Page 2 - TABLE OF CONTENTS; SECTION 1; IMPORTANT SAFETY INSTRUCTIONS; READ AND FOLLOW ALL INSTRUCTIONS.; SAVE THESE INSTRUCTIONS!
TABLE OF CONTENTS CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator SECTION 1 General Information 1A. Description ........................................................... 11B. Specifications ...................................................... 11C. Warranty Summary ........................
Page 3 - General Information; C. Warranty Summary; SECTION 2; Installation
1 CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator SECTION 1 General Information 1A. Description The Infinity™ Corona Discharge series ozone generatordescribed in this manual is designed to provide the ben-efits of ozonated water in an environmentally safe andeffective manner. Infinity™gene...
Page 4 - E. ORP Sensor Connection
2 CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator 2B. Mounting 2B-1. Wall Mount Option 1. Attach two mounting brackets to wall using anchors appropriate for mounting surface. See figure 1. 2. Using 1/4"-20 bolts (with washers as shown) se- cure generator to mounts. 2B-2. Floor Mount Op...
Page 5 - SECTION 3; Operation; C. Normal Operation
2E-2. ORP Cable Routing:Route the cable away from other power wires and protectcable from damage. (i.e. Conduit or attached to plumb-ing.) Connect the sensor cable to the BNC connector lo-cated on the left exterior wall of the generator cabinet. SECTION 3 Operation 3A. General To achieve optimal per...
Page 6 - SECTION 4; Maintenance and Service; B. Preventative Maintenance Schedule
4 CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator SECTION 4 Maintenance and Service 4A. System Electro-Mechanical Overview Refer to Figure 4 for component locations.4A-1. Indicator Lights 1. Main Power: Green light indicates that power is being supplied to the ozone generator. 2. Ozone Pow...
Page 8 - SECTION 5; Replacement Parts and Order Information
6 CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator 2. G.F.C.I. has tripped.* a. Check power cord and reset G.F.C.I. 3. Circuit breaker has tripped.* a. Reset breaker. *If G.F.C.I. or breaker continue to trip after reset, callfor technical assistance. Symptom: “ Ozone power” indicator light ...
Page 9 - LIMITED WARRANTY
7 CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator DEL INDUSTRIES, INC. LIMITED WARRANTY The limited warranty set for th below applies to products manufactured by DEL INDUSTRIES, Inc. - 3428Bullock Lane, San Luis Obispo, California 93401, and sold by DEL INDUSTRIES and its authorized dealer...
Page 10 - APPENDIX “A”
8 CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator APPENDIX “A” SAFETY
Page 11 - HEALTH HAZARDS OF OZONE
9 CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator HEALTH HAZARDS OF OZONE Detection Levels Ozone can be detected in air by its distinctive odor atconcentrations of about 0.02 ppm. Although each nosevaries, olfactory fatigue occurs quickly. As a result, DONOT RELY ON ODOR AS A WARNING OF HI...