Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on fireplace: _____________________ Dealership ...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • CAUTION! Indicates a...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 6 4021-645C 12-29-10 Page 2 of 2 WARRANTY CONDITIONS: • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of HHT authorized dealers is available on the HHT branded websites. • This warra...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 7 C. BTU Specifications MODEL: RED60 LABORATORY: Underwriters Laboratories, Inc. (UL) TYPE: Vented Gas Fireplace Heater STANDARD: ANSI Z21.88b-2008 CSA 2.33a-2008 Vented Gas Fireplace Heaters This product is listed to ANSI standards for “Vented Gas Fir...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 8 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated b...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 9 Figure 2.1 General Operating Parts/Clear Space. B. Your Fireplace WARNING! DO NOT operate fireplace before read- ing and understanding operating instructions. Failure to operate fireplace according to operating instructions could cause fire or injury...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 10 E. Fixed Glass Assembly See Section 14.H. D. Decorative Doors and Fronts WARNING! Risk of Fire! Install ONLY doors or fronts approved by Hearth & Home Technologies. Unapproved doors or fronts may cause fireplace to overheat. This appliance has b...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 11 H. Lighting Instructions (IPI) 1. This appliance is equipped with an ignition device which automatically lights the burner. DO NOT try to light the burner by hand. 2. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 12 Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • Turn the fireplace off and allow it to completely cool.• Remove fixed glass assembly. See Section 14.H.• Clean fixed glass assembly. See Section 3.•...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 13 Glass Cleaning Frequency: Seasonally By: Homeowner Tools Needed : Protective gloves, glass cleaner, drop cloth and a stable work surface. CAUTION! Handle fixed glass assembly with care. Glass is breakable. • Avoid striking, scratching or slamming gl...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 14 Venting Frequency: Seasonally By: Homeowner Tools needed: Protective gloves and safety glasses. • Inspect venting and termination cap for blockage or obstruction such plants, bird nests, leaves, snow, debris, etc. • Verify termination cap clearance ...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 15 A. Typical Appliance System NOTICE: Illustrations and photos reflect typical installations and are for design purposes only. Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual Figure 4.1 Typical System 4 G...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 16 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional outside air source...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 17 5 Framing and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1). WARNING! Risk of Fire or Burns! Provide adequate clearance around air...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 18 B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should be enclosed inside the chase. NOTICE: Treatment of ceiling firestops and wall ...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 19 NAILING TABS BOTH SIDES Figure 5.3 Nailing Tab Locations D. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as specified. Framing or finishing material closer than the minimums listed must be c...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 20 A. Vent Termination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 .................................................1.25* Over 7/12 to 8/12 ......................
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 21 O N P R Q X = AIR SUPPLY INLET A = 12 inches.................clearances above grade, veranda, porch, deck or balcony B = 9 inches...................clearance to window or door that may be opened, or to permanently closed window. C = 18 inches..........
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 22 A. Approved Pipe This appliance is approved for use with Hearth & Home Technologies DVP venting systems. Refer to Section 16B for vent component information. DO NOT mix pipe, fittings or joining methods from differ- ent manufacturers.The pipe is...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 23 F. Installation Instructions and Venting In- formation - PVI-DVP These instructions are for appliances utilizing the PVI-DVP. For appliances incorporating the PVK-80, see Section 7.J. IMPORTANT: Failure to read and follow these instruc- tions may cr...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 24 Installation of Vent Pipe For information on standard procedures for venting the appliance, refer to Section 10. For the allowable pipe lengths and elbow combinations for this appliance, consult Section 7.I. The PVI uses DVP pipe (8 inch) connection...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 25 If the PVI-DVP is being installed in a confined space (such as a utility closet, mechanical room or attic space) with a total volume less than 720 cubic ft, an 8 inch by 16 inch hole will be required directly in front of the access panel. The confin...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 26 CHASE APPLIANCE Note: AN 8 X 16 inch framed hole is required in front of the access panel. This hole may be covered with an open air louvered cover. Figure 7.9 Mount PVI-DVP to Chase Figure 7.10 PVI-DVP Mounted with Fresh Air Access 1/2 IN. MAX. FRO...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 28 FAN INTERMITTENT PILOT IGNITOR ORANGE WHITE SENSOR WIRE IGNITER WIRE 6VDC TRANSFORMER ELECTRICAL ACCESS KNOCKOUT APPLIANCE ON/OFF CONTROL HARNESS THERMO SNAP DISC HARNESS JUMPER HARNESS AUX300 MODULE WALL SWITCH JUMPER WIRE ACCESSORY CABLE IPI WIRE ...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 29 Figure 7.19 PVI Vertical Orientation - Switch and Wire ZIP TIE G. Operating Instructions After installation of the power vent, follow the operation instructions of the fireplace.1. Turn the ON/OFF/REMOTE switch on the black IPI module to the ON posi...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 30 Figure 7.22 Top Vent - Horizontal Termination Venting with 1 elbow H 1 V 1 Fire Risk. Explosion Risk.Do NOT pack insulation or other combustibles between ceiling firestops.• ALWAYS maintain specified clearances around venting and firestop systems.• ...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 31 H 1 INSTALLED HORIZONTALLY H 2 V 1 Figure 7.23 1. Top Vent - Horizontal Termination - (continued) Top Vent - Horizontal Termination Venting with 2 elbows Note : Use DVP Series components only. V 1 Minimum V 1 + H 1 + H 2 Maximum 2 ft. 610 mm 50 ft. ...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 33 Figure 7.25 Vertical Vent Maximum V 1 V 2 V 1 = 8 ft. Min. (2.4 m) Top Vent - Vertical Termination No Elbows V 2 = 50 ft. Max. (15.2 m)
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 34 Figure 7.26 H 1 V 2 V 1 Top Vent - Vertical Termination Venting with 2 elbows Note : Use DVP Series components only. V 1 Minimum V 1 + V 2 + H Maximum 2 ft. 610 mm 50 ft. 15.2 m 3 ft. 914 mm 60 ft. 18.3 m 4 ft. 1219 mm 70 ft. 21.3 m V 1 + V 2 + H 1 ...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 35 Figure 7.27 INSTALLED HORIZONTALLY H 1 H 2 V 2 V 1 Top Vent - Vertical Termination Venting with 3 elbows Note : Use DVP Series components only. V 1 Minimum V 1 + V 2 + H 1 + H 2 Maximum 2 ft. 610 mm 40 ft. 12.2 m 3 ft. 914 mm 50 ft. 15.2 m 4 ft. 121...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 36 NOTE : Maximum total vent run= Total vertical vent run + Total horizontal vent run V1 H1 H2 H3 V2 MAXIMUM VERTICAL DROP DIRECT VENT WITH 2 FT. MINIMUM VERTICAL OFF TOP OF APPLIANCE MAX. ELBOWS (45° & 90°) MAX. TOTAL VENT RUN Total V + Total H (F...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 37 NOTE : Maximum total vent run= Total vertical vent run + Total horizontal vent run V1 H1 H2 H3 V2 MAXIMUM VERTICAL DROP DIRECT VENT WITH 2 FT. MINIMUM VERTICAL OFF TOP OF APPLIANCE MAX. ELBOWS (45° & 90°) MAX. TOTAL VENT RUN Total V + Total H (F...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 39 NOTE: The PVK-80 Power Vent must terminate in a HORI- ZONTAL position. See Figure 7.31. 2. Install vent system components per planned vent run. Route the vent pipe from the fireplace to the Power Vent using the minimum number of elbows possible. 3. ...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 40 Note: The PVK-80 Power Vent includes a 6 1/2 foot 5-wire assembly wired into the vent cap blower motor. If this wire assembly will not reach the fireplace, the wires may need to be spliced to additional wire lengths in a junction box in- stalled ins...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 42 OPERATING INSTRUCTIONS After installation of the power vent, follow the operation instructions of the fireplace.1. Turn the fireplace ON/OFF switch to "ON". NOTE : During periods of operation after turning the fire- place "ON", there...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 43 METAL GUIDE PLATE MUST BE IN POSITION AS SHOWN Figure 7.42 H. Slide the blower assembly out of the 10-1/2 in. diameter collar for maintenance or replacement. FAN EXHAUST PORT EXHAUST HOLE Figure 7.43 METAL GUIDE PLATE Figure 7.44 2. TO REASSEMBLE TH...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 44 PVK-80 Top Vent - Horizontal Termination Venting with 1 elbow Fire Risk. Explosion Risk.Do NOT pack insulation or other combustibles between ceiling firestops.• ALWAYS maintain specified clearances around venting and firestop systems.• Install wall ...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 45 PVK-80 Top Vent - Horizontal Termination Venting with 2 elbows Note : Use DVP Series components only. V 1 Minimum V 1 + H 1 + H 2 Maximum 2 ft. 610 mm 20 ft. 6 m 3 ft. 914 mm 30 ft. 9.1 m 4 ft. 1.2 m 40 ft. 12.1 m V 1 + H 1 + H 2 = 40 ft. (12.1 m) M...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 46 H 1 H 2 V 2 V 1 PVK-80 Top Vent - Horizontal Termination Venting with 3 or more elbows Note : Use DVP Series components only. 3 Elbows V 1 + V 2 Minimum T otal V + T otal H Maximum 2 ft. 610 mm 20 ft. 6 m 3 ft. 914 mm 30 ft. 9.1 m 4 ft. 1.2 m 40 ft....
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 48 A. Pipe Clearances to Combustibles WARNING! Risk of Fire! Maintain air space clearance to vent. DO NOT pack insulation or other combustibles: • Between ceiling firestops • Between wall shield firestops • Around vent systemFailure to keep insulation ...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 49 C. Install the Ceiling Firestop A ceiling firestop MUST be used between floors and attics.• DVP pipe only - Frame an opening 10 in. by 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/floor (see Figure 8.3). • Frame the area with the...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 50 D. Install Attic Insulation Shield WARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home Technologies Inc. requires the use of an attic shield. The National Fuel Gas Code ANSI Z223.1 and NFPA 54 requires an ...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 51 CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. A. Top Vent 9 Appliance Preparation FIBERGLASS ROPE RING BOTTOM PANEL SCREW LOCATIONS 1. Remove seal cap...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 52 B. Securing and Leveling the Appliance WARNING! Risk of Fire! Prevent contact with: • Sagging or loose insulation • Insulation backing or plastic • Framing and other combustible materialsBlock openings into the chase to prevent entry of blown- in in...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 53 C. Active Convection Technology H2 V1 H1 H1 MAX. = 8 FT. H1 + V1 + H2 = 8 FT. MAX. = TWO 90° BENDS INLET CONVECTION AIR MAY BE VENTED IN ANY DIRECTION,INCLUDING DOWNWARD. LOUVERED GRILLE CLEARANCE FROM INTAKE TO OBJECTS = 24 IN. MIN. 24-IN. MIN. The...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 54 10 Installing Vent Pipe (DVP Pipe) Figure 10.2 High Temperature Silicone Sealant A. Assemble Vent Sections To attach the first vent component to the starting collars of the appliance:• Lock the vent components into place by sliding the pipe section ...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 55 C. Secure The Vent Sections • Vertical runs of pipe must be supported every 8 ft. (2.44 m).• Horizontal sections must be supported every 5 feet (1.52 m). • Vent supports or plumbers strap (spaced 120º apart) may be used to support. See figures 10.5 ...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 56 D. Disassemble Vent Sections • Rotate either section (see Figure 10.7) so the seams on both pipe sections are aligned as shown in Figure 10.8. • Pull carefully to separate the pieces of pipe. Figure 10.8 Align and Disassemble Vent Sections Figure 10...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 57 F. Install Metal Roof Flashing • See minimum vent heights for various pitched roofs (Figure 10.11) to determine the length of pipe to extend through the roof. • Slide the roof flashing over the pipe sections extending through the roof as shown in Fi...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 58 SCREWS CAULK STORM COLLAR (1 of 3) Figure 10.19 TERMINATION CAP H. Install Vertical Termination Cap • Attach the vertical termination cap by sliding the inner collar of the cap into the inner flue of the pipe section while placing the outer collar o...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 59 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home Technologies specified and approved parts. B. Gas Pressure • Optimum appliance ...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 60 C. Gas Connection • Refer to Reference Section 16 for location of gas line access in appliance. • Gas line may be run through either side of appliance.• The gap between supply piping and gas access hole may be caulked with caulk with a minimum of 30...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 61 A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code CSA C22.1. ...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 62 FAN INTERMITTENT PILOT IGNITOR ORANGE WHITE SENSOR WIRE IGNITER WIRE 6VDC TRANSFORMER ELECTRICAL ACCESS KNOCKOUT APPLIANCE ON/OFF CONTROL HARNESS THERMO SNAP DISC HARNESS JUMPER HARNESS AUX300 MODULE WALL SWITCH JUMPER WIRE IPI WIRE HARNESS MALE/FEM...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 63 D. Optional LED Lighting Circuit Figure 12.6 LED Wiring Diagram For models with LED lighting option only. POWER SUPPLY 6 LEAD WALL CONTROL WIRE APPLIANCE ON/OFF CONTROL HOT NEUTRAL PLUG IN PLUG IN LIGHT CONTROL ORANGE YELLOW GREEN RED BRN NOT USED F...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 64 Figure 12.7 Junction Box Detail 1. Remove the one screw that secures the junction box to the control tray panel. 2. Route the wire through the strain relief in the outer wrap and down through the knockout located on top side of the junction box. See...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 66 13 Finishing B. Framing and Finishing Instructions WARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as specified. Framing closer than the minimums listed must be constructed entirely of noncom- bustible materials (i.e., st...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 67 WARNING! Risk of Fire! Maintain specified air space clearances to combustibles.Inadequate air space may cause overheating and fire. Ensure that the one inch back clearance and one inch side clearances are maintained . WARNING! Risk of Fire! DO NOT u...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 68 C. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as specified. Framing closer than the minimums listed must be constructed entirely of noncom- bustible materials (i.e., steel studs, concrete ...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 69 Non-Combustible Finish Materials 0 to 1-1/4 inch thickness-Overlap Fit Method The mesh front is designed to overlap finish materials 0 inches to 1-1/4 inch thick. See Figure 13.7. NOTICE: This 1-1/4 inch maximum not only includes the decorative fini...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 70 Figure 13.9 Noncombustible Surface Finishing Material 0-4 Inches Thick-Inside Fit Method 1-11/16 IN. 1-11/16 IN. 20-1/2 IN. 1-3/8 IN. 1-3/8 IN. 65-1/2 IN. FIREPLACE VIEWING AREA = CLEARANCE FROM VIEWING AREA TO NON-COMBUSTIBLE FINISHING MATERIAL (IN...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 71 A. Remove Fixed Glass Assembly See Section 14.H. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the firebox. Verify all components are with the fireplace. C. Clean the Appliance Clean/vacuum any sawdust that may...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 72 Figure 6. Front Access Media Tray 7. Position the front tabs of the front access media tray toward the glass and then place in the groove of the glass frame. Line up the media tray so that the left and right cut-outs fit within the glass frame. 5. U...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 73 F. Porcelain Instructions A Porcelain Kit is available for use with the RED60 mod-els. Install Porcelain according to these instructions RED60 Model Without Media This kit contains the components necessary to install the porcelain on RED60 models th...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 75 Figure 15. Clips Located on Four Corners - Bottom Right Shown CLIP Figure 14. Porcelain Trim Base Installed. 9. Install four retainer clips (included) as shown in Figure 15. Outside corner trim piece will be forced into clip on front of fireplace. S...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 76 RED60 Model With Media This kit contains the components necessary to install the porcelain on RED60 models that have media installed. Kit Contents: (1) Inner back panel. See Figure 1.(2) Inner side panels. See Figure 2.(2) Outside corner trim pieces...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 78 Figure 12. Service Parts Diagram. Service Parts 1 2 3 2 1 ITEM DESCRIPTION PART NUMBER Refractory Kit POR60-L 1 Side Panel (Qty 2 req) 2159-219 2 Panel Side (Qty 2 req) 2159-223 3 Back Panel 2159-222 G. Granite Instructions A Granite Kit is availabl...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 79 Figure 4. Securing Tabs and Sheet Metal Screws. Figure 7. Outside Front Trim Base. Figure 5. Inner Front Base Pieces. 4-5/8 IN. Figure 6. Inner Rear Base Pieces. 19-3/8 IN. 3-3/4 IN. 19-3/8 IN. Figure 8. Middle and Outer Base Pan Granite Support Tab...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 80 Figure 12. Fastening Angle Tabs to Secure Granite in Place. Figure 11. Installing First Back Panel Granite Piece. 4. Secure granite pieces into place using the angle tabs and screws provided. See Figure 12. Begin with the back left piece and follow ...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 81 Figure 16. Installing Inner Front Granite Pieces. EQUAL GAP DEPTH ON BOTH SIDES OF GRANITE. 10. Install the glass frame assembly. 11. Position access panel so tabs are facing the glass as- sembly. Insert into glass frame. See Figure 17 and Figure 18...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 82 RED60 Model With Media This kit contains the components necessary to install the granite on single sided RED60 models that have media installed. Kit Contents: (3) Back panel pieces 19-13/16 inches wide x 16-7/8 inches tall. See Figure 1. (2) Inner s...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 83 Figure 7. Fastening Angle Tabs to Secure Granite in Place. 4. Slide side pieces into place from the front and hold in place while installing the angle tabs and screws pro- vided. Measure to be sure that the pieces are placed in the correct orientati...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 84 H. Sheet Metal Refractory Instructions A Sheet Metal Refractory Kit is available for use with the RED60 models. This kit contains the components neces- sary to install metal refractory on the RED60-NNN model. Install Sheet Metal Refractory Kit accor...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 85 Figure 7. Outside Front Trim Base Installed. TRIM BASE Figure 8. Clip Location. CLIP 6. Install outside corner trim pieces. Outside corner trim pieces will be forced into clip on front of fireplace. See Figure 8, Figure 9 and Figure 10. Figure 9. In...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 86 Figure 14.4 Air Shutter Figure 14.3 Fixed Glass Assembly I. Fixed Glass Assembly WARNING! Risk of Asphyxiation! Handle fixed glass assembly with care. Inspect the gasket to ensure it is undamaged and inspect the glass for cracks, chips or scratches....
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 87 15 Troubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualified service technician in the diagn...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 88 A. IntelliFire Plus™ Ignition System (continued) 4. (Continued) Pilot lights but contin- ues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot flame has been lit, flame rectification has not occurred.) C. Mo...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 89 16 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5. Figure 16.1 Appliance Dimensions RED60 Location Inches Millimeters L ...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 90 Figure 16.2 DVP vent components B. Vent Components Diagrams 10-1/2 in. (267 mm) 10-7/8 in. (276 mm) 45 ° 7-3/8 in. (187 mm) 11-3/8 in. (289 mm) 1-1/4 in. (32 mm) 9-1/4 in. (235 mm) 13-1/4 in. (337 mm) 1/2 in. TYP DVP90ST (90° Elbow) 10 in. (254 mm) ...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 91 DVP-HPC1 DVP-HPC2 DVP-TRAP1 DVP-TRAP2 DVP-HPCK1-B DVP-HPCK2-B DVP-TRAPK2 DVP-TRAPK1 DVP-TRAP Horizontal Termination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a minimum of 1-1/2 in....
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 92 B. Vent Components Diagrams (continued) Figure 16.5 DVP Series Vent Components 13-1/4 in. (337 mm) 24-5/8 in. (625 mm) 27-1/2 in. (699 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in. (625 mm) 13-1/4 in. (337 mm) RF12M Roof Flashing Multi...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 93 B. Vent Components Diagrams (continued) 7-1/4 in. 12 in. 305 mm (184 mm) 5-1/4 in. (133 mm) 12-1/2 in. (318 mm) DVP-TVHW VerticalTermination Cap (Highwind) PVK-80 (For use with IPI and DSI appliances only.) 1 in. (25 mm) 14 in. (356 mm) 3/8 in. (10 ...
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 98 Heat & Glo, a brand of Hearth & Home Technologies Inc. 7571 215th St, Lakeville, MN 55044 www.heatnglo.com D. Contact Information Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat...
Heat & Glo Manuals
-
Heat & Glo SL-550TV-IPI-E
Manual
-
Heat & Glo CF750ENH
Manual
-
Heat & Glo ST-HV-IPI
Manual
-
Heat & Glo 6000GLX-IPILP-S/-R
Manual
-
Heat & Glo st-42tvfl
Manual
-
Heat & Glo 7000XLS
Manual
-
Heat & Glo 8000TV-OAK-IPI
Manual
-
Heat & Glo EM-415 - 36
Manual
-
Heat & Glo 350TRSILP-AUF
Manual
-
Heat & Glo Exclaim-50
Manual
-
Heat & Glo 6000 Series
Manual
-
Heat & Glo XLR-PLUS-N-AU
Manual
-
Heat & Glo 8000CFLP-OAKIPI
Manual
-
Heat & Glo BE-41C
Manual
-
Heat & Glo VRT-GY-P-AUB
Manual
-
Heat & Glo 6000CL-IPI-S
Manual
-
Heat & Glo ST-36TRLP-IPI
Manual
-
Heat & Glo SL-550TV-D
Manual
-
Heat & Glo 6000GL-IPILP-S
Manual
-
Heat & Glo BW36
Manual