Page 2 - Listing Label Information/Location; This owner ’s manual; Homeowner Reference Information; Model Number; XXXXXXXX; Read this manual before installing or operating this appliance.
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on fi replace: ___________...
Page 3 - Safety Alert Key:; • NOTICE: Used to address practices not related to personal injury.; Table of Contents; User Guide
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. •...
Page 6 - This warranty is void if:; QRWOLPLWHGWRLPSURSHUFKLPQH\RUYHQWLQJLQVWDOODWLRQ; LIMITATIONS OF LIABILITY:; DWLRQRIJODVV
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 6 B. Limited Lifetime Warranty (continued) 4021-645C 12-29-10 Page 2 of 2 WARRANTY CONDITIONS: 7KLVZDUUDQW\RQO\FRYHUV++7DSSOLDQFHVWKDWDUHSXUFKDVHGWKURXJKDQ++7DXWKRUL]HGGHDOHURUGLVWULEXWRU$OLVWRI ++7DXWKRUL]HGGHDOHUVLVDYDLODEOHRQW...
Page 7 - NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.; Listing and Code Approvals; TYPE: Direct Vent Gas Appliance Heater; Models
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 7 B. Tempered Glass Specifi cations Hearth & Home Technologies appliances manufactured with tempered glass may be installed in hazardous loca-tions such as bathtub enclosures as defi ned by the Con-sumer Product Safety Commissi...
Page 8 - T h e f o l l o w i n g r e q u i r e m e n t s r e f e r e n c e va r i o u s
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 8 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including thos...
Page 9 - Operating Instructions; A. Gas Fireplace Safety; WARNING; HOT SURFACES; touch glass until it is cooled
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 9 2 2 Operating Instructions Figure 2.1 General Operating Parts B. Your Fireplace WARNING! DO NOT operate fi replace before read-ing and understanding operating instructions. Failure to operate fi replace according to operating ins...
Page 10 - have a
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 10 D. Clear Space WARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.3. Avoid placing candles and other heat-sensitive objects on mantel or heart...
Page 11 - NOT FOR USE; Final inspection by
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 11 I. Lighting Instructions (IPI) The IPI system may be operated with two D-cell batteries. To prolong battery life, remove them when using the transformer. 1. This appliance is equipped with an ignition device which automatically ...
Page 12 - ISSUE; Condensation on the glass
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 12 Initial Break-in Procedure • T h e f i r e p l a c e s h o u l d b e r u n t h r e e t o f o u r h o u r s continuously on high. • Turn the fi replace off and allow it to completely cool. • Remove fi xed glass assembly. See Sect...
Page 13 - Glass Cleaning; Tools Needed; Maintenance and Service; Tools needed; Remote Control
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 13 Glass Cleaning Frequency: Seasonally By: Homeowner Tools Needed : Protective gloves, glass cleaner, drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care. Glass is breakable. • Avoid striking, scr...
Page 15 - Burner Ignition and Operation; DO NOT
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 15 Figure 3.4 IPI Pilot Flame Patterns Burner Ignition and Operation Frequency: Annually By: Qualifi ed Service Technician Tools needed: Protective gloves, vacuum cleaner, whisk broom, fl ashlight, voltmeter, indexed drill bit set,...
Page 16 - A. Typical Appliance System; Getting Started; Installer Guide; Dual venting c onf igurations; ARE NOT; b e ve nt e d; E I T H E R; ve r t i c a l l y; O R
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 16 A. Typical Appliance System NOTICE: Illustrations and photos refl ect typical installations and are for design purposes only. Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual Figure ...
Page 17 - Read all of the instructions before starting the instal-; C. Tools and Supplies Needed; • Installation and use of any damaged appliance or vent; Any such action may cause a fi re hazard.
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 17 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No addition...
Page 18 - Framing and Clearances; A. Selecting Appliance Location
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 18 5 5 Framing and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1). WARNING! Risk of Fire or Burns! Provide adequa...
Page 19 - B. Constructing the Appliance Chase; • Insulation and other materials must be secured to prevent; Inches
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 19 C A B D B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should be enclosed inside the chase. NOTICE: Treatment o...
Page 21 - See-Through Combustible Mantel; D. Mantel and Wall Projections; PIER Non-Combustible Mantel
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 21 Note: All measurements in inches. MEASUREMENTS FROM TOP EDGE OF THE OPENING 5 10 11 12 2-1/ 2 13 14 15 16 17 18 19 32 TO CEILING 9 10 11 12 8 7 6 5 4 3 25 18 See-Through Combustible Mantel PIER Combustible Mantel Note: All measu...
Page 23 - A. Vent Termination Minimum Clearances; Termination Locations; pack air space with insulation or other
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 23 A. Vent Termination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0*Over 6/12 to 7/12 .................................................1.25*Over 7/12 to 8/12 ...
Page 24 - public; Covered Alcove Applications; NOT
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 24 Figure 6.3 Minimum Clearances for Termination O N P R Q X = AIR SUPPLY INLET A = 12 inches.................clearances above grade, veranda, porch, deck or balcony B = 12 inches.................clearance to window or door that ma...
Page 25 - B. Continue Adding Vent Components; To Install the Heat Shield:; CORRECT; C. Install Support Brackets; elbow in the venting system.
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 25 B. Continue Adding Vent Components To Install the Heat Shield: 1. Determine if the heat shield is required. Do so by measuring the vertical distance between the top horizontal surface of the elbow to any combustible surface abov...
Page 26 - mix pipe, fi ttings or joining methods from differ-; Vent Information and Diagrams; D. Measuring Standards; • Pipe measurements are shown using the effective length; Horizontal
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 26 A. Approved Pipe This appliance is approved for use with Hearth & Home Technologies a DVP venting system. Refer to Section 16B for vent component information. DO NOT mix pipe, fi ttings or joining methods from differ- ent ma...
Page 27 - Note: The Multi-Sided series fi replaces can adapt; After; Reference Figure 7.14 for
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 27 To replace the fi rst starter elbow with two 45° elbows, refer to Figure 7.3. All other 90° elbows can be replaced with two 45° elbows. General Rules: • A maximum of three 90° elbows (or six 45° elbows) may be used in any vent c...
Page 28 - Elbow only; Elbow only
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 28 H 1 V 1 Figure 7.4 Figure 7.5 One Elbow Two Elbows INSTALLED HORIZONTALLY H 1 H 2 V 1 1. Top Vent - Horizontal Termination - (continued) V 1 Minimum H 1 Maximum Elbow only 1-1/2 ft. 457 mm 6 in. 152 mm 2-1/2 ft. 610 mm 1 ft. 305...
Page 29 - Three Elbows
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 29 Figure 7.6 1. Top Vent - Horizontal Termination - (continued) Three Elbows V 1 Minimum H 1 Maximum V 2 Minimum H 2 Maximum V 1 + V 2 Minimum H 1 + H 2 Maximum Elbow only 1 ft. 305 mm 6 in. 152 mm 1 ft. 305 mm 6 in. 152 mm 1 ft. ...
Page 30 - No Elbow; If installing a vertical vent/; Exhaust restrictor Instructions; Remove refractory panel and exhaust baffl e from pilot
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 30 Refractory Panel To access the exhaust opening, remove the refractory panel and exhaust baffle. To remove refractory panel, remove the two screws on top. To remove the exhaust baffle, remove the three screws securing it. Top Ven...
Page 31 - Restrictor; Note; BREAK
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 31 Figure 7.10 4. Center the exhaust restrictor in the open end of the ex- haust outlet and secure through the slots on the exhaust restrictor with the 2-1/4 in. self tapping screws provided in the appliance manual bag. 5. Reinstal...
Page 32 - One Elbow; Two Elbows; ELBOW ONLY
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 32 V 1 H 1 Maximum V 2 V 1 + V 2 Minimum One Elbow 2-1/2 ft. 762 mm * * * 2 ft. 607 mm 6 ft. 1.8 m * * * 4 ft. 1.2 m 12 ft. 3.7 m * * * 6 ft. 1.8 m 18 ft. 5.5 m V 1 + V 2 + H 1 = 50 ft (15.2 m) Maximum *No specifi c restrictions on...
Page 33 - use a 45o elbow
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 33 3. Rear Vent - Horizontal Termination Figure 7.13 Figure 7.14 No Elbow One 45° Elbow H 1 = 16 in. (406 mm) Maximum H 1 H 1 DO NOT use a 45º elbow in corner installations. Use two 90º elbow instead.
Page 35 - Back to Back 90° Elbows
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 35 4. Rear Vent - Vertical Termination One Elbow Figure 7.17 Two Elbows Figure 7.18 V 1 H 1 INSTALLED HORIZONTALLY H 2 V 2 H 1 V 1 Minimum H 1 Maximum 1 ft. 305 mm 3 ft. 914 mm 2 ft. 610 mm 5 ft. 1.5 m 3 ft. 914 mm 7 ft. 2.1 m 4 ft...
Page 36 - *No specifi c restrictions on this value EXCEPT; Maximum
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 36 4. Rear Vent - Vertical Termination - (continued) Three Elbows Figure 7.19 Three Elbows Figure 7.20 INSTALLED HORIZONTALLY H 3 H 2 V 1 H 1 V 2 V 1 H 2 H 1 H 1 H 2 H 3 V 1 Minimum H 1 + H 2 + H 3 Maximum * * * 8 ft. 2.4 m 4 ft. 1...
Page 37 - A. Pipe Clearances to Combustibles; Vent Clearances and Framing; When venting off the top of the unit and terminating; B. Wall Penetration Framing; Combustible Wall Penetration; • The opening must be framed on all four sides using the; Non-Combustible Wall Penetration
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 37 A. Pipe Clearances to Combustibles WARNING! Risk of Fire! Maintain air space clearance to vent. DO NOT pack insulation or other combustibles: • Between ceiling fi restops• Between wall shield fi restops• Around vent system Failu...
Page 38 - C. Vertical Penetration Framing; ATTIC ABOVE; A ceiling fi restop; MUST; be used between; DVP pipe only; • Frame the area with the same sized lumber
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 38 C. Vertical Penetration Framing Figure 8.3 Figure 8.4 Installing the Attic Shield 3 FASTENERS PER SIDE INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP INSTALLED BELOW CEILING CEILING...
Page 39 - D. Install Attic Insulation Shield; Flat Ceiling Installation; Vaulted Ceiling Installation
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 39 D. Install Attic Insulation Shield WARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home Technologies Inc. requires the use of an attic shield. The National Fuel Gas Code ANSI Z223.1 and...
Page 40 - Appliance Preparation; Cut the metal retaining band and fold the sides
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 40 CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal-lation. Sheet metal edges are sharp. NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a ...
Page 42 - C. Securing and Leveling the Appliance; Once appliance is setup for top or rear venting, it; Failure to ensure that the fireplace opening
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 42 C. Securing and Leveling the Appliance WARNING! Risk of Fire! Prevent contact with: • Sagging or loose insulation• Insulation backing or plastic• Framing and other combustible materials Block openings into the chase to prevent e...
Page 43 - Attach Vent to the Firebox Assembly; The end of the pipe sections with the lanced tabs will face; Make sure that the seams are not aligned to prevent; INCORRECT; Lances
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 43 10 10 Installing Vent Pipe (DVP and SLP Pipe) A. Assemble Vent Sections (DVP Pipe Only) Attach Vent to the Firebox Assembly Note: The end of the pipe sections with the lanced tabs will face toward the appliance. Attach the fi rs...
Page 44 - C. Assemble Slip Sections; Pilot hole; • Apply a bead of silicone sealant inside the female outer
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 44 B. Assemble Vent Sections (SLP Pipe Only) To attach the fi rst vent component to the starting collars of the appliance: • Attach a DVP-2SL adapter to the starting collar of the appliance. • Lock the vent components into place by...
Page 45 - E. Disassemble Vent Sections
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 45 120º Figure 10.8 Securing Vertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections E. Disassemble Vent Sections • Rotate either section (see Figure 10.10) so the seams on both pipe sections are aligned as shown ...
Page 46 - F. Install Decorative Ceiling Components
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 46 F. Install Decorative Ceiling Components (SLP only) A decorative ceiling thimble can be installed on a fl at ceil-ing through which the vent passes. The decorative ceiling thimble is used to cover the fi restop. • Seal the gap b...
Page 47 - G. Install Metal Roof Flashing; CAULK; H. Assemble and Install Storm Collar
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 47 G. Install Metal Roof Flashing • See minimum vent heights for various pitched roofs (Figure 10.14) to determine the length of pipe to extend through the roof. • Slide the roof fl ashing over the pipe sections extending through t...
Page 48 - I. Install Vertical Termination Cap; Heat shields may not be fi eld constructed.; K. Heat Shield Requirements for Horizontal; • DO NOT remove the heat shields attached to the
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 48 SCREWS CAULK STORM COLLAR (1 of 3) Figure 10.18 Figure 10.18 TERMINATION CAP I. Install Vertical Termination Cap • Attach the vertical termination cap by sliding the inner collar of the cap into the inner fl ue of the pipe secti...
Page 49 - L. Install Horizontal Termination Cap (DVP
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 49 Cap Specifi cation Chart (depth without using additional pipe sections) 36 inch Multisided Series DVP-TRAPK1 Top Vent Depth DVP-TRAP1 Rear Vent Depth DVP-TRAPK2 Top Vent Depth DVP-TRAP2 Rear Vent Depth 2-7/8 in to 4-3/4 in 3-1/8...
Page 50 - • Purge should be performed by; Gas Information; Gas Pressure; • If substituting for these components, please consult; D. High Altitude Installations
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 50 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home Technologies specifi ed and approved parts. B. Gas Pressur...
Page 51 - Electrical Information; D. Junction Box Installation; INSIDE
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 51 A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Elec...
Page 52 - AN ELECTRIC CODE; The electrical junction box provided with the fi replace
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 52 E. WSK-MLT Multifunction Wall Switch The WSK-MLT multifunctional wall switch is designed to control fl ame height, blower speed and auxilary func-tions on your gas fi replace. For models equipped with the Intellifi re system (IP...
Page 53 - Wiring the Wall Switch
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 53 Wiring the Wall Switch • Install the provided control wire from the fi replace to the switch location. (Control wire for Heatilator products is supplied with the fi replace). NOTICE: Do not to stress the wire around tight or sha...
Page 54 - F. Install the Flame Solenoid; Do not; G. Connect the Temperature Sensor Switch
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 54 GAS CONTROL VALVE VARIABLE REGULATOR FLAME CONTROL SOLENOID WASHER VARIABLE REGULATOR VARIABLE REGULATOR WASHER PLUNGER JAM NUT NUT SCREW KNOB SOLENOID Figure 12.4 Install the Flame Solenoid F. Install the Flame Solenoid • Remov...
Page 55 - I. Setting Flame Height/Manifold Pressure; J. Wall Switch Button Operation; Flame Button; The temperature displayed by the wall switch may take
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 55 I. Setting Flame Height/Manifold Pressure (To be done by a qualifi ed service technician.) Upon initial power-up of this device, valve pressure must be set for fl ame adjustment. • Loosen output pressure tap on valve and connect...
Page 56 - Can be operated independently of all functions.; The controller will turn off the fi replace at 2° F over
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 56 Cold Climate Button • Button Press: Turns on Climate Control • Button Press: Turns off Climate Control This allows the pilot fl ame to stay lit when activated. A benefi t of this is reduced condensation on the glass at start-up ...
Page 57 - Finishing; Risk of Fire; To install the Splatter Guard:
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 57 13 13 Finishing A. Splatter Guard The splatter guard is a piece of corrugated material used to protect the appliance during the installation process be-fore fi nishing work on the whole hearth is complete. Splatter guards must b...
Page 59 - B. Mantel and Wall Projections
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 59 Note: All measurements in inches. MEASUREMENTS FROM TOP EDGE OF THE OPENING 5 10 11 12 2-1/ 2 13 14 15 16 17 18 19 32 TO CEILING 9 10 11 12 8 7 6 5 4 3 25 18 Note: All measurements in inches. MEASUREMENTS FROM TOP EDGE OF THE OP...
Page 60 - Top and Side Seal Joint
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 60 Figure 13.16 Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening) TOP VIEW 2-3/4 in. Min. 1/2 in. Min. Unlimited 1 in.Max. FIREPLACE OPENING Note: Clearance from opening to perpendicular wall. C. Faci...
Page 61 - D. Finishing Material; Stop fi nishing material fl ush with opening.; Finishing materials over 1 inch thick.; Finishing materials 1 inch maximum thick.
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 61 Figure 13.19 Overlap Fit Door Figure 13.18 Folio Door and Aero Figure 13.20 Inside Fit Door DOOR FIT FINISH MATERIAL MAXIMUM THICKNESS SEE FIGURE Aero Inside Any 13.18 Folio Inside Any 13.18 Arcadia Overlap 1 inch 13.19 Inside A...
Page 63 - E. Elevated Hearth Systems
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 63 E. Elevated Hearth Systems Use the table below to identify the hearth system that will be used. The table will also help identify effects on the various dimensions. Some hearth systems will elevate the appliance off the fl oor a...
Page 64 - Appliance Setup; Placement; Prepare Electric Ember Bed and Lava Rock.
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 64 A. Remove Fixed Glass Assembly See Section 14G. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox. C. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside ...
Page 65 - Placing the Ember Material; • Embers CANNOT be placed directly over ports. Care
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 65 WARNING! Risk of Explosion! Follow ember placement instructions in manual. DO NOT place embers directly over burner ports. Replace ember material annually. Improperly placed embers interfere with proper burner operation. Placing...
Page 66 - F. Install the Log Assembly; Logs are fragile! Carefully remove the logs; BAR
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 66 F. Install the Log Assembly 2005-937F 9/08 Log Set Assembly: LOGS-MSR Models: PIER-HV, ST-HV, LCOR-HV, RCOR-HV ST-36TR, PIER-36TR, TWILIGHT-II-B CAUTION: Logs are fragile! Carefully remove the logs from the packaging. Remove the...
Page 68 - Notch; Log Assembly Installed.; Notch engaged with
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 68 STEP 7. LOG #6 (SRV2005-705): Locate the notch on log #6 and place it against the front right grate tine. Set the other end of the log so it rests on the fl at area of log #1. The orientation of log #6 in relation to the grate t...
Page 69 - I. Air Shutter Setting; G. Fixed Glass Assembly; Air Shutter Settings; H. Install Trim Kits and Surrounds; Removing Fixed Glass Assembly; NG
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 69 I. Air Shutter Setting This appliance has an adjustable air shutter (which con-trols the primary air) factory set for the minimum vertical vent run. If your installation has more than the minimum required vertical vent length, a...
Page 70 - Troubleshooting; A. IntelliFire Ignition System; Symptom
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 70 15 15 Troubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualifi ed techni...
Page 71 - a. A shorted or loose connection in fl ame
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 71 IntelliFire Ignition System - (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot fl ame has been lit, ...
Page 72 - Reference Materials; A. Appliance Dimension Diagram; Location Inches
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 72 16 16 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5. Figure 16.1 See-Through Dimensions B C FRONT ...
Page 74 - B. Vent Components Diagrams
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 74 B. Vent Components Diagrams Figure 16.3 DVP vent components 10-1/2 in.(267 mm) 10-7/8 in. (276 mm) 45 ° 7-3/8 in. (187 mm) 11-3/8 in.(289 mm) 1-1/4 in. (32 mm) 9-1/4 in. (235 mm) 13-1/4 in.(337 mm) 1/2 in. TYP DVP90ST (90° Elbow...
Page 75 - Horizontal Termination Cap; Max; The heat shield is designed to be; Heat
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 75 DVP-HPC1 DVP-HPC2 DVP-TRAP1 DVP-TRAP2 DVP-TRAPK2 DVP-TRAPK1 DVP-TRAP Horizontal Termination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (3...
Page 78 - Optional Wire Harness; Power Vent Inline
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 78 B. Vent Components Diagrams (continued) Figure 16.7 Vent Components 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) DVP-HRC-SS Optional Wire Harness DESCRIPTION PART NUMBER 10 ft. PV Wire Harness PVI-WH10 20 ft. PV Wire Harne...
Page 79 - Effective Height/Length; Horizontal Pipe
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 79 B. Vent Components Diagrams (continued) Figure 16.8 SLP Series Vent Components EFFECTIVE HEIGHT/ LENGTH 8-3/4 in.222 mm 6-1/2 in.165 mm 6-5/8 in.168 mm 6 in. 152 mm 6-1/2 in.165 mm 6-5/8 in.168 mm 9-7/8 in.251 mm 6-1/2 in.165 mm...
Page 81 - ITEM; Log Set Assembly; 6” See-Through Gas Fireplace
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 81 C. Service Parts ST-36TR-IPI Beginning Manufacturing Date: Nov. 2008 Ending Manufacturing Date:______ IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model num...
Page 82 - 6” Pier Direct Vent Fireplace
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 82 C. Service Parts PIER-36TR-IPI Beginning Manufacturing Date: Nov. 2008 Ending Manufacturing Date: ______ IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model ...
Page 83 - Additional service part numbers appear on following page.
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 83 PIER-36TR, ST-36TR-IPI C. Service Parts Beginning Manufacturing Date: Nov. 2008 Ending Manufacturing Date: ______ IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provi...
Page 85 - D. Contact Information; For the location of your nearest Heat & Glo dealer,; DO NOT DISCARD THIS MANUAL; NOTICE; • Leave this manual with
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 85 Heat & Glo, a brand of Hearth & Home Technologies Inc. 7571 215 th Street West, Lakeville, MN 55044 www.heatnglo.com D. Contact Information Please contact your Heat & Glo dealer with any questions or concerns. For th...