Page 2 - Listing Label Information/Location; This owner ’s manual; Homeowner Reference Information; Read this manual before installing or operating this appliance.; Serial Number; NA; XXXXXXXX
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ L...
Page 3 - Safety Alert Key:; • NOTICE: Used to address practices not related to personal injury.; Table of Contents; User Guide
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could re...
Page 6 - This warranty is void if:; QRWOLPLWHGWRLPSURSHUFKLPQH\RUYHQWLQJLQVWDOODWLRQ; LIMITATIONS OF LIABILITY:; DWLRQRIJODVV
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 6 B. Limited Lifetime Warranty (continued) 4021-645C 12-29-10 Page 2 of 2 WARRANTY CONDITIONS: 7KLVZDUUDQW\RQO\FRYHUV++7DSSOLDQFHVWKDWDUHSXUFKDVHGWKURXJKDQ++7DXWKRUL]HGGHDOHURUGLVWULEXWRU$OLVWRI ...
Page 7 - NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.; Listing and Code Approvals; TYPE: Direct Vent Gas Appliance Heater; Models
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 7 B. Tempered Glass Specifi cations Hearth & Home Technologies appliances manufactured with tempered glass may be installed in hazardous loca-tions such as bathtub enclosures as defi ned by the...
Page 8 - T h e f o l l o w i n g r e q u i r e m e n t s r e f e r e n c e va r i o u s
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 8 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for re...
Page 9 - Operating Instructions; Figure 2.1 General Operating Parts; A. Gas Fireplace Safety; WARNING; HOT SURFACES; touch glass until it is cooled
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 9 2 2 Operating Instructions Figure 2.1 General Operating Parts B. Your Fireplace WARNING! DO NOT operate fi replace before read-ing and understanding operating instructions. Failure to operate fi ...
Page 10 - Figure 2.4 Clear Space; have a; Figure 2.2 Blower Location; Figure 2.3 Rheostat Attachment Tab Location
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 10 D. Clear Space WARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.4. Avoid placing candles and other heat-se...
Page 11 - NOT FOR USE; Final inspection by
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 11 I. Lighting Instructions (IPI) The IPI system may be operated with two D-cell batteries. When using batteries, unplug the transformer. To prolong battery life, remove them when using the transfo...
Page 12 - ISSUE; Condensation on the glass
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 12 Initial Break-in Procedure • T h e f i r e p l a c e s h o u l d b e r u n t h r e e t o f o u r h o u r s continuously on high. • Turn the fi replace off and allow it to completely cool. • Remo...
Page 13 - Glass Cleaning; Tools Needed; Maintenance and Service; Tools needed; Remote Control
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 13 Glass Cleaning Frequency: Seasonally By: Homeowner Tools Needed : Protective gloves, glass cleaner, drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care. Glass i...
Page 15 - Figure 3.1 IPI Pilot Flame Patterns; Burner Ignition and Operation; DO NOT
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 15 Figure 3.1 IPI Pilot Flame Patterns Burner Ignition and Operation Frequency: Annually By: Qualifi ed Service Technician Tools needed: Protective gloves, vacuum cleaner, whisk broom, fl ashlight,...
Page 16 - Getting Started; A. Typical Appliance System; Figure 4.1 Typical System; Dual venting c onf igurations; ARE NOT; b e ve nt e d; E I T H E R; ve r t i c a l l y; O R; Installer Guide
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 16 4 4 Getting Started A. Typical Appliance System NOTICE: Illustrations and photos refl ect typical installations and are for design purposes only. Illustrations/diagrams are not drawn to scale. A...
Page 17 - Read all of the instructions before starting the instal-; C. Tools and Supplies Needed; • Installation and use of any damaged appliance or vent; Any such action may cause a fi re hazard.
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 17 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases ex...
Page 18 - Framing and Clearances; A. Selecting Appliance Location; Figure 5.1 Appliance Locations
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 18 5 5 Framing and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1). WARNING! Ris...
Page 19 - B. Constructing the Appliance Chase; • Insulation and other materials must be secured to prevent; Inches
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 19 C A B D B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should enclosed inside...
Page 21 - See-Through Combustible Mantel; D. Mantel and Wall Projections; Dimensions of Combustibles; Dimensions of Non-Combustibles
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 21 Note: All measurements in inches. MEASUREMENTS FROM TOP EDGE OF THE OPENING TO CEILING 5 10 11 12 2-1/2 13 14 15 16 17 18 19 32 9 10 11 12 8 7 6 5 4 3 25 18 MA X. MIN. See-Through Combustible Ma...
Page 22 - Clearance from opening to perpendicular wall.
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 22 TOP VIEW 3-1/4 in. Min. 2-3/4 in. Min. 1/2 in. Min. Unlimited 1 in.Max. FIREPLACE OPENING Note: Clearance from opening to perpendicular wall. Figure 5.10 Non-Combustible Zone (PIER and ST) Figur...
Page 23 - A. Vent Termination Minimum Clearances; Roof Pitch; Termination Locations; pack air space with insulation or other; Gas, Wood or Fuel Oil
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 23 A. Vent Termination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0*Over 6/12 to 7/12 .........................................
Page 24 - Figure 6.3 Minimum Clearances for Termination; public; Covered Alcove Applications; NOT
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 24 Figure 6.3 Minimum Clearances for Termination O N P R Q X = AIR SUPPLY INLET A = 12 inches.................clearances above grade, veranda, porch, deck or balcony B = 12 inches.................c...
Page 25 - mix pipe, fi ttings or joining methods from differ-; Vent Information and Diagrams; D. Measuring Standards; • Pipe measurements are shown using the effective length; Figure 7.2 DVP Pipe Effective Length; Effective; Horizontal
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 25 A. Approved Pipe This appliance is approved for use with Hearth & Home Technologies a DVP or SLP venting system. Refer to Section 16.B for vent component information. DO NOT mix pipe, fi tti...
Page 26 - After; Reference Figure 7.14 for
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 26 To replace the fi rst starter elbow with two 45° elbows, refer to Figure 7.3. All other 90° elbows can be replaced with two 45° elbows. General Rules: • A maximum of three 90° elbows (or six 45°...
Page 27 - Elbow only; Elbow only
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 27 H 1 V 1 Figure 7.4 Figure 7.5 One Elbow Two Elbows INSTALLED HORIZONTALLY H 1 H 2 V 1 1. Top Vent - Horizontal Termination - (continued) V 1 Minimum H 1 Maximum Elbow only 1-1/2 ft. 457 mm 6 in....
Page 28 - Three Elbows
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 28 Figure 7.6 1. Top Vent - Horizontal Termination - (continued) Three Elbows H 2 H 1 V 2 V 1 V 1 Minimum H 1 Maximum V 2 Minimum H 2 Maximum V 1 + V 2 Minimum H 1 + H 2 Maximum Elbow only 1 ft. 30...
Page 29 - No Elbow; If installing a vertical vent/; Exhaust restrictor Instructions; Remove refractory panel and exhaust baffl e from pilot
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 29 Refractory Panel To access the exhaust opening, remove the refractory panel and exhaust baffle. To remove refractory panel, remove the two screws on top. To remove the exhaust baffle, remove the...
Page 30 - Restrictor; Note; BREAK
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 30 Figure 7.10 4. Center the exhaust restrictor in the open end of the exhaust outlet and secure through the slots on the exhaust restrictor with the 2-1/4 in. self tapping screws provided in the a...
Page 31 - Maximum; One Elbow; ELBOW ONLY
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 31 Figure 7.11 Two Elbows H 1 V 2 V 1 Three Elbows INSTALLED HORIZONTALLY H 1 H 2 V 2 V 1 Figure 7.12 V 1 H 1 Maximum V 2 V 1 + V 2 Minimum One Elbow 2-1/2 ft. 762 mm * * * 2 ft. 607 mm 6 ft. 1.8 m...
Page 32 - use a 45o elbow
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 32 3. Rear Vent - Horizontal Termination Figure 7.13 Figure 7.14 No Elbow One 45° Elbow H 1 = 16 in. (406 mm) Maximum H 1 H 1 DO NOT use a 45º elbow in corner installations. Use two 90º elbow inste...
Page 33 - Two Elbows
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 33 INSTALLED HORIZONTALLY H 3 H 2 V 1 H 1 3. Rear Vent - Horizontal Termination - (continued) Two Elbows Figure 7.15 Figure 7.16 Three Elbows H 2 V 1 H 1 H 1 Maximum V 1 Minimum H 2 Maximum H 1 + H...
Page 34 - Back to Back 90° Elbows
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 34 4. Rear Vent - Vertical Termination One Elbow Figure 7.17 Two Elbows Figure 7.18 V 1 H 1 INSTALLED HORIZONTALLY H 2 V 2 H 1 V 1 Minimum H 1 Maximum 1 ft. 305 mm 3 ft. 914 mm 2 ft. 610 mm 5 ft. 1...
Page 35 - *No specifi c restrictions on this value EXCEPT
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 35 4. Rear Vent - Vertical Termination - (continued) Three Elbows Figure 7.19 Three Elbows Figure 7.20 INSTALLED HORIZONTALLY H 3 H 2 V 1 H 1 V 2 V 1 H 2 H 1 H 1 H 2 H 3 V 1 Minimum H 1 + H 2 + H 3...
Page 36 - A. Pipe Clearances to Combustibles; Vent Clearances and Framing; B. Continue Adding Vent Components; elbow in the venting system.
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 36 A. Pipe Clearances to Combustibles WARNING! Risk of Fire! Maintain air space clearance to vent. DO NOT pack insulation or other combustibles: • Between ceiling fi restops• Between wall shield fi...
Page 37 - Figure 8.5 Wall Penetration; C. Wall Penetration Framing; Combustible Wall Penetration; CORRECT; When terminating horizontally off the top of the unit
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 37 Figure 8.5 Wall Penetration * Shows center of vent framing hole for top or rear venting. The center of the hole is one (1) inch (25.4 mm) above the center of the horizontal vent pipe. C D A* B* ...
Page 38 - D. Vertical Penetration Framing; Figure 8.7 Installing the Attic Shield; ATTIC ABOVE; A ceiling fi restop; MUST; be used between; DVP pipe only; • Frame the area with the same sized lumber
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 38 D. Vertical Penetration Framing Figure 8.6 Figure 8.7 Installing the Attic Shield 3 FASTENERS PER SIDE INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIREST...
Page 39 - E. Install Attic Insulation Shield; Flat Ceiling Installation; Figure 8.8 Attic Insulation Shield; Vaulted Ceiling Installation
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 39 E. Install Attic Insulation Shield WARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home Technologies Inc. requires the use of an attic shield. The Nati...
Page 40 - Appliance Preparation; Cut the metal retaining band and fold the sides
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 40 CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal-lation. Sheet metal edges are sharp. NOTICE: Once appliance is set up for top or rear v...
Page 42 - C. Securing and Leveling the Appliance; LCOR or RCOR; Figure 9.11 Securing An Appliance; Once appliance is setup for top or rear venting, it; Figure 9.10 Proper Positioning and Leveling of an Appliance; Figure 9.9 Attach Nailing Tab to Front Corner of Unit
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 42 C. Securing and Leveling the Appliance WARNING! Risk of Fire! Prevent contact with: • Sagging or loose insulation• Insulation backing or plastic• Framing and other combustible materials Block op...
Page 43 - Attach Vent to the Firebox Assembly; The end of the pipe sections with the lanced tabs will face; Figure 10.1 High Temperature Silicone Sealant; Make sure that the seams are not aligned to prevent; INCORRECT; Lances
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 43 10 10 Installing Vent Pipe (DVP and SLP Pipe) A. Assemble Vent Sections (DVP Pipe Only) Attach Vent to the Firebox Assembly Note: The end of the pipe sections with the lanced tabs will face towa...
Page 44 - Figure 10.5 Adding Venting Components; C. Assemble Slip Sections; Figure 10.6 Slip Section Pilot Holes; Pilot hole; • Apply a bead of silicone sealant inside the female outer
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 44 B. Assemble Vent Sections (SLP Pipe Only) To attach the fi rst vent component to the starting collars of the appliance: • Attach a DVP-2SL adapter to the starting collar of the appliance. • Lock...
Page 45 - E. Disassemble Vent Sections; Figure 10.11 Align and Disassemble Vent Sections
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 45 120º Figure 10.8 Securing Vertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections E. Disassemble Vent Sections • Rotate either section (see Figure 10.10) so the seams on both p...
Page 46 - F. Install Decorative Ceiling Components
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 46 F. Install Decorative Ceiling Components (SLP only) A decorative ceiling thimble can be installed on a fl at ceil-ing through which the vent passes. The decorative ceiling thimble is used to cov...
Page 47 - G. Install Metal Roof Flashing; Opening; H. Assemble and Install Storm Collar; Figure 10.16 Assembling the Storm Collar; CAULK
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 47 G. Install Metal Roof Flashing • See minimum vent heights for various pitched roofs (Figure 10.14) to determine the length of pipe to extend through the roof. • Slide the roof fl ashing over the...
Page 48 - I. Install Vertical Termination Cap; • Slide the decorative wall thimble over the last section of; Heat shields may not be fi eld constructed.; K. Heat Shield Requirements for Horizontal; • DO NOT remove the heat shields attached to the
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 48 SCREWS CAULK STORM COLLAR (1 of 3) Figure 10.18 Figure 10.18 TERMINATION CAP I. Install Vertical Termination Cap • Attach the vertical termination cap by sliding the inner collar of the cap into...
Page 49 - L. Install Horizontal Termination Cap (DVP
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 49 Cap Specifi cation Chart (depth without using additional pipe sections) 36 inch Multisided Series DVP-TRAPK1 Top Vent Depth DVP-TRAP1 Rear Vent Depth DVP-TRAPK2 Top Vent Depth DVP-TRAP2 Rear Ven...
Page 50 - • Purge should be performed by; Gas Information; Gas Pressure; • If substituting for these components, please consult; D. High Altitude Installations
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 50 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home Technologies specifi ed ...
Page 51 - Electrical Information
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 51 A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-l...
Page 53 - Figure 12.3 Junction Box Detail; Figure 12.4 Junction Box Wired to Wall Switch; E. Junction Box Installation; INSIDE
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 53 F. Wall Switch Installation for Fan (Optional) If the box is being wired to a wall mounted switch for use with a fan (See Figure 12.4): • The power supply for the appliance must be brought into ...
Page 54 - Finishing; Figure 13.4 Installation of Splatter Guard; To install the Splatter Guard:
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 54 13 13 Finishing Step 4. Center the splatter guard in front of the unit as shown in Figure 13.3. Place the splatter guard in the unit by guiding the top fl ap into proper position and then con-ti...
Page 56 - B. Mantel and Wall Projections; See-Through Mantel Projection
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 56 Note: All measurements in inches. MEASUREMENTS FROM TOP EDGE OF THE OPENING TO CEILING 5 10 11 12 2-1/2 13 14 15 16 17 18 19 32 9 10 11 12 8 7 6 5 4 3 25 18 MA X. MIN. See-Through Mantel Project...
Page 57 - D. Finishing Material; Stop fi nishing material fl ush with opening.; Finishing materials 1 inch maximum thick.
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 57 Figure 13.16 Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening) TOP VIEW 3-1/4 in. Min. 2-3/4 in. Min. 1/2 in. Min. Unlimited 1 in.Max. FIREPLACE OPENING Note: Clea...
Page 58 - Finishing materials over 1 inch thick.; Figure 13.22 Pier Door Finishing
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 58 Figure 13.20 Inside fi t door Figure 13.21 Operable hinge door DOOR FINISHING MATERIAL FINISHING MATERIAL (Outside door width) (Includes 1/8 in. opening each side of door) 37 in. 37-1/4 in. Fini...
Page 59 - E. Elevated Hearth Systems
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 59 E. Elevated Hearth Systems Use the table below to identify the hearth system that will be used. The table will also help identify effects on the various dimensions. Some hearth systems will elev...
Page 60 - Appliance Setup; E. Lava Rock and Glowing Ember Placement; Placing the Ember Material; Figure 14.1 Placement of Embers
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 60 A. Remove Fixed Glass Assembly See Section 14G. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox. C. Clean the Appliance Clean/vacuum any sawdust...
Page 61 - F. Install the Log Assembly; Figure 1. Log Assembly Location; Follow these instructions to position; PILOT; end of Log #1 onto the smooth area on top of Log C.; HUMP
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 61 F. Install the Log Assembly Figure 2. Factory Installed Logs Figure 2. Factory Installed Logs F Figure 1. Log Assembly Location igure 1. Log Assembly Location CAUTION: DO NOT reposition logs tha...
Page 62 - smooth area on top of the end of log C.; the bottom of log # 3 with the indentations on Log D and the top of Log #2.; GRATE TINES
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 62 F Figure 5. Placement of Log #2 igure 5. Placement of Log #2 2 2 F Figure 7. Placement of Log #3 igure 7. Placement of Log #3 3 3 2 2 INDENTATIONS INDENTATIONS STEP 3. Log #2 (SRV2128-705): The ...
Page 63 - I. Air Shutter Setting; This should be adjusted by a; Figure 14.4 Air Shutter; G. Fixed Glass Assembly; Air Shutter Settings; H. Install Trim Kits and Surrounds; Removing Fixed Glass Assembly; NG
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 63 I. Air Shutter Setting This appliance has an adjustable air shutter (which con-trols the primary air) factory set for the minimum vertical vent run (see Figure 12.15). If your installation has m...
Page 64 - Troubleshooting; A. Intellifi re Ignition System; Symptom
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 64 15 15 Troubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting gui...
Page 65 - a. A shorted or loose connection in fl ame
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 65 Intellifi re Ignition System - (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite. (If the pilot continues to spark af...
Page 66 - Reference Materials; A. Appliance Dimension Diagram; Figure 16.1 See-Through Dimensions; Location Inches
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 66 16 16 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5. Figure 16.1...
Page 67 - Figure 16.2 Pier Dimensions
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 67 Figure 16.2 Pier Dimensions B C FRONT VIEW RIGHT VIEW LEFT VIEW A P L Ø K D M O N E ELECTRICAL ACCESS GAS LINE ACCESS J Ø K F G H i Location Inches Millimeters I 1-1/2 38 J 27 686 K 8 203 L 12 3...
Page 68 - Figure 16.3 LCOR, RCOR Dimensions
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 68 Figure 16.3 LCOR, RCOR Dimensions B C FRONT VIEW RIGHT VIEW ELECTRICAL ACCESS GAS LINE ACCESS LEFT VIEW A J Ø K L Ø K D F G H M P N i O E Location Inches Millimeters I 1-1/2 38 J 27 686 K 8 203 ...
Page 69 - B. Vent Components Diagrams; Figure 16.4 DVP vent components; Assembled
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 69 B. Vent Components Diagrams Figure 16.4 DVP vent components 10-1/2 in.(267 mm) 10-7/8 in. (276 mm) 45 ° 7-3/8 in. (187 mm) 11-3/8 in.(289 mm) 1-1/4 in. (32 mm) 9-1/4 in. (235 mm) 13-1/4 in.(337 ...
Page 70 - Horizontal Termination Cap; Max; The heat shield is designed to be; Heat; Figure 16.5 DVP vent components
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 70 DVP-HPC1 DVP-HPC2 DVP-TRAP1 DVP-TRAP2 DVP-TRAPK2 DVP-TRAPK1 DVP-TRAP Horizontal Termination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST ov...
Page 71 - Figure 16.6 DVP vent components
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 71 13-1/4 in. (367 mm) 24-5/8 in. (625 mm) 27-1/2 in. (127 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in. (625 mm) 13-1/4 in. (367 mm) RF12M Roof Flashing Multi-pak BEK Trap Cap Brick ...
Page 73 - Figure 16.8 Vent Components; Optional Wire Harness; Power Vent Inline
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 73 B. Vent Components Diagrams (continued) Figure 16.8 Vent Components 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) DVP-HRC-SS Optional Wire Harness DESCRIPTION PART NUMBER 10 ft. PV Wire Har...
Page 74 - Figure 16.9 SLP Series Vent Components; Effective Height/Length; Horizontal Pipe
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 74 B. Vent Components Diagrams (continued) Figure 16.9 SLP Series Vent Components EFFECTIVE HEIGHT/ LENGTH 8-3/4 in.222 mm 6-1/2 in.165 mm 6-5/8 in.168 mm 6 in. 152 mm 6-1/2 in.165 mm 6-5/8 in.168 ...
Page 75 - Figure 16.10 SLP Series Vent Components
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 75 B. Vent Components Diagrams (continued) Figure 16.10 SLP Series Vent Components SLP-SNKD Snorkel Termination Cap SLP-TVHW Vertical Termination Cap SLP-CCS-BK Cathedral Ceiling Support Box-Black ...
Page 76 - ITEM; Log Set Assembly; 6” See Through Direct Vent Gas Fireplace
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 76 C. Service Parts ST-36TRB-IPI Beginning Manufacturing Date: Nov. 2008 Ending Manufacturing Date:______ IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your...
Page 77 - 6” Pier Direct Vent Fireplace
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 77 IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordere...
Page 78 - 6” Left Corner Direct Vent Fireplace
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 78 C. Service Parts LCOR-36TRB-IPI Beginning Manufacturing Date: Nov. 2008 Ending Manufacturing Date:______ IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for yo...
Page 79 - 6” Right Corner Direct Vent Fireplace
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 79 C. Service Parts RCOR-36TRB-IPI Beginning Manufacturing Date: Nov. 2008 Ending Manufacturing Date: ______ IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for y...
Page 80 - Service Parts
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 80 IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordere...
Page 81 - C. Service Parts List
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 81 IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordere...
Page 82 - D. Contact Information; For the location of your nearest Heat & Glo dealer,; DO NOT DISCARD THIS MANUAL; NOTICE; • Leave this manual with
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. H • 8/11 82 Heat & Glo, a brand of Hearth & Home Technologies Inc. 7571 215 th Street West, Lakeville, MN 55044 www.heatnglo.com D. Contact Information Please contact your Heat & Glo dealer with...