Page 3 - Table of Contents
3 Table of Contents Important Information ....................................... 5Tools ................................................................. 6 Uninstalling the Existing Unit ............................ 9 Installing the Thermostat ................................ 12Installing the wall ...
Page 5 - IMPOrTAnT InFOrMATIOn
5 This thermostat is designed to work on the following heating and cooling systems: Gas – Standing Pilot Gas – Electronic Ignition Gas – Fired Boilers Gas – Millivolt Systems Oil – Fired Boilers Oil – Fired Furnace Electric Furnace This thermostat is not designed for heat pump systems or 110/220 V b...
Page 6 - TOOlS
6 This thermostat includes two #8 slotted screws and two wall anchors for mounting. To install your new thermostat, you will need the following supplies: Flat-head screwdriver ...................................................................................... Small Phillips-head screwdriver ........
Page 9 - (Some thermostats may have multiple covers, screws; UnInSTAllInG THE ExISTInG UnIT
9 1. Turn the system power OFF from the existing thermostat. Turn the power to the HVAC system OFF at the main power panel or at the furnace. 2. remove the existing thermostat cover to access the wires from the wall. (Some thermostats may have multiple covers, screws or other locking devices that mu...
Page 10 - * See page 27 for complete wiring diagram.
10 If your existing thermostat is marked... label the wire with this sticker: rH / r / Vr / 4 rH rH 24 Volt W / H W W heating G / F G G fan * See page 27 for complete wiring diagram.
Page 12 - InSTAllInG THE THErMOSTAT
12 InSTAllInG THE THErMOSTAT InSTAllInG THE THErMOSTAT 1. remove the new thermostat from the back plate by pulling the two halves apart. Thermostat Wall Plate
Page 14 - InSTAllInG THE WAll PlATE
14 2. Position the new wall plate on the wall and pull the labeled wires through the opening. 3. If the existing holes do not match those on the Hunter wall plate, or if there are no existing holes, level the wall plate and mark the wall for two holes. 4. remove the wall plate and drill two 3/16” ho...
Page 21 - OPErATIOn; , The fan will be turned on along with normal
21 OPErATIOn 1. Set the s Et t EmpEraturE slidEr to the desired temperature. 2. The s ystEm s witcH determines the operating mode of the thermostat. Select O ff or H Eat . 3. The f an s witcH should normally be located in the a utO position. To run the fan continuously, slide the f an s witcH to the...
Page 22 - InDICATOrS AnD ADUSTMEnT
22 InDICATOrS AnD ADUSTMEnT 1. The t HErmOmEtEr indicates the room temperature. 2. The B attEry i ndicatOr displays two stages of w Eak B attEry w arninG , indicated by the B attEry i ndicatOr flashing once approximately every second. When this warning appears, install two fresh AA alkaline batterie...
Page 23 - Span Adjust; SPAN
Page 24 - F. The Span setting remains; to turn the
24 InDICATOrS AnD ADjUSTMEnTS, COnT. 1. remove the thermostat from the wall plate. 2. To make your system run lOnGEr, turn the s pan a djust clockwise. 3. To make your system run SHOrTEr, turn the s pan a djust counter clockwise. 4. reattach the thermostat to the wall plate. note: The Span range is ...
Page 25 - My heating or cooling will not turn on or off.; a. Check the HE/HG switch to ensure it is set to the correct; My system continues to operate when the
25 1. My heating or cooling will not turn on or off. 1 a. Check the HE/HG switch to ensure it is set to the correct position. 1 b. Check the circuit breakers and switches to ensure there is enough power to the system. 1 c. replace the batteries with fresh AA alkaline batteries. 1 d. If applicable, m...
Page 26 - Sure. Our Technical Support Group is available from 8 am; TrOUBlESHOOTInG
26 Is there help on the web? Yes. Visit http://www.hunterfan.com for more information. .................................................................................... ......... Can’t I just call someone? Sure. Our Technical Support Group is available from 8 am to 5 pm CST. They may be reached t...
Page 27 - WIrInG DIAGrAMS; Rh; Rh W
27 WIrInG DIAGrAMS Rh W Heat 24V or Millivolt Supply Heat Relay or Valve 2-wire Heat Only System G Rh W Heat 24V Supply Heat Relay or Valve 3-wire Heat Only System Fan Relay