Page 2 - PLEASE READ THIS MANUAL BEFORE INSTALLING; before leaving the installation site.
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 2 MODELS: Supreme-N-I30AU, Supreme-P-I30AU ARE SAI GLOBAL APPROVED FOR NATU- RAL GAS AND PROPANE AS A BALANCED FLUE HEATER. Refer to the appliance data plates for gas consumptions and pressures.Installation of this appliance ...
Page 3 - Listing Label Information/Location; Owner’s Manual; Homeowner Reference Information; Read this manual before installing or operating this appliance.; SAMPLE
3 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on fireplace: ______...
Page 4 - Safety Alert Key:; Indicates a hazardous situation which, if not avoided will; Table of Contents; User Guide; Installation Preparation; 2 Appliance Setup
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 4 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious inj...
Page 5 - B. Limited Lifetime Warranty; AUSTRALIAN WARRANTY INFORMATION; All Parts and Material Except
5 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 B. Limited Lifetime Warranty AUSTRALIAN WARRANTY INFORMATION Warranty information in the attached manual is for international markets, not Australia. For Australian warranty information, please see below. Hearth & Home ...
Page 7 - charges for parts; This warranty is void if:; cracking and discoloration of steel or enamel fi nishes.; HOW TO CLAIM; you originally purchased the product.; Melbourne; Perth; Fireplace Corner; Sydney; Jetmaster
7 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 • Non Heat & Glo venting components, hearth components or other accessories used in conjunction with the appliance. • Any part of a pre-existing fi replace system in which an insert or a decorative gas appliance is inst...
Page 8 - A. Appliance Certification; Listing and Code Approvals; SAI Global; C. High Altitude Installations; If the heating value of the gas has been reduced,; D. Non-Combustible Materials Specification; Standard Test Method for Behavior of Materials in a; E. Combustible Materials Specification; B. Gas Pressure Requirements; Risk of Explosion!; Natural Gas
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 8 A. Appliance Certification 1 Listing and Code Approvals MODELS: Supreme-N-I30-AU, Supreme-P-I30-AU LABORATORY: SAI Global TYPE: Gas Space Heating Appliance STANDARD: AS4553-2008 C. High Altitude Installations NOTICE: If the...
Page 9 - Operating Instructions; DO NOT operate fireplace before read; A. Gas Fireplace Safety; WARNING; HOT SURFACES
9 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 2 Operating Instructions Figure 2.1 General Operating Parts B. Your Fireplace WARNING! DO NOT operate fireplace before read - ing and understanding operating instructions. Failure to operate fireplace according to operating...
Page 10 - Install ONLY doors, fronts or; Batteries should only be used as a power source
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 10 C. Clear Space WARNING! DO NOT place combustible objects in front of the fireplace or block louvers. High temperatures may start a fire. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or h...
Page 11 - I. Before Lighting Fireplace; have a; ate fireplace with fixed glass assembly removed.; Module Reset; Risk of Explosion! DO NOT; Nine Hour Safety Shutdown Feature
11 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 4. If you intend to use both an optional wired wall switch and the RC300 remote control to operate your fireplace, the wall switch will override any commands given by the remote. Note: If the module is in LOCK-OUT mode, re...
Page 12 - battery life, remove them when using the transformer.; LIGHTING; NOT FOR USE; WHAT TO DO IF YOU SMELL GAS; DO NOT CONNECT LINE VOLT-; Also Certified for Installation in a; Final inspection by
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 12 J. Lighting Instructions (IPI) The IPI system may be operated with four AA-cell batteries. When using batteries, unplug the transformer. To prolong battery life, remove them when using the transformer. 1. This appliance is...
Page 13 - K. After Appliance is Lit; ISSUE
13 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 Initial Break-in Procedure• The appliance should be run three to four hours continuously on high. • Turn the appliance off and allow it to completely cool.• Remove fixed glass assembly. See Section 12.H.• Clean fixed glass...
Page 14 - Glass Cleaning; Tools Needed; CAUTION! Handle fixed glass assembly with care.; Note; Maintenance and Service; The appliance should be; Tools needed; Remote Control
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 14 Glass Cleaning Frequency: Seasonally By: Homeowner Tools Needed : Protective gloves, glass cleaner, drop cloth and a stable work surface. CAUTION! Handle fixed glass assembly with care. Glass is breakable. • Avoid striking...
Page 15 - DO NOT
15 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 B. Maintenance Tasks-Service Technician The following tasks must be performed by a qualified technician. Gasket Seal and Glass Assembly Inspection Frequency: Annually By: Service Technician Tools needed: Protective gloves,...
Page 16 - A. Typical Appliance System; drawn to scale. Actual product may vary from pictures in manual; Getting Started; Installer Guide
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 16 A. Typical Appliance System NOTICE: Illustrations and photos reflect typical installations and are for design purposes only. Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual VE...
Page 17 - Read all of the instructions before starting the instal; Risk of Fire or Explosion!; C. Tools and Supplies Needed; Any such action may cause a fire hazard.; NOT
17 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 B. Design and Installation Considerations Heat & Glo gas inserts are designed for installations into solid fuel masonry or factory built fireplaces that have been installed in accordance with the National, Provin- cial...
Page 18 - Fireplace Size Requirements; A. Minimum Fireplace Opening; Risk of Fire or Burns!; RECOMMENDED
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 18 5 Fireplace Size Requirements A. Minimum Fireplace Opening Minimum fireplace opening requirements for a standard 3/4 inch deep surround are shown in Figure 5.2. For smaller openings, an optional 1-1/2 in. (38 mm) deep surr...
Page 19 - TOP VIEW
19 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 Figure 5.2 Fireplace Opening In addition to these dimensions, also reference Clearances and Mantel Projections (Section 5.B). B A G E D C F TOP VIEW SIDE VIEW FRONT VIEW MINIMUM FIREPLACE SIZE (3/4 IN. (19 mm) Surround Dep...
Page 20 - B. Mantel and Wall Projections; Comply with all minimum clear; Location
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 20 B. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clear - ances to combustibles as specified. Framing or finishing material closer than the minimums listed must be construct- ed entirely of nonc...
Page 21 - A. Vent Termination Minimum Clearances; Termination Locations; DO NOT
21 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 A. Vent Termination Minimum Clearances 6 Termination Locations Fire Risk.Maintain vent clearance to combustibles as specified.• DO NOT pack air space with insulation or other materials. Failure to keep insulation or other ...
Page 22 - Installation Preparation; A. Inspection and Cleaning; This fireplace has been con
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 22 7 Installation Preparation Prepare the existing solid fuel masonry or factory built non-combustible firebox for installation. A. Inspection and Cleaning Prior to installing the gas insert:• Have the chimney and adjacent st...
Page 23 - B. Venting Components; Wear protective gloves and safety glasses during instal-; Installing Vent Pipe and Appliance; C. Connecting Vent Pipe; Do; Description
23 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 B. Venting Components CAUTION! Risk of Cuts/Abrasions/Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. The vertical vent termination system installed on this mode...
Page 24 - • Trim chimney top plate to minimize excess overhang or
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 24 Figure 8.2 CUT AND BEND FLASHING AS NEEDED TO FIT CHIMNEY SEALANT ADHESIVE • Trim chimney top plate to minimize excess overhang or bend over flue tile (see Figure 8.2). • Place 3/8 in. (10 mm) bead of 149 ºF (300 ºF) silic...
Page 25 - D. Placing, Securing and Leveling the
25 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 Figure 8.4 REAR LEVELING LEGS SHIPPED IN THIS POSITION LOCATION A REAR LEVELING LEGS MAY BE RELOCATED TO LOCATION A OR LOCATION B LOCATION B WARNING! Risk of Fire! Only an approved Hearth & Home Technologies surround m...
Page 26 - E. Installing Adaptor and Termination Cap; amper Flashing Kit; Masonry
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 26 E. Installing Adaptor and Termination Cap For installation of termination cap see minimum vent heights for various pitched roofs (see Figure 8.5). To install adaptor see Figure 8.8. Angle H (Min.) mm 0°-26.6° ................
Page 28 - F. Vent Kits Components; G. Alternate Venting Configurations Using; NO OTHER FLUE SYSTEMS OR COMPONENTS; This gas appliance
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 28 F. Vent Kits Components Direct Vent Flex Liner Accessory Kits (see Figure 8.9).LINK-DV30B: Masonry 3 in. (76 mm) flex liner kit. Expands to 30 ft. (9 m). Includes: two liners, termination cap, flashing, and link adapter.Fl...
Page 29 - Risk of Fire, Explosion or Asphyxiation!; I. Heat Shield Requirements for; the termination cap must be; For Horizonta; Cap Specification Chart
29 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 Important Notice: Heat shields may not be field constructed. 120º Figure 8.12 Securing Horizontal Pipe Sections • Horizontal sections must be supported every 5 ft. (1.52 m).• Wall shield firestops may be used to provide ho...
Page 30 - Colinear to Coaxial Adapter
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 30 11-7/8 in. (600 mm) MAXIMUM SLP 90° BEND LINK ADAPTER 225 & 275 Ø GALVANIZED FLUE STARTER PLATE FLEXIBLE FLUE MIN. 35-7/16 ft. (900 mm) 10 ft. (3 m) MINIMUM SLP-TRAP Figure 8.13 Optional SLP venting configuration - Hor...
Page 36 - Gas Information; A. Gas Pressure Requirements; GAS VALVE
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 36 9 Gas Information A. Gas Pressure Requirements Pressure requirements for Supreme-N-I30AU and Su- preme-P-I30AU fireplaces are shown in table below.Two taps are provided on the front of the gas control for a test gauge conn...
Page 37 - Electrical Information; A. Wiring Requirements; Ignition System Wiring; Risk of Shock or Explosion! DO NOT
37 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 Figure 10.1 IPI Wiring Diagram RC300AU 10 Electrical Information A. Wiring Requirements NOTICE: This appliance must be installed by a qualified electrician in accordance with the relevant national and local regulations. • ...
Page 38 - C. Optional Accessories Requirements; Label all wires prior to dis-
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 38 Figure 10.2 Fan Wiring Diagram C. Optional Accessories Requirements • This appliance may be used with a wall switch, wall mounted thermostat and/or a remote control. • To connect optional accessories, the supplied cord as-...
Page 39 - Introduction
39 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 D. REM300-HNG-AU Instructions Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions:• Installation and use of any damaged system component.• Modification...
Page 40 - Installation of Remote Control Housing; install damaged or; Changing Temperature Scale; FCC Requirements; Changes or modifications to
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 40 5. Close the housing door. See Figure 10.6. 4. Place remote control inside housing. See Figure 10.5. Figure 10.5. Remote in Housing Installation of Remote Control Housing CAUTION! Risk of Fire! DO NOT install damaged or mo...
Page 41 - AUX300CE Module Installation; CONTROL MODULE; Programming the RC300AU to the Control Module; DO NOT program the remote; FAN CORD
41 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 Figure 10.6. Mounting Remote Control Housing AUX300CE Module Installation • Insert the 4 hole harness from the AUX300CE module into the 4 pin plug on the control module. See Figure 10.7. Fan Installation • Insert the 3 pro...
Page 42 - Function Buttons; For example: Flame Height will not; Idle When Remote is in ON Mode
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 42 FIREPLACE STATUS THERMOSTAT THERMOSTAT DESIRED TEMP SETTING FLAME HEIGHT FAN SPEED ADJUSTABLE AUXILIARY ADJUSTABLE OUTPUT (ON/OFF) TIMER DISPLAY/FUNCTION ROOM TEMP DISPLAY FUNCTION LEVEL INDICATOR LOW BATTERY INDICATOR TRA...
Page 43 - Whenever the fan is turned ON, the FAN will start
43 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 About ON Mode • All functions can be accessed when the remote control is in the ON mode. • Only active functions will be displayed when the remote control is in the ON mode. For example: if the fan is the only function tha...
Page 44 - Adjusting Thermostat; OFF wall switch, it should be in the OFF position when; Adjusting Timer; Battery polarity must be correct or module; Manual Fireplace Shutoff
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 44 Adjusting Thermostat • Press the MENU button to activate the menu. • Using the UP and DOWN arrows highlight the THERMO icon and press SELECT . • Use the UP and DOWN arrows to turn the THERMO ON or OFF , then press SELECT (...
Page 45 - Frequently Asked Questions/Troubleshooting; Symptom
45 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 Frequently Asked Questions/Troubleshooting Symptom Possible Cause Corrective Action Remote control will not transmit Batteries Verify batteries are functional and installed correctly. Remote control is in Child Lock mode D...
Page 46 - Finishing; A. Mantel and Wall Projections
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 46 11 Finishing A. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clear - ances to combustibles as specified. Framing or finishing material closer than the minimums listed must be construct- ed ent...
Page 47 - Appliance Setup; A. Remove Glass Assembly; Risk of Fire and Electric Shock!; E. Place the Lava Rock
47 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 12 Appliance Setup A. Remove Glass Assembly See Section 12.H. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the firebox. C. Clean the Appliance Clean/vacuum any sawdust that may have ...
Page 48 - G. Install the Log Assembly; Bend the log tab into the upright position as shown in; MATE SLOT WITH LOG PIN
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 48 G. Install the Log Assembly Log Set Assembly: LOGS-I30 Models: Supreme-I30, Supreme-I30-SP, Supreme-I30AU, Supreme-I30-C CAUTION: Logs are fragile, handle with care. Log #1 (SRV2206-701): Bend the log tab into the upright ...
Page 49 - corner contacts the log tab.; FORK OF THE LOG
49 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 Log #3 (SRV2206-702) : Position Log #3 as shown in Figure 5. Position the grate tine groove, located on the bottom of the log, over the base of the left grate tine. Pull the log forward. The back end of Log #3 rests on the...
Page 50 - I. Air Shutter Setting; If sooting occurs, provide more air by opening; H. Fixed Glass Assembly; Risk of Asphyxiation!; Removing Fixed Glass Assembly; Air Shutter Settings
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 50 I. Air Shutter Setting Air shutter settings should be adjusted by a qualified ser- vice technician at the time of installation. The air shutter is set at the factory for minimum vertical vent run. Adjust air shutter for lo...
Page 51 - J. Decorative Fronts and Surrounds; REQUIRED TO COMPLETE INSERT INSTALLATION; All fronts come standard with safety mesh
51 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 J. Decorative Fronts and Surrounds REQUIRED TO COMPLETE INSERT INSTALLATION Surround for DF, Flush Fit Front only SI30-4027DF-BK Surround, 40-1/8 x 27-1/8 x 1 in. deep - Black 1020 x 690 x 25 mm deep - Black Surrounds- for...
Page 52 - K. Optional Accessories; Firebox Refractory Upgrade; Optional RC300AU Remote
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 52 K. Optional Accessories Firebox Refractory Upgrade BRICK-SI30 Refractory kit - traditional brick pattern Mantels by Fireside Furnishings Recommendations - Selections In FSF Section Wood St. Cloud, Covington, Bennington she...
Page 53 - Troubleshooting; arrange a service call by a qualified technician.; A. IntelliFire PlusTM Ignition System
53 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 13 Troubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualified tech...
Page 55 - B. Maintenance Tasks; Inspect
55 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 B. Maintenance Tasks Inspect Maintenance Tasks Doors 1. Inspect for scratches, dents or other damage and repair as necessary.2. Verify no obstructions to airflow.3. Verify maintenance of proper clearance to combustible hou...
Page 56 - Reference Materials; A. Appliance Dimension Diagram; MODEL DIMENSIONS
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 56 14 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. Figure 14.1 Appliance Dimensions MODEL DIMENSIONS Location SUPREME-I30-AU Inches Millimeters A 20-3/...
Page 57 - Beginning Manufacturing Date: Feb 2011; 0” Metal Insert, IPI; Log Set Assembly; ITEM
57 Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 B. Service Parts SUPREME-N-I30AU, SUPREME-P-I30AU Beginning Manufacturing Date: Feb 2011 Ending Manufacturing Date: ______ 30” Metal Insert, IPI Log Set Assembly IMPORTANT: THIS IS DATED INFORMATION. When requesting servic...
Page 60 - C. Contact Information; For the location of your nearest Heat & Glo dealer,; DO NOT DISCARD THIS MANUAL; NOTICE
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/12 60 Heat & Glo, a brand of Hearth & Home Technologies Inc. 7571 215 th Street West, Lakeville, MN 55044 www.heatnglo.com C. Contact Information Please contact your Heat & Glo dealer with any questions or concerns. ...