A-61097 May 1997 Version Numbers This option displays the current software version(s) installed in themachine and is for viewing only; no selections or entries are made. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Version ...
A-61097 May 1997 2-25 User COIN Port Protocol This option enables or disables the user COIN port for communicationprotocols associated with OCR data, Document Scanning Array / BarCode Reader, or Customer specified. The default value is Disabled. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ ...
2-28 A-61097 May 1997 9. Select Handshaking. 10. Select the handshaking protocol. Handshaking Baud RateParity BitChar. LengthHandshakingUpdate FF Previous Menu User COIN Port Config Display Machine AccessoriesMachine ID NumberDisplay LanguageMeasurement SystemProgrammable Function KeysDate FormatTim...
A-61097 May 1997 2-29 Custom Check Digit This option determines the check digit algorithm to be used when acustom check digit is calculated. NOTE: If a standard check digit algorithm is desired, specify the desired algorithm during Image Address print definitions within each modesetup. ❏ Microimager...
2-32 A-61097 May 1997 Sample check digit calculation #1 Assume the following: Image Address = 123.45.678.912 Attributes = 46231546231 Constant 1 = 7 Constant 2 = 10 Divisor = 11 Left/Right = Right LUT Status = No/off Lookup Table = abcdefghijk Then the check digit calculation would be: 1. Set up the...
A-61097 May 1997 2-33 Sample check digit calculation #2 Assume the following: Image Address = 123.45.678.912 Attributes = 46231546231 Constant 1 = 7 Constant 2 = 10 Divisor = 11 Left/Right = Right LUT Status = Yes/on Lookup Table = abcdefghijk Then the check digit calculation would be: 1. Set up the...
2-36 A-61097 May 1997 9. Select the Left/Right parameter for definition. 10. Select the digit to be used during calculation of the check digit. Check Digit = Constant 2 - [Sum of IA Digits * Attributes] + Constant 1 Divisor Current Value Parameter 46231546231 000007RightNoabcdefghijk Attributes Cons...
A-61097 May 1997 2-37 13. Select the Lookup Table parameter for definition. 14. Enter the desired lookup table values. Enter lookup table. Req’d entry 11 digits. abcdefghijk To Change: Enter ValueTo Retain: Press Enter Check Digit = Constant 2 - [Sum of IA Digits * Attributes] + Constant 1 Divisor C...
2-38 A-61097 May 1997 OI Hardware Character Set This option defines non-English character sets which may be used by theOperator Interface, Document Printers and the Film Writer. Englishcharacters are contained in both sets. The default OI character set isAnglo/Japanese. ❏ Microimager 70 ■ Microimage...
A-61097 May 1997 2-39 Save Configuration to PC This option is used to download a configuration file from the scanner ormicrofilmer onto diskette. This is useful in creating configuration fileswhich may be transported to other units (see the Load Config from PCoption). This is also used to create bac...
2-40 A-61097 May 1997 Load Configuration from PC This option is used to upload a configuration file from diskette to thescanner or microfilmer. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Load Configuration from PC. 2. Enter a ...
A-61097 May 1997 3-1 3 Selecting the Mode Configuration Window This section lists the Mode Definitions for the Scanner/Microimager.Follow these steps to select the Mode Definition screen. Display Machine AccessoriesMachine ID NumberDisplay LanguageMeasurement SystemProgrammable Function KeysDate For...
A-61097 May 1997 3-3 Mode Definitions The following section lists the items on the Mode Configuration Menu thatmay be selected for definition. Unavailable machine types are indicated byhollow boxes. Mode NameThis option defines the mode name. ❏ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Sca...
3-4 A-61097 May 1997 Index Format This mode defines the index format used by the application mode. Referto Description 3: Index Formats for a description of the index formats. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 When using a Micr...
A-61097 May 1997 3-5 Description 3: Index Formats There are five Index Format options available: Single Level IA 1 (Level 1) IA 2 (Level 1) IA 3 (Level 1) IA 4 (Level 1) Whenever a small image mark is placed next to a document and/or a document is assigned Level 1, the ImageAddress field associated ...
A-61097 May 1997 3-7 Image Address Display Format This mode defines the format of the Image Address display which appearson the control panel. The default is Suppress. ❏ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select IA Display Form...
3-8 A-61097 May 1997 Image Address Field Widths This mode defines the Image Address field widths.Refer to Description 4: Image Address Fields for a description of properfield definitions. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 When ...
3-10 A-61097 May 1997 Description 4: Image Address Fields An Image Address is a unique identifier assigned to each individual document by the Microimager 70, Scanner900, Scanner 923, Scanner 9500, or Scanner/Microimager 990. An Image Address may contain up to 15 characters, consisting of a maximum o...
3-12 A-61097 May 1997 Level Rules This mode defines the level of a document based upon the level of theprevious document. These definitions are used as defaults when thedocument level is not determined by another method (i.e., Footswitch,P-Key, Level Key, etc.) ■ Microimager 70 ■ Microimager 70/AFM ...
3-14 A-61097 May 1997 Batching This mode defines the number of documents of a specified level toprocess prior to performing a predefined action. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Batching. Batch LevelBatch ValueStart ...
A-61097 May 1997 3-15 Batch Value Defines the number of documents to be counted prior to performing apredefined action. The default value is 99. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Batch Value. Batch LevelBatch ValueSta...
3-16 A-61097 May 1997 Start of Batch Function This mode defines the action(s) to be taken prior to processing thedocument in the batch. The default value is Nothing. ❏ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Start of Batch Fu...
A-61097 May 1997 3-17 End of Batch Function This mode defines the action(s) to be taken after processing the documentin the batch. The default value is f98, Stop. ❏ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select End of Batch Functio...
3-18 A-61097 May 1997 AEC Mode This mode enables or disables Automatic Exposure Control. Fixed Modedisables Automatic Exposure Control. Auto Mode enables AutomaticExposure Control. The default value is Auto Mode. ■ Microimager 70 ■ Microimager 70/AFM ❏ Scanner 900 ❏ Scanner 923 ■ Scanner/Microimager...
A-61097 May 1997 3-19 Film Mode This mode defines the orientation of documents on film. Refer toDescription 5: Film Modes for a description of the available film modes.The default value is Duplex. ■ Microimager 70 ■ Microimager 70/AFM ❏ Scanner 900 ❏ Scanner 923 ■ Scanner/Microimager 990 ❏ Scanner 9...
A-61097 May 1997 3-21 Reduction Ratio This mode defines the level of magnification. The default value is Don’tCare. ❏ Microimager 70 ■ Microimager 70/AFM ❏ Scanner 900 ❏ Scanner 923 ■ Scanner/Microimager 990 ❏ Scanner 9500 1. Select Reduction Ratio. Reduction Ratio Don't Care24x 40x50x Previous Menu...
3-22 A-61097 May 1997 Number of Cassettes This mode defines the minimum number of cassettes that must beinstalled during filming. If Two Cassettes is chosen, you must always usetwo cassettes. If One Cassette is chosen, you may use one or twocassettes. The default value is One Cassette. ■ Microimager...
A-61097 May 1997 3-23 Film Writer NOTE: The Film Writing Module must be installed. ■ Microimager 70 ■ Microimager 70/AFM ❏ Scanner 900 ❏ Scanner 923 ■ Scanner/Microimager 990 ❏ Scanner 9500 1. Select Film Writer. Character Orientation Image Addr Print Format Same Sequence per Level Print Sequence - ...
3-24 A-61097 May 1997 Character Orientation This mode defines the orientation of the information printed by the filmwriter. The default is Comic. ■ Microimager 70 ■ Microimager 70/AFM ❏ Scanner 900 ❏ Scanner 923 ■ Scanner/Microimager 990 ❏ Scanner 9500 1. Select Character Orientation. Character Orie...
A-61097 May 1997 3-25 Image Address Print Format This mode defines the format of the Image Address printed on film.The default is Compress. ❏ Microimager 70 ■ Microimager 70/AFM ❏ Scanner 900 ❏ Scanner 923 ■ Scanner/Microimager 990 ❏ Scanner 9500 1. Select Image Addr Print Format. Character Orientat...
3-26 A-61097 May 1997 Write Definitions This mode defines the information printed on film next to each document,based upon the document level. The default value for all levels is<FF/IA-All Del>. ■ Microimager 70 ■ Microimager 70/AFM ❏ Scanner 900 ❏ Scanner 923 ■ Scanner/Microimager 990 ❏ Scann...
3-28 A-61097 May 1997 Image Management Code NOTE: The Film Writing Module must be installed. ■ Microimager 70 ■ Microimager 70/AFM ❏ Scanner 900 ❏ Scanner 923 ■ Scanner/Microimager 990 ❏ Scanner 9500 1. Select Image Mgmt Code. StatusIMT Search Prg NumberMagnification Splice Definition Image Mark Siz...
3-30 A-61097 May 1997 IMT Search Program Number This mode defines the IMT search program number. The default value is00. ■ Microimager 70 ■ Microimager 70/AFM ❏ Scanner 900 ❏ Scanner 923 ■ Scanner/Microimager 990 ❏ Scanner 9500 1. Select IMT Search Prg Number. StatusIMT Search Prg Number Magnificati...
A-61097 May 1997 3-31 Magnification This mode defines for the KODAK IMAGELINK™ Digital Workstation (withZoom Lens Accessory) the desired level of magnification. The defaultvalue is 20. ■ Microimager 70 ■ Microimager 70/AFM ❏ Scanner 900 ❏ Scanner 923 ■ Scanner/Microimager 990 ❏ Scanner 9500 1. Selec...
3-32 A-61097 May 1997 Splice Definition This mode defines the desired action when a splice is detected. Thedefault value is Ignore. ■ Microimager 70 ■ Microimager 70/AFM ❏ Scanner 900 ❏ Scanner 923 ■ Scanner/Microimager 990 ❏ Scanner 9500 1. Select Splice Definition. Select any of the Sort Criteria ...
A-61097 May 1997 3-33 Image Mark Sizes This mode defines the image mark sizes used (small, medium, and large).The default value is Kodak Standard. ■ Microimager 70 ■ Microimager 70/AFM ❏ Scanner 900 ❏ Scanner 923 ■ Scanner/Microimager 990 ❏ Scanner 9500 1. Select Image Mark Sizes. StatusIMT Search P...
3-34 A-61097 May 1997 Image Polarity This mode defines the polarity of the image marks relative to the polarityof the document images. The default value is Same as Image Mark. ■ Microimager 70 ■ Microimager 70/AFM ❏ Scanner 900 ❏ Scanner 923 ■ Scanner/Microimager 990 ❏ Scanner 9500 1. Select Image P...
A-61097 May 1997 3-35 Duplex Front Location The mode defines for the KODAK IMAGELINK™ Digital Workstationwhere the front side image is located. The default value is Same as IMChannel. ■ Microimager 70 ■ Microimager 70/AFM ❏ Scanner 900 ❏ Scanner 923 ■ Scanner/Microimager 990 ❏ Scanner 9500 1. Select...
3-36 A-61097 May 1997 Film Image Orientation The mode defines where the top of the image is located for theKODAK IMAGELINK™ Digital Workstation. The default value is LeadingEdge Up. ■ Microimager 70 ■ Microimager 70/AFM ❏ Scanner 900 ❏ Scanner 923 ■ Scanner/Microimager 990 ❏ Scanner 9500 1. Select F...
A-61097 May 1997 3-37 Image Offset This mode defines the position of the image marks relative to the leadingedge of the document. The default value is 0. ■ Microimager 70 ■ Microimager 70/AFM ❏ Scanner 900 ❏ Scanner 923 ■ Scanner/Microimager 990 ❏ Scanner 9500 1. Select Image Offset. StatusIMT Searc...
3-38 A-61097 May 1997 Length Monitor NOTE: The Advanced Document Controller must be installed. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Length Monitor. StatusMax Document Length Min Document Length Length Err Response Previo...
3-40 A-61097 May 1997 Maximum Document Length This mode defines the maximum document length accepted. The defaultvalue is 13.000 inches/325 mm. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Max Document Length. StatusMax Document...
A-61097 May 1997 3-41 Minimum Document Length This mode defines the minimum document length accepted. The defaultvalue is 02.500 inches/63 mm. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Min Document Length. StatusMax Document ...
3-42 A-61097 May 1997 Length Error Response This mode defines the action taken if a document is smaller than theminimum length specified or larger than the maximum length specified.The default value is Display and Beep. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Micr...
A-61097 May 1997 3-43 Skew Monitor ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 NOTE: The Advanced Document Controller must be installed. 1. Select Skew Monitor. Skew Detect Status Skew Threshold Skew Error Response Previous Menu Mode Con...
3-44 A-61097 May 1997 Skew Threshold This mode defines the amount of tolerable skew. If 5 Degrees is selected,an error will be reported if the amount of document skew is between 5 and30 degrees. If 10 Degrees is selected, an error will be reported if theamount of document skew is between 10 and 30 d...
A-61097 May 1997 3-45 Skew Error Response This mode defines the action taken if the amount of document skew isgreater than the threshold specified. The default value is Display andBeep. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Sele...
3-46 A-61097 May 1997 Check Stacker NOTE: The Check Stacker must be installed. This mode defines when the check stacker is activated. Continuous willactivate the check stacker whenever the side panel switch is on.Documents in Transport will activate the check stacker only when thereare documents exi...
A-61097 May 1997 3-47 Endorser NOTE: The Endorser must be installed. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Endorser. StatusModePrint Position Previous Menu Mode Configuration Don't Save & End Session End Configuration...
3-48 A-61097 May 1997 Endorser Status Enables or disables the endorser. The default value is Off or Disabled. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Status. StatusMode Print Position Previous Menu Mode Configuration Don't ...
A-61097 May 1997 3-49 Endorser Mode This mode defines whether the endorser will print continually or only onceper document. Continuous will activate the Endorser continually. SingleStamp will activate the Endorser only once per document. The defaultvalue is Continuous. ■ Microimager 70 ■ Microimager...
3-50 A-61097 May 1997 Endorser Print Position This mode defines how far from the leading edge of the document theendorsement will appear: The default value is 0000.250 inch/6.350 mm. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select ...
A-61097 May 1997 3-51 Footswitch Pressed NOTE: The Footswitch accessory must be installed. This mode defines the action which results when the footswitch ispressed. The default is Undefined. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 Wh...
3-52 A-61097 May 1997 Footswitch Released NOTE: The Footswitch accessory must be installed. This mode defines the action which results when the footswitch ispressed. The default is Undefined. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1...
A-61097 May 1997 3-53 Footswitch Confirmation Tone NOTE: The Footswitch accessory must be installed. This mode enables or disables the footswitch press confirmation tone. Thedefault is Off or Disabled. ❏ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scan...
3-54 A-61097 May 1997 Patch Reader 1 NOTE: A Patch Reader accessory or Document Scanning Array must be installed. Enables or disables the primary patch reader. The default value is Off orDisabled. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9...
A-61097 May 1997 3-55 Patch Reader 2 NOTE: A Patch Reader accessories or Document Scanning Array must be installed. Enables or disables the secondary patch reader. The default value is Offor Disabled. ❏ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ❏ Scanner/Microimager 990 ■ Scann...
3-56 A-61097 May 1997 Patch Definition NOTE: At least one Patch Reader accessory or Document Scanning Array must be installed. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Patch Definition. Mode Configuration Don't Save & En...
A-61097 May 1997 3-57 Transfer Patch Definition This mode defines which level should be assigned to the next documentwhen a transfer patch is used. The default value is Level 2. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Trans...
3-58 A-61097 May 1997 Film Transfer Patches This mode defines whether or not a document containing a transfer patchis to be filmed. The default value is Transfer Patch Filmed. ❏ Microimager 70 ■ Microimager 70/AFM ❏ Scanner 900 ❏ Scanner 923 ■ Scanner/Microimager 990 ❏ Scanner 9500 1. Select Film Tr...
A-61097 May 1997 3-59 Patch Recognition This mode defines which patch codes will be recognized by the system.The default value is 2, 3, & T. ❏ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Patch Recognition. Mode Configuration ...
3-60 A-61097 May 1997 Bar Code NOTE: A Bar Code Reader must be installed. ❏ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Bar Code. Mode Configuration Don't Save & End Session End Configuration Save & End Session Previous M...
A-61097 May 1997 3-61 Bar Code Reading Status Enables or disables bar code reading. The default value is Off orDisabled. ❏ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Bar Code Reading Status. Mode Configuration Don't Save & E...
3-62 A-61097 May 1997 Bar Code Type Identifies the type of bar code which is to be read. The default value isCode 39. ❏ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Bar Code Type. Mode Configuration Don't Save & End Session En...
A-61097 May 1997 3-63 Number of Bar Code Characters This mode defines the minimum bar code length allowed (in terms of thenumber of characters encoded). The default value is 3. ❏ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select # of B...
3-64 A-61097 May 1997 Bar Codes per Document This mode defines the number of bar codes per document to be decoded.The default value is One Code. ❏ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Bar Codes per Document. Mode Configura...
A-61097 May 1997 3-65 Distance Between Codes This mode defines the minimum bar code height allowed. The height ofthe tallest bar code determines the distance between codes. The defaultvalue is 1.000 inch/25.400 mm. ❏ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimag...
3-66 A-61097 May 1997 Scan Direction This mode defines whether the bar codes may be read in only onedirection (from left to right) or in either direction (from left to right or fromright to left). The default value is Unidirectional (from left to right only). ❏ Microimager 70 ■ Microimager 70/AFM ■ ...
A-61097 May 1997 3-67 Image Processing Enables or disables image processing; indicates whether or not imageprocessing is required to enhance the overall quality of the bar codesused. The default value is Off or Disabled. ❏ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Mic...
3-68 A-61097 May 1997 Partial Read Enabled Enables or disables partial bar code reading. The default value is Off orDisabled. ❏ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Partial Read Enabled. Mode Configuration Don't Save &...
A-61097 May 1997 3-69 Minimum Partial Characters NOTE: Partial Reading must be enabled or this definition will be ignored. This mode defines the minimum number of characters which must beproperly decoded to constitute a partial read. The default value is 5-80. ❏ Microimager 70 ■ Microimager 70/AFM ■...
3-70 A-61097 May 1997 DSA Patch Reading Status Enables or disables patch reading using the Document Scanning Array.The default value is Off or Disabled. ❏ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select DSA Patch Reading Status. Mode...
A-61097 May 1997 3-71 Patch Horizontal Location This mode defines the position of patches on the document(s) in terms ofthe distance from the left side of the transport. The default value is5.12 inches/130.048 mm. ❏ Microimager 70 ■ Microimager 70/AFM ❏ Scanner 900 ■ Scanner 923 ■ Scanner/Microimage...
3-72 A-61097 May 1997 End Fed Patch Reading Status Enables or disables end fed patch reading using the Document ScanningArray. The default value is Off or Disabled. ❏ Microimager 70 ■ Microimager 70/AFM ❏ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select End Fed Patch Read...
A-61097 May 1997 3-73 Level Change via Bar Code Enables level changes based upon detection of a bar code. The defaultvalue is Undefined. ❏ Microimager 70 ■ Microimager 70/AFM ❏ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Level Change via Bar Code. Mode Configuration ...
3-74 A-61097 May 1997 Confirmation Tones NOTE: The tones must have been enabled during machine configuration; otherwise, these definitions will be ignored. ❏ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Confirmation Tone. Patch De...
A-61097 May 1997 3-75 Patch Detected Tone NOTE: Patch reading must be enabled. In addition, the confirmation tones must have been enabled during machine definitions;otherwise, this definition will be ignored. This mode enables or disables a confirmation tone issued when a patchdocument is detected. ...
3-76 A-61097 May 1997 Bar Detected Tone NOTE: Bar Code reading must be enabled. In addition, during machine definitions the confirmation tones must have been enabled;otherwise, this definition will be ignored. Enables or disables a confirmation tone issued when a bar codedocument is detected. The de...
3-78 A-61097 May 1997 OCR Status NOTE: The OCR accessory must be installed. Enables or disables Optical Character Recognition. The default value isOff or Disabled. ❏ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ❏ Scanner 9500 1. Select OCR Status. Mode Co...
A-61097 May 1997 3-79 COIN User Channel NOTE: If the machine definition User COIN Port Protocol was disabled, these definitions will be ignored. Enables or disables the COIN2 user channel. If a standard form of output was chosen during machine definition (BarCode/KDIS Protocol or OCR Data Protocol),...
3-80 A-61097 May 1997 Transmit Data This mode defines the data output via the COIN2 port when a user-defined protocol (User-Defined KDIS Format or User-Defined Protocol) ischosen during machine definition. The default values are FF/IA for alllevels. ❏ Microimager 70 ■ Microimager 70/AFM ■ Scanner 90...
3-82 A-61097 May 1997 Printer Control NOTE: The Document Printer Controller must be installed ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Printer Control. Printer Control Mode Configuration Don't Save & End Session End Conf...
A-61097 May 1997 3-83 Print Position This mode defines how far from the leading edge of the document(s) theinformation printed by the document printer(s) will appear. The defaultvalue is 00.250 inch/6.25 mm. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ...
3-84 A-61097 May 1997 Special Character Set This mode defines the size font to be printed. Select either the smaller orlarger font size when using the Document Printer 12. The default value isUse Smaller Font. NOTE: This selection is not available if the wrong printer driver board is installed. The ...
A-61097 May 1997 3-85 Primary Document Printer 1 NOTE: A Document Printer 1 accessory must be installed. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Primary DP-1. Primary Document Printer Mode Configuration Don't Save & End...
A-61097 May 1997 3-87 Print Definitions This mode defines the information printed on each document, based uponthe document level. The default values are Nothing Printed for Level 0 documents; Full ImageAddress with all delimiters for Level 1, Level 2, and Level 3 documents<FF/IA All Del>. ■ Mi...
3-90 A-61097 May 1997 Secondary Document Printer 1 NOTE: Two Document Printer 1 accessories must be installed. ❏ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Secondary DP-1. Second Document Printer Mode Configuration Don't Save &a...
3-92 A-61097 May 1997 Fonts/Orientation—DP2 This mode defines the size and orientation of the characters printed by thesecondary Document Printer 1. The default value is Off or Disabled. ❏ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Sel...
A-61097 May 1997 3-93 Print Definitions—DP2 This mode defines the information printed on each document, based uponthe document level. The default values are Nothing Printed for Level 0documents; Full Image Address with all delimiters for Level 1, Level 2, andLevel 3 documents. ❏ Microimager 70 ■ Mic...
A-61097 May 1997 3-95 If Message Number is selected, the following window is displayed: Message Number 1Message Number 2Message Number 3Message Number 4Message Number 5Message Number 6Message Number 7Message Number 8Message Number 9 Previous Menu Message Number Current Print Sequence Display Values ...
3-96 A-61097 May 1997 Document Printer 12 NOTE: The Document Printer 12 accessory must be installed ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Doc. Printer 12. Document Printer 12 Mode Configuration Don't Save & End Sessio...
A-61097 May 1997 3-97 Document Printer Status—DP12 Enables or disables the Document Printer 12. The default value is Off orDisabled. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Document Printer Status. Field PAW 12 Status Docum...
3-98 A-61097 May 1997 Fonts/Orientation—DP12 This mode defines the size and orientation of the characters printed by theDocument Printer 12. The default value is Comic Orientation. ■ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 1. Select Fo...
A-61097 May 1997 3-99 Print Definitions—DP12 This mode defines the information printed on each document, based uponthe document level. The default values are No Print Template for Level 0documents; Print Template for Level 1, Level 2, and Level 3 documents.The default is IA-No Del. ■ Microimager 70 ...
A-61097 May 1997 3-101 Document Sorter OFF ❏ Microimager 70 ■ Microimager 70/AFM ■ Scanner 900 ■ Scanner 923 ■ Scanner/Microimager 990 ■ Scanner 9500 Select Document Sorter and the following screen appears: Status Error ResponseSort Criteria Document Sorter Sort Criteria Don't Save & End Session...
3-102 A-61097 May 1997 If 4 selections have been set and you choose a 5th option, the followingscreen appears: Maximum number of sorting criteria has been reached Press ENTER to proceed… ** ERROR ** Mode Configuration Don't Save & End Session End Configuration Save & End Session Previous Men...
A-61097 May 1997 3-103 Film Definition This mode enables or disables filming. This option is set as follows: Microimager 70 F (film) Scanners 900, 923, 9500 NoF (no film) Scanner/Microimager 990 F (film) ❏ Microimager 70 ❏ Microimager 70/AFM ❏ Scanner 900 ❏ Scanner 923 ■ Scanner/Microimager 990 ❏ Sc...
A-61097 May 1997 4-1 4 Installation Questionnaire General Information CUSTOMER NAME: __________________________________________________________________ CUSTOMER ADDRESS: _______________________________________________________________ __________________________________________________________________...
4-2 A-61097 May 1997 Machine Definitions 0.0 Accessory Status _ _ _ _ _ _ _ _ _ _ _ _ _ Adv. Doc. Controller _ _ _ _ _ _ _ _ _ _ _ _ _ Bar Code Reader _ _ _ _ _ _ _ _ _ _ _ _ _ Doc Scanning Array _ _ _ _ _ _ _ _ _ _ _ _ _ Check Feeder _ _ _ _ _ _ _ _ _ _ _ _ _ Check Stacker _ _ _ _ _ _ _ _ _ _ _ _ _...
A-61097 May 1997 A-1 A PPEN D IX A : S y s t e m M a p Display Machine Accessories Machine ID NumberDisplay Language Measurement SystemProgrammable Function Keys Date Format Time FormatAlarm ToneDoc Printer/Film Writer MsgDP-12 Print Template Fixed Field Delimiter Set System ClockVersion Numbers Use...
† May be executed while transport is running. * Available when filming; for use only with Microimager 70 (with or without AFM), and Scanner/Microimager 990. ** Available when scanning; for use only with the Scanner 900, Scanner 923, Scanner 9500, and Scanner/Microimager 990. *** Available when using...
A-61097 May 1997 C-1 A PPEN D IX C : Recommended Entries Item Description Values 0.0 Accessory Status PRES (Present)NOTPRES (Not Present) 1.0 Machine ID Number 00 – 99 2.0 Display Language ENG (English)FREN (French)GERM (German)ITAL (Italian)SPAN (Spanish) 3.0 MeasurementSystem ENG (English)MET (Met...
Kodak Manuals
-
Kodak KLIC-7005
Manual
-
Kodak KAC-9617
Manual
-
Kodak Z915
Manual
-
Kodak 8049959
Manual
-
Kodak i280
Manual
-
Kodak 5229
Manual
- Kodak ESP 7 Manual
-
Kodak DCS 465
Manual
-
Kodak 1H9659
Manual
-
Kodak 2.5.5
Manual
-
Kodak K700-C+2
Manual
-
Kodak E-2411
Manual
-
Kodak K625
Manual
-
Kodak 630
Manual
-
Kodak i1800
Manual
-
Kodak 7212
Manual
-
Kodak M315DP
Manual
-
Kodak C-41RA
Manual
-
Kodak 3383
Manual
-
Kodak D-32
Manual