Heat & Glo XLR-PLUS-PB-AU - Manuals
Heat & Glo XLR-PLUS-PB-AU – Manual in PDF format online.
Manuals:
Manual Heat & Glo XLR-PLUS-PB-AU
Summary
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 2 MODELS: XLR-PLUS-N-AU, XLR-PLUS-PB-AU ARE SAI GLOBAL APPROVED FOR NATURAL GAS, PROPANE OR BUTANE AS A BALANCED FLUE HEATER. Refer to the appliance data plates for gas consumptions and pressures.Installation of this appliance s...
3 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on fireplace: _____________________ Dealership purchased f...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 4 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 6 AUSTRALIAN WARRANTY INFORMATION Warranty information in the attached manual is for international markets, not Australia. For Australian warranty information, please see below. Hearth & Home Technologies Inc (HHT) 7571 215t...
7 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 Warranty Period Heat & Glo Manufactured Appliances and Venting Components Covered Parts Labor Gas Wood Pellet EPA Wood Coal Electric Venting 5 years 1 years X X Castings & baffl es 7 years 3 years X X X Manifold tubs H...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 8 • Non Heat & Glo venting components, hearth components or other accessories used in conjunction with the appliance. • Any part of a pre-existing fi replace system in which an insert or a decorative gas appliance is install...
9 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 A. Appliance Certification C. High Altitude Installations NOTICE: If the heating value of the gas has been reduced, these rules do not apply. Check with your local gas utility or authorities having jurisdiction. When installin...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 10 Figure 2.1 General Operating Parts B. Your Fireplace WARNING! DO NOT operate fireplace before read - ing and understanding operating instructions. Failure to operate fireplace according to operating instructions could cause f...
11 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 C. Clear Space WARNING! DO NOT place combustible objects in front of the fireplace or block louvers. High temperatures may start a fire. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hear...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 12 I. Lighting Instructions (IPI) The IPI system may be operated with four C-cell batteries. When using batteries, unplug the transformer. To prolong battery life, remove them when using the transformer. 1. This appliance is equ...
13 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 J. Control Module Operation 1. The control module has an ON/OFF/REMOTE selector switch that must be set. OFF Position: Appliance will ignore all power inputs and will not respond to any commands from a wall switch or optional...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 14 K. After Fireplace is Lit Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • Turn the fireplace off and allow it to completely cool.• Remove fixed glass assembly. See Section ...
15 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 Glass Cleaning Frequency: Seasonally By: Homeowner Tools Needed : Protective gloves, glass cleaner, drop cloth and a stable work surface. CAUTION! Handle fixed glass assembly with care. Glass is breakable. • Avoid striking, s...
17 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 A. Typical Appliance System NOTICE: Illustrations and photos reflect typical installations and are for design purposes only. Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual Figur...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 18 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No addit...
19 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 5 Framing and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1). WARNING! Risk of Fire or Burns! Provide adequ...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 20 B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should enclosed inside the chase. NOTICE: Treatment of ceilin...
21 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 D. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clear - ances to combustibles as specified. Framing or finishing material closer than the minimums listed must be construct- ed entirely of noncomb...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 22 A. Vent Termination Minimum Clearances H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING VERTICAL WALL TERMINATION CAP HORIZONTAL OVERHANG 305 mm X ROOF PITCH IS X/ 305 mm LOWEST DISCHARGE OPENING 510 mm MIN. 61...
23 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 Figure 6.3 Minimum Clearances for Termination NOTES: 1. All distances are measured vertically or horizontally along the wall to a point in line with the nearest part of the terminal. 2. Prohibited area below electricity meter...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 24 A. Approved Pipe This appliance is approved for use with Hearth & Home Technologies SLP venting systems. Refer to Section 17.B for vent component information. DO NOT mix pipe, fittings or joining methods from differ- ent ...
25 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 Figure 7.3 Top Vent - Horizontal Termination Venting with 1 elbow H 1 V 1 V Minimum H 1 Maximum 90 Elbow 457 mm 305 mm (1 ft.) 914 mm (3 ft.) 457 mm (1.5 ft.) 1067 mm (3.5 ft.) 610 mm (2 ft.) 1.52 m (5 ft.) 762 mm (2.5 ft.) 1...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 26 INSTALLED HORIZONTALLY H 1 H 2 V 1 Figure 7.4 1. Top Vent - Horizontal Termination - (continued) Top Vent - Horizontal Termination Venting with 2 elbows Note : Use SLP Series components only. V Minimum H 1 + H 2 Maximum 90° E...
27 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 Figure 7.5 Vertical Vent Maximum Note : If installing a vertical vent/termination off the top of the appliance, the optional exhaust restrictor may be needed. V 1 V 1 Max= 13.4 m ( 44 ft.) Top Vent - Vertical Termination No E...
31 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). • SLP heat shield - designed to be used on a wall 4-3/8 in. to 7-5/8 in. (111 mm to 194 mm) thick. • If wall thickness is less than 4-3/8 in. (111 mm) the exi...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 32 C. Install the Ceiling Firestop A ceiling firestop MUST be used between floors and attics.• SLP pipe only - Frame opening 9 in. x 9 in. (229 mm x 229 mm) whenever the vent penetrates a ceiling/floor (see Figure 8.3). • Frame ...
33 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 D. Install Attic Insulation Shield WARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home Technologies Inc. requires the use of an attic shield. Attic shields must meet specified clear...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 34 ELBOW HEAT SHIELD SHOWN IN SHIPPING POSITION CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. A. Top Vent 9 Appliance Preparation...
35 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 B. Securing and Leveling the Appliance WARNING! Risk of Fire! Prevent contact with: • Sagging or loose insulation • Insulation backing or plastic • Framing and other combustible materialsBlock openings into the chase to preve...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 36 10 Installing Vent Pipe (SLP Pipe) Figure 10.2 High Temperature Silicone Sealant A. Assemble Vent Sections To attach the first vent component to the starting collars of the appliance:• Lock the vent components into place by s...
37 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 C. Secure The Vent Sections • Vertical runs of pipe must be supported every 8 ft. (2.44 m).• Horizontal sections must be supported every 5 ft. (1.52 m). • Vent supports or plumbers strap (spaced 120º apart) may be used to sup...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 38 D. Disassemble Vent Sections • Rotate either section (see Figure 10.7) so the seams on both pipe sections are aligned as shown in Figure 10.8. • Pull carefully to separate the pieces of pipe. Figure 10.8 Align and Disassemble...
39 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 F. Install Metal Roof Flashing • See minimum vent heights for various pitched roofs (Figure 10.11) to determine the length of pipe to extend through the roof. • Slide the roof flashing over the pipe sections extending through...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 40 SCREWS CAULK STORM COLLAR (1 of 3) Figure 10.15 TERMINATION CAP H. Install Vertical Termination Cap • Attach the vertical termination cap by sliding the inner collar of the cap into the inner flue of the pipe section while pl...
41 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 K. Install Horizontal Termination Cap WARNING! Risk of Fire! The telescoping flue section of the termination cap MUST be used when connecting vent. • 1-1/2 in. (38 mm) minimum overlap of flue telescoping section is required. ...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 42 11 Gas Information A. Gas Pressure Requirements Pressure requirements for XLR-PLUS-AU fireplaces are shown in Table 11.1 below.Two taps are provided on the front face of the gas control for a test gauge connection to measure ...
43 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 CHECK FOR GAS LEAKSExplosion RiskFire RiskAsphyxiation Risk• Check all fittings and connections.• Do not use open flame.• After the gas line installation is complete, all connections must be tightened and checked for leaks wi...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 44 C. Optional Accessories Requirements • This appliance may be used with a wall switch, wall mounted thermostat and/or a remote control, and module reset switch. Wiring for optional Hearth & Home Technologies approved acces...
45 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 D. Junction Cord Information The junction cord is installed at the factory. Refer to Figure 12.2 and 12.3. for more information. E. Electrical Service and Repair WARNING! Risk of Shock! Label all wires prior to dis- connectio...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 46 G. Control Module Operation 1. The control module has an ON/OFF/REMOTE selector switch that must be set. See Figure 12.4. OFF Position: Appliance will ignore all power inputs and will not respond to any commands from a wall s...
47 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 FCC Requirements WARNING! Risk of Fire! Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: This equipment has b...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 48 5. Close the housing door. See Figure 12.8. 4. Place remote control inside housing. See Figure 12.7. Figure 12.7 Remote in Housing Figure 12.8 Mounting Remote Control Housing AUX300CE Module Installation • Insert the 4 hole h...
49 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 FIREPLACE STATUS THERMOSTAT THERMOSTAT DESIRED TEMP SETTING FLAME HEIGHT FAN SPEED ADJUSTABLE AUXILIARY ADJUSTABLE OUTPUT (ON/OFF) TIMER DISPLAY/FUNCTION ROOM TEMP DISPLAY FUNCTION LEVEL INDICATOR LOW BATTERY INDICATOR TRANSM...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 50 About ON Mode • All functions can be accessed when the remote control is in the ON mode. • Only active functions will be displayed when the remote control is in the ON mode. For example: if the fan is the only function that’s...
51 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 Adjusting Thermostat • Press the MENU button to activate the menu. • Using the UP and DOWN arrows highlight the THERMO icon and press SELECT . • Use the UP and DOWN arrows to turn the THERMO ON or OFF , then press SELECT (the...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 52 Frequently Asked Questions/Troubleshooting Symptom Possible Cause Corrective Action Remote control will not transmit Batteries Verify batteries are functional and installed correctly. Remote control is in Child Lock mode Dise...
53 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 13 Finishing A. Framing and Finishing Instructions WARNING! Risk of Fire! Comply with all minimum clear - ances to combustibles as specified. Framing closer than the minimums listed must be constructed entirely of noncom- bus...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 54 WARNING! Risk of Fire! Maintain specified air space clearances to combustibles. Failure to comply with these instructions may cause a fire or cause the appliance to overheat. LOWER COVER PANEL TOP FLANGE FINISHING FLANGES SID...
55 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 Note: The lower cover panel must be pushed all the way down. The outer finishing flanges should line up. The fireplace opening must be between 15-3/4 in. (400 mm) and 16-1/8 in. (410 mm) for the decorative fronts to fit corre...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 56 B. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clear - ances to combustibles as specified. Framing closer than the minimums listed must be constructed entirely of noncom- bustible materials (i.e...
57 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 C. Facing Material • Facing and/or finishing materials must not interfere with air flow through louvers, operation of louvers or doors, or access for service. • Facing and/or finishing materials must never overhang into the g...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 58 Non-Combustible Finish Material 0 - 1 in. (25 mm) Thick Bottom Joint 3/4 in. (19 mm) 3 in. (76 mm) 3/4 in. (19 mm) Figure 13.11 Noncombustible Surface Finishing Material 0 - 1 in. (25 mm) Thick-Inside Fit Method (Tonic Decora...
59 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 Figure 13.14. Dimensions of Tonic Decorative Front. A B D C E F TONIC FRONT Table 1. Dimensions of Tonic Decorative Front. A Top of decorative front to bottom of appliance. 26-3/8 in. (670 mm) B Bottom of decorative front to ...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 60 A. Remove Fixed Glass Assembly See Section 14.E. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the firebox. The standard black rock media and manual bag assembly are also shipped underne...
61 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 Figure 14.3 Air Shutter G. Air Shutter Setting Air shutter settings may be adjusted by a qualified install- er at the time of installation. The air shutter is set at the factory for minimum vertical vent run. Adjust air shutt...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 62 A. IntelliFire Plus™ Ignition System Symptom Possible Cause Corrective Action 1. Pilot won’t light. The ignitor/module makes noise, but no spark. a. Incorrect wiring. Verify “S” wire (white) for sensor and “I” wire (orange) f...
65 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 16 Component Access WARNING! Risk of Fire, Electric Shock and Burns! Turn off power to module and valve by unplugging the 6V transformer from the junction cord, before removing fixed glass assembly. A. Decorative Front and Fi...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 66 Figure 16.5 Remove Valve Plate Screws 3. Set the valve bracket on the front lip of the firebox bot- tom. Turn “off” the ball valve. Disconnect gas valve from the gas flex ball valve assembly at the pressure fitting. See Figur...
67 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 G. Gas Valve Replacement Once the valve assembly has been removed, the gas valve, pilot assembly, orifice flex tube, and flex ball valve can be replaced. 1. Place the valve assembly on a clean, stable surface to service or re...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 68 17 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5. A B G Q C L D E H O F P N Ø I J K M S R GAS L...
69 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 B. Maintenance Tasks Inspect Maintenance Tasks Doors 1. Inspect for scratches, dents or other damage and repair as necessary.2. Verify no obstructions to airflow.3. Verify maintenance of proper clearance to combustible househ...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 70 Cap Shield DRC-RADIUS 13-7/8 in. (352 mm) 9-1/2 in (241 mm) 14 in. (356 mm) COOL-ADD Cap Shield 11-5/8 in. (295 mm) 5-3/4 in. (146 mm) 7-1/8 in (181 mm) 12-1/8 (308 mm) DVP-BEK2 DVP-HPC Cap Brick Extension 13-7/8 in. (352 mm)...
71 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 8-1/2 in. (222 mm) 6-1/2 in. (165 mm) 6-5/8 in. (168 mm) 8-3/4 in. (152 mm) 6-1/2 in (165 mm) 6-5/8 in. (168 mm) 9-7/8 in (251 mm) 6-1/2 in. (165 mm) 9-1/4 in. (235 mm) SLP-45 - 45° Elbow SLP90- 90° Elbow Effective Height/ Le...
73 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 SLP-TRAP Horizontal Termination Cap 15-1/8 in. (384 mm) Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be used on a wall 4 in. (102 mm) to 7-1/4 in. (184 mm) thick. If wall t...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 74 D. Service Parts XLR-PLUS-N-AU, XLR-PLUS-PB-AU Landscape Heater Rated Appliance Beginning Manufacturing Date: May 2011 Ending Manufacturing Date: ______ IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replace...
75 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 15.1 15.2 15.3 15.4 15.5 15.6 15.7 15.8 15.9 15.10 15.11 15.12 15.13 15.15 15.14 15.16 15.17 Service Parts XLR-PLUS-N-AU, XLR-PLUS-PB-AU IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for y...
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 76 XLR-PLUS-N-AU, XLR-PLUS-PB-AU D. Service Parts List IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this...
77 Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 Heat & Glo, a brand of Hearth & Home Technologies Inc. 7571 215th Street West, Lakeville, MN 55044 www.heatnglo.com E. Contact Information Please contact your Heat & Glo dealer with any questions or concerns. For ...
Heat & Glo Manuals
-
Heat & Glo SL-550TV-IPI-E
Manual
-
Heat & Glo CF750ENH
Manual
-
Heat & Glo ST-HV-IPI
Manual
-
Heat & Glo 6000GLX-IPILP-S/-R
Manual
-
Heat & Glo st-42tvfl
Manual
-
Heat & Glo 7000XLS
Manual
-
Heat & Glo 8000TV-OAK-IPI
Manual
-
Heat & Glo EM-415 - 36
Manual
-
Heat & Glo 350TRSILP-AUF
Manual
-
Heat & Glo Exclaim-50
Manual
-
Heat & Glo 6000 Series
Manual
-
Heat & Glo XLR-PLUS-N-AU
Manual
-
Heat & Glo 8000CFLP-OAKIPI
Manual
-
Heat & Glo BE-41C
Manual
-
Heat & Glo VRT-GY-P-AUB
Manual
-
Heat & Glo 6000CL-IPI-S
Manual
-
Heat & Glo ST-36TRLP-IPI
Manual
-
Heat & Glo SL-550TV-D
Manual
-
Heat & Glo 6000GL-IPILP-S
Manual
-
Heat & Glo BW36