Page 3 - Contents; Safety Notes; Drinking Water; Electrical Equipment; Intended Use
WTC 600 LP / MP 3 Safety Notes Version 06/05 Contents Equipment Components 1 Sand filter2 Activated carbon filter3 Control, activated carbon filter4 Control, sand filter5 Manometer, sand filter supply pressure6 Manometer, activated carbon filter supply pressure 7 RO filter unit8 Switch box9 Operatin...
Page 4 - Maintenance and Care; Starting Operation; Admission-pressure Unit; KÄRCHER specialist dealer
WTC 600 LP / MP 4 Maintenance and Care Version 06/05 3 Maintenance and Care 3.1 Starting Operation Before starting operation: • Make sure that the equipment is connected to the untreated water source and the respective transporting gear, e. g., admission-pressure unit. • Ensure the unrestricted flow...
Page 5 - vated carbon filters
WTC 600 LP / MP 5 Maintenance and Care Version 06/05 3.1.3 Switching On the Equipment • Check if the pumps of the metering station, sand and activated carbon filter are connected to the respective power outlets (18 / 19) at the switch box (8). • Check if the operating mode switch (9) is in the corre...
Page 6 - During Operation; Control and Corrective Action Intervals
WTC 600 LP / MP 6 Maintenance and Care Version 06/05 3.2 During Operation 3.2.1 Control and Corrective Action Intervals d…daily, w…weekly, m… monthly 3.2.2 Sand and Activated Carbon Filter During operation, the sand and activated carbon filter control indicates the actual time. To change the indicat...
Page 10 - Completely emptied metering container:; Switching Off the Equipment; Consumption Materials; chlorinated
WTC 600 LP / MP 10 Consumption Materials Version 06/05 (2) Metered Addition The metered addition is carried out dependent of the level in the metering container. Completely emptied metering container: • Fill 10 l of drinking water into the metering con- tainer. • With a measuring cup, measure the 7....
Page 11 - Malfunctions; RO system
WTC 600 LP / MP 11 Malfunctions Version 06/05 5 Malfunctions Malfunctions of the RO system are signaled with LEDs at the control panel (10) and indicated at the display. Malfunctions on the admission-pressure unit are indicated with the red LED (26) on the control unit of the admission-pressure unit...
Page 12 - Technical Data
WTC 600 LP / MP 12 Technical Data Version 06/05 6 Technical Data Parameter WTC 600 LP WTC 600 MP Ambient temperature +1 °C – +50 °C Storage temperature (upon delivery) to –10 °C Humidity <100 % r.F. Supply voltage 3*400 V 50 Hz * 1*230 V 50 Hz * * depending on supply by the customer Pre-filter co...
Page 13 - EU Declaration of Conformity; Water treatment plant
WTC 600 LP / MP 13 EU Declaration of Conformity Version 06/05 7 EU Declaration of Conformity We hereby declare that the equipment described below conforms to the relevant fundamental safety and health requirements of the appropriate EU Directive, both in its basic design and construction as well as ...