IBM Type 1881 - Manuals
IBM Type 1881 – Manual in PDF format online.
Manuals:
Manual IBM Type 1881
Summary
Contents About this manual . . . . . . . . . . . . . . . . . . . . . . . vii Important safety information . . . . . . . . . . . . . . . . . . . . viiOnline support . . . . . . . . . . . . . . . . . . . . . . . . . viiiSupport telephone numbers . . . . . . . . . . . . . . . . . . . . viii Chapter 1. ...
Removing the acoustic module option . . . . . . . . . . . . . . . 41 Installing and removing blade servers . . . . . . . . . . . . . . . . 41 Blade server expansion options . . . . . . . . . . . . . . . . . . 41Installing a blade server . . . . . . . . . . . . . . . . . . . . 43 Removing a blade ser...
Grounding requirements . . . . . . . . . . . . . . . . . . . . 91 Safety notices (multi-lingual translations) . . . . . . . . . . . . . . 91 Appendix C. Notices . . . . . . . . . . . . . . . . . . . . . . 131 Trademarks. . . . . . . . . . . . . . . . . . . . . . . . . . 131Important notes . . . . . ...
About this manual This manual contains diagnostic information, a Symptom-to-FRU index, serviceinformation, error codes, error messages, and configuration information for theBladeCenter ® E Type 8677 and 1881 unit. Important safety information Be sure to read all caution and danger statements in this...
Lea atentamente todas las declaraciones de precaución y peligro ante de llevar acabo cualquier operación. Online support You can download the most current diagnostic, H8 flash, and device driver filesfrom http://www.ibm.com/systems/support on the World Wide Web. Support telephone numbers View suppor...
Chapter 1. General information The IBM ® BladeCenter E Type 8677 and 1881 unit is a high-density, high-performance rack-mounted system developed for medium-to-large businesses.It supports up to 14 blade servers, making it ideally suited for networkingenvironments that require a large number of high-...
The serial number and model number are on labels on the top, front, and rear ofthe chassis, as shown in the following illustration. Note: The illustrations in this document might differ slightly from your hardware. A set of user labels comes with each blade server. Write whatever identifyinginformat...
The IBM Documentation CD Use the IBM Documentation CD to access the blade server documentation in PDFformat. You can run the IBM Documentation CD on any personal computer that meets the hardware and software requirements. The IBM Documentation CD contains documentation for your blade server in Porta...
When you select a document, a description of the document is displayed under Topic Description . To select more than one document, press and hold the Ctrl key while you select the documents. Click View Book to view the selected document or documents in Acrobat Reader or xpdf. If you selected more th...
Notices and statements used in this book The caution and danger statements used in this book also appear in the multilingual Safety Information book provided on the IBM BladeCenter Documentation CD. Each caution and danger statement is numbered for easy reference to the correspondingstatements in th...
Major components of the BladeCenter Type 8677 and 1881 unit The following illustration shows the locations of major components in yourBladeCenter unit. Note: The illustrations in this document might differ slightly from your hardware. Attention: To maintain proper system cooling, each module bay mus...
Front view The following illustration shows the locations of components and indicators on thefront of the BladeCenter Type 8677 and 1881 unit. See “BladeCenter components, controls, and LEDs” on page 13 for details aboutthese components and indicators. Chapter 1. General information 9
Rear view The following illustration shows the locations of components and indicators on therear of the BladeCenter Type 8677 and 1881 unit. See “BladeCenter components, controls, and LEDs” on page 13 for details aboutthese components and indicators. 10 BladeCenter E Type 8677 and 1881: Hardware Mai...
Shutting down the BladeCenter unit You can shut down the BladeCenter unit by turning off the blade servers anddisconnecting the BladeCenter unit from the power source. Complete the following steps to shut down the BladeCenter unit: 1. Refer to your blade server operating-system documentation for the...
BladeCenter components, controls, and LEDs This section identifies the components, controls, and LEDs on the front and rear ofyour BladeCenter unit. Note: The illustrations in this document might differ slightly from your hardware. Front view This section identifies the components, controls, and LED...
The following illustration shows the rear view for the currently available powermodules. Power module LEDs: These LEDs indicate the condition of the power module. For additional information, see “Identifying problems using the Light Path Diagnosticsfeature” on page 29. v AC power: When this green LE...
System LED panel The following illustration shows the status LEDs on the system LED panels on thefront and rear of the BladeCenter unit. Power-on Location Over-temperature Information System error Attention: If the power-on LED is off, it does not mean there is no electrical current present in the B...
Connecting to the default IP address on a new BladeCenter A newly-installed (out-of-the-box) BladeCenter unit tries to locate a DHCP server onthe network before it will default to the factory-configured static IP address in themanagement module. This is the initial configuration setting. When there ...
Chapter 2. Configuring your BladeCenter unit The BladeCenter unit automatically detects the modules and blade servers that areinstalled and stores the vital product data (VPD) information. When the BladeCenterunit is started, it automatically configures the remote-management port on themanagement mo...
v Monitoring the status of the BladeCenter unit and blade servers v Controlling the BladeCenter unit and blade servers v Accessing the I/O modules to configure them v Changing the drive startup sequence in a blade server v Setting the date and time v Using a remote console for the blade servers v Ch...
Notes: 1. All management modules are preconfigured with the same static IP address. You can use the management-module Web interface or command-line interfaceto assign a new static IP address for each BladeCenter unit. If DHCP is notused and you do not assign a new static IP address for each BladeCen...
The IBM Director software includes the IBM BladeCenter Deployment Wizard. About the wizard The BladeCenter Deployment Wizard is integrated into the IBM Directormanagement software. The wizard walks you through initial startup andconfiguration of one or more BladeCenter units. In addition to performi...
MAC MAC MAC 1a 2a 3a1b 2b 3b Switch A MgmtMod Switch B 1 Gbps links 1 Gbps or100 Mbps links 1 Gbps links 10/100 Mbps 100 Mbpslinks Note: 2nd switch module is optional 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Each blade server has two independent Ethernet controllers, each with its ownMAC address and a dedic...
Switch A MgmtMod Switch B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Switch A MgmtMod Switch B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Switch A MgmtMod Switch B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 L2 Switch L2+ Switch L2+ Switch Multiport aggregation group1 Gbps or 100 Mbps links 10/100 Mbpsmanagementlinks Dualexternal...
Chapter 3. Diagnostics This section provides basic troubleshooting information to help you resolve somecommon problems that might occur with your BladeCenter unit. If you cannot locate and correct the problem using the information in this section,see Appendix A, “Getting help and technical assistanc...
Chapter 4. Installing options This chapter provides instructions for adding options to your BladeCenter unit.Some option-removal instructions are provided in case you need to remove oneoption to install another. Installing the BladeCenter unit in a rack Statement 20: CAUTION:To avoid personal injury...
some restrictions, hot-swap blade servers while the BladeCenter unit is running.For complete details about installing or removing a hot-swap component, see thedetailed information in this chapter. v The blue color on components and labels identifies touch points where you cangrip a component, move a...
Installing and removing modules The procedures for installing or removing a module on the BladeCenter unit arenearly identical for all modules except the blower modules. To install or remove ablower module, see “Replacing a blower module” on page 47. To install or removeall other modules, follow the...
I/O (switch) modules For blade server communication with the network, your BladeCenter unit supportsfrom one to four hot-swap I/O modules. Table 1 on page 35 identifies the type of I/Omodule you can install in each I/O-module bay. Go to the IBM Support Web site athttp://www.ibm.com/systems/support t...
The following table summarizes the types of modules that can be used in eachI/O-module bay. See “Rear view” on page 10 for the location of the I/O-module bayson the BladeCenter unit. Table 1. Hot-swap I/O module types by location Bays I/O-module function Permissible I/O module 1 and 2 Network connec...
Power modules Note: The IBM BladeCenter E type 8677 and 1881 chassis must be configured to support 2320-watt power modules. See the IBM BladeCenter E 2320 Watt Power Modules Installation Guide for specific information and instructions. Your BladeCenter unit comes with one pair of 220-volt hot-swap p...
Installing a module The following illustration shows how to install a power module, managementmodule, or I/O module in the rear of the BladeCenter unit. See “Replacing a blowermodule” on page 47 for information about replacing a blower module. Before you begin, read the documentation that comes with...
7. Attach any cables or cords required by the module. See “Input/output connectors” on page 46 for the location of connectors on the BladeCenter unit.Be sure to route the power cord on a power module through the strain-reliefclamp on the power module. 8. Make sure the LEDs on the module indicate tha...
Installing and removing the acoustic module option For server environments where noise reduction is essential, you might choose toinstall the BladeCenter acoustic attenuation module option (acoustic module) on theBladeCenter unit. The acoustic module reduces the sound level of the BladeCenterunit to...
Note: If an I/O expansion option is installed on any blade server, I/O modules for that network interface must be installed in I/O-module bays 3 and 4 on theBladeCenter unit. See “I/O (switch) modules” on page 34 for more information. Storage-expansion option Some blade servers have a connector for ...
Installing a blade server Complete the following steps to install a blade server in the BladeCenter unit. Statement 21: CAUTION:Hazardous energy is present when the blade is connected to the powersource. Always replace the blade cover before installing the blade. 1. Read the “Important safety inform...
Removing a blade server Complete the following steps to remove a blade server from the BladeCenter unit. Attention: v To maintain proper system cooling, do not operate the BladeCenter unit for morethan one minute without either a blade server or a filler blade installed in eachblade bay. If you fail...
Completing the installation After you connect the cables to the modules and route the cables (if necessary, seethe Rack Installation Instructions for information about routing the cables), start the BladeCenter unit (if it is not already started), and verify that it is working properly,as follows: 1...
Chapter 5. Service replaceable units This chapter describes the removal of server components. Important: The field replaceable unit (FRU) procedures are intended for trained servicers who are familiar with IBM products. See the parts listing in Chapter 7,“Parts listing, BladeCenter Type 8677 and 188...
Tabs Slots Lift points Pressure points Reverse these instructions to reinstall the media tray cover. Press the rear of thecover down onto the two fasteners to secure the cover in place. Optical or diskette drive Note: The diskette drive is not present in all BladeCenter unit models. The optical driv...
3. If you are removing the diskette drive, disconnect the cable from the rear of the drive. 4. Slip the wire spring out from under the retention hook, and pull it away from the drive. Set the wire spring aside. 5. Slide the drive out of the front of the media tray, and set it aside. 6. Set any jumpe...
Customerinterface card Fasteners USB connector 3. Disconnect the cables from the customer interface card. 4. Lift the two rear corners of the customer interface card to release it from the fasteners. 5. Slide the customer interface card toward the rear of the media tray until the USB connector is fr...
Midplane Complete the following steps to replace the midplane. Note: v Read “Installation guidelines” on page 31. v Read the safety notices at “Safety information” on page 87. v Read “Handling electrostatic discharge-sensitive devices” on page 90. 1. Shut down the BladeCenter, and remove the SPC cha...
Front system LED panel The front system LED panel is on the customer interface card in the media tray. Toreplace the front system LED panel, replace the customer interface card. See“Customer interface card and USB connector” on page 50 for instructions. 56 BladeCenter E Type 8677 and 1881: Hardware ...
Rear system-LED panel The rear system-LED panel is on the SPC chassis. Complete the following steps toreplace the rear system-LED panel. Note: v Read “Installation guidelines” on page 31. v Read the safety notices at “Safety information” on page 87. v Read “Handling electrostatic discharge-sensitive...
Chapter 6. Symptom-to-FRU index This index supports the BladeCenter Type 8677 and 1881. Notes: 1. Check the configuration before you replace a FRU. Configuration problems can cause false errors and symptoms. 2. For IBM devices not supported by this index, refer to the manual for that device. 3. Blad...
Light Path Diagnostics table The system-error LED on the system LED panel is lit when certain system errorsoccur. If the system-error LED on your BladeCenter unit is lit, use the followingtable to help determine the cause of the error and the action you should take. Table 3. Light Path Diagnostics L...
Power error messages Note: See Chapter 7, “Parts listing, BladeCenter Type 8677 and 1881,” on page 79 to determine which components should be replaced by a field service technician. Message Action Power module 3 or 4 is required topower blades 7 to 14 Ensure power modules 3 and 4 are installed and c...
Note: See Chapter 7, “Parts listing, BladeCenter Type 8677 and 1881,” on page 79 to determine which components should be replaced by a field service technician. Message Action System is under recommended voltagefor +5V 1. Reseat the management module. 2. Replace the management module. System running...
Note: See Chapter 7, “Parts listing, BladeCenter Type 8677 and 1881,” on page 79 to determine which components should be replaced by a field service technician. Message Action Switch module%d IP configuration waschanged Information only. Take action as required. ENET [X] DHCP HSTN=X, DN=X, IP @=XXX....
Note: See Chapter 7, “Parts listing, BladeCenter Type 8677 and 1881,” on page 79 to determine which components should be replaced by a field service technician. Message Action Remote access attempt failed. Invaliduserid or password received. User isXXX from WEB browserIP@=XXX.XXX.XXX.XXX Failed atte...
Note: See Chapter 7, “Parts listing, BladeCenter Type 8677 and 1881,” on page 79 to determine which components should be replaced by a field service technician. Message Action Failure reading I2C device. Checkdevices on bus 5. 1. Reseat the I/O modules. 2. Reseat the management module. 3. Replace th...
Note: The front and rear panel LEDs will not function with the media tray removed. 3. Move the power module to bay 2. 4. Remove and reconnect the power cord to the power module. 5. Replace the management module. 6. Replace the power module. 7. Replace the midplane. Problem determination tips Due to ...
Appendix A. Getting help and technical assistance If you need help, service, or technical assistance or just want more informationabout IBM products, you will find a wide variety of sources available from IBM toassist you. This section contains information about where to go for additionalinformation...
You can find service information for IBM systems and optional devices athttp://www.ibm.com/systems/support/. Software service and support Through IBM Support Line, you can get telephone assistance, for a fee, with usage,configuration, and software problems with System x and xSeries servers,BladeCent...
Appendix B. Related service information Note: The service procedures are designed to help you isolate problems. They are written with the assumption that you have model-specific training on all computers,or that you are familiar with the computers, functions, terminology, and serviceinformation prov...
Electrical safety CAUTION:Electrical current from power, telephone, and communication cables can behazardous. To avoid personal injury or equipment damage, disconnect theattached power cords, telecommunication systems, networks, and modemsbefore you open the server covers, unless instructed otherwis...
v Do not use worn or broken tools and testers. v Never assume that power has been disconnected from a circuit. First, check that it has been powered-off. v Always look carefully for possible hazards in your work area. Examples of thesehazards are moist floors, nongrounded power extension cables, pow...
3. Check the power cord for: a. A third-wire ground connector in good condition. Use a meter to measure third-wire ground continuity for 0.1 ohm or less between the external groundpin and frame ground. b. The power cord should be the appropriate type as specified in the parts listings. c. Insulation...
Grounding requirements Electrical grounding of the computer is required for operator safety and correctsystem function. Proper grounding of the electrical outlet can be verified by acertified electrician. Safety notices (multi-lingual translations) The caution and danger safety notices in this secti...
Instrução 1 PERIGO A corrente elétrica proveniente de cabos de alimentação, de telefone e decomunicações é perigosa. Para evitar risco de choque: v Não conecte ou desconecte cabos e não realize instalação, manutenção oureconfiguração deste produto durante uma tempestade com raios. v Conecte todos os...
Instrução 2 CUIDADO: Ao substituir a bateria de lítio, utilize apenas uma bateria IBM, Número de Peça33F8354 ou uma bateria de tipo equivalente, recomendada pelo fabricante. Se oseu sistema possui um móídulo com uma bateria de lítio, substitua-o apenas pelomesmo tipo de mídulo, do mesmo fabricante. ...
Luokan 1 Laserlaite 106 BladeCenter E Type 8677 and 1881: Hardware Maintenance Manual and Troubleshooting Guide
Notice n° 1 DANGER Le courant électrique passant dans les câbles de communication, ou les cordonstéléphoniques et d'alimentation peut être dangereux. Pour éviter tout risque de choc électrique: v Ne manipulez aucun câble et n'effectuez aucune opération d'installation,d'entretien ou de reconfiguratio...
Notice n° 2 ATTENTION: Remplacez la pile au lithium usagée par une pile de référence identiqueexclusivement - voir la référence IBM - ou par une pile équivalenterecommandée par le fabricant. Si votre système est doté d'un modulecontenant une pile au lithium, vous devez le remplacer uniquement par un...
Notice n° 4 ≥ 18 kg (37 lbs) ≥ 32 kg (70.5 lbs) ≥ 55 kg (121.2 lbs) ATTENTION: Faites-vous aider pour soulever ce produit. Notice n° 5 ATTENTION: Le bouton de mise sous tension/hors tension de l'unité et l'interrupteurd'alimentation du bloc d'alimentation ne coupent pas l'arrivée de courantélectriqu...
Hinweis 1 VORSICHT Elektrische Spannungen von Netz-, Telefon- und Datenübertragungsleitungen sindgefährlich. Aus Sicherheitsgründen: v Bei Gewitter an diesem Gerät keine Kabel anschließen oder lösen. Ferner keineInstallations-, Wartungs- oder Rekonfigurationsarbeiten durchführen. v Gerät nur an eine...
Hinweis 2 ACHTUNG: Eine verbrauchte Batterie nur durch eine Batterie mit der IBM Teilenummer33F8354 oder durch eine vom Hersteller empfohlene Batterie ersetzen. Wenn IhrSystem ein Modul mit einer Lithium-Batterie enthält, ersetzen Sie es immer mit demselben Modultyp vom selben Hersteller. Die Batter...
Avviso 1 PERICOLO La corrente elettrica circolante nei cavi di alimentazione, del telefono e di segnale èpericolosa. Per evitare il pericolo di scosse elettriche: v Non collegare o scollegare i cavi, non effettuare l'installazione, la manutenzione ola riconfigurazione di questo prodotto durante i te...
Avviso 2 ATTENZIONE: Quando si sostituisce la batteria al litio, utilizzare solo una batteria IBM con numeroparte 33F8354 o batterie dello stesso tipo o di tipo equivalente consigliate dalproduttore. Se il sistema di cui si dispone è provvisto di un modulo contenente unabatteria al litio, sostituire...
Declaración 1 PELIGRO La corriente eléctrica de los cables telefínicos, de alimentaciín y de comunicacioneses perjudicial. Para evitar una descarga eléctrica: v No conecte ni desconecte ningún cable ni realice las operaciones de instalaciín,mantenimiento o reconfiguraciín de este producto durante un...
Declaración 2 PRECAUCIÓN: Cuando desee sustituir la batería de litio, utilice únicamente el número de pieza33F8354 de IBM o cualquier tipo de batería equivalente que recomiende elfabricante. Si el sistema tiene un mídulo que contiene una batería de litio,sustitúyalo únicamente por el mismo tipo de m...
Declaración 4 ≥ 18 kg ≥ 32 kg ≥ 55 kg PRECAUCIÓN: Tome medidas de seguridad al levantar el producto. Declaración 5 PRECAUCIÓN: El botín de control de alimentaciín del dispositivo y el interruptor de alimentaciín dela fuente de alimentaciín no apagan la corriente eléctrica suministrada aldispositivo....
Appendix C. Notices This information was developed for products and services offered in the U.S.A. IBM may not offer the products, services, or features discussed in this document inother countries. Consult your local IBM representative for information on theproducts and services currently available...
Adobe and PostScript are either registered trademarks or trademarks of AdobeSystems Incorporated in the United States and/or other countries. Cell Broadband Engine is a trademark of Sony Computer Entertainment, Inc., in theUnited States, other countries, or both and is used under license therefrom. ...
Some software might differ from its retail version (if available) and might not includeuser manuals or all program functionality. Electronic emission notices Federal Communications Commission (FCC) statement Note: This equipment has been tested and found to comply with the limits for a Class A digit...
This product has been tested and found to comply with the limits for Class AInformation Technology Equipment according to CISPR 22/European Standard EN55022. The limits for Class A equipment were derived for commercial and industrialenvironments to provide reasonable protection against interference ...
Power cords For your safety, IBM provides a power cord with a grounded attachment plug to usewith this IBM product. To avoid electrical shock, always use the power cord andplug with a properly grounded outlet. IBM power cords used in the United States and Canada are listed by Underwriter'sLaboratori...
IBM Manuals
-
IBM SC41-5210-04
Manual
-
IBM TM7
Manual
-
IBM 8677
Manual
-
IBM EM78P809N
Manual
-
IBM 610
Manual
-
IBM AIX 4.3
Manual
-
IBM 8128
Manual
-
IBM PANEL1173-841
Manual
-
IBM L150
Manual
-
IBM E50
Manual
-
IBM 8319
Manual
-
IBM DS3300
Manual
-
IBM 9519-AG1
Manual
-
IBM 6.00E+04
Manual
-
IBM PD78082(A)
Manual
-
IBM S544-5343-03
Manual
-
IBM PPC-1510PT
Manual
-
IBM 37L1388
Manual
-
IBM V2.3
Manual
-
IBM DS4500
Manual