Page 2 - Congratulations; Owner’s Manual; Read this manual before installing or operating this appliance.; Homeowner Reference Information; NA; XXXXXXXX
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 2 Congratulations Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on appliance: ______________...
Page 3 - Table of Contents; A. Maintenance Tasks
3 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 Table of Contents 1 Listing and Code Approvals A. Appliance Certifi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4B. Glass Specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 4 - Model; This installation must conform with local codes. In the; Listing and Code Approvals; TYPE: Vented Gas Fireplace Heater; Material which will not ignite and burn. Such materials are; NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 4 Manufactured Home or Mobile Home installation may occur only after the home is site located and must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a s...
Page 6 - A. Design and Installation Considerations; Getting Started; B. Tools and Supplies Needed; CAUTION; Any such action may cause a fi re hazard.; C. Inspect Appliance and Components; Read all of the instructions before starting the instal-
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 6 A. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outs...
Page 7 - Framing and Clearances; A. Selecting Appliance Location
7 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 Model A B C D E F G H I J K Paloma Inches 6 10-1/8 12-1/8 54 36 30-3/4 13-1/4 13-1/4 1 15-1/2 5 Millimeters 152 257 308 1372 914 781 337 337 25 394 127 3 3 Framing and Clearances Note:• Illustrations reflect typi...
Page 8 - It is permissible to place the appliance on carpet.; B. Clearances to Combustibles
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 8 Note: Flooring beneath appliance may reach 90 degrees plus room ambient temperature. Check with flooring manufacturer for maximum temperature allowed on flooring surfaces. It is permissible to place the appliance...
Page 9 - A. Vent Termination Minimum Clearances; • Do not pack air space with insulation or other; Termination Locations; Measure horizontal clearances from this surface.; WARNING
9 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 A. Vent Termination Minimum Clearances Fire Risk. Explosion Risk. Maintain vent clearance to combustibles as specifi ed. • Do not pack air space with insulation or other materials. Failure to keep insulation or o...
Page 10 - = AREA WHERE TERMINAL IS NOT PERMITTED; Alcove Applications; public
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 10 V = VENT TERMINAL X = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 4.4 Minimum Clearances for Termination A = 12 inches.................clearances above grade, veranda, porch, deck or balcony B...
Page 11 - ALL vent confi guration specifi cations MUST be followed.; Vent Information; A. Venting Components; Horizontal
11 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 Fire Hazard. Explosion Risk. Asphyxiation Risk. Do NOT connect this gas appliance to a chimney fl ue serving a separate solid-fuel or gas burning appliance. • Vent this appliance directly outside. • Use separate...
Page 12 - D. How to Use the Vent Graph; Example 1; E. Venting Guidelines
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 12 EX. 2 EX. 1 2' 4' 6' 8' 10' 12' 14' 15' 30' 28' 26' 24' 22' 20' 18' 16' 14' 12' 10' 8' 6' 4' 2' 0' (MAX) (MIN) 32' 34' 35' 11-5/8” 2 ft. (610 mm) Maximum Horizontal run with novertical pipe and with 1/4 in. (6 m...
Page 13 - F. Horizontal Termination
13 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 Figure 5.3 Figure 5.4 Adding Venting Components 4. For installations using a round support box/wall thimble (check pipe manufacturer's instructions), mark the wall for a 10 in. x 10 in. (254 mm x 254 mm) square ...
Page 14 - The four wood screws provided should be replaced
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 14 8 in. (203 mm) 7 in. (178 mm) 7 in. (178 mm) 6 in. (152 mm) 5. Installation requires a minimum of 6 in. (152 mm) horizontal run of vent with a 1/4 in. (6 mm) rise run towards the termination. Each 1 ft. (305 mm)...
Page 15 - Place the wall thimble cover over the pipe assembly; The attachment from the vent pipe to the vent
15 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 11. Place the wall thimble cover over the pipe assembly and slide the appliance and vent assembly towards the wall, carefully inserting the vent pipe into the vent termination cap assembly. It is important that ...
Page 16 - et the gas appliance in its desired location. Drop; G. Vertical Termination
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 16 40 ft. (12 m) MAXIMUM Figure 5.10 VERTICAL TERMINATION CAP STORM COLLAR FLASHING FIRESTOP PIPE LENGTH SUPPORT BOX Figure 5.11 1. Check the installation instructions for required 1 in. (25 mm) clearances (air spa...
Page 18 - H. Secure the Vent Sections
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 18 CEILING FIRESTOP NAILS MINIMUM 1 in. (25 mm) CLEARANCE MINIMUM 1 in.(25 mm) CLEARANCE MINIMUM 1 in.(25 mm) CLEARANCE MINIMUM 1 in.(25 mm) CLEARANCE Figure 5.16 9. Twist-lock the vent cap and seal. Note: For mult...
Page 19 - Assemble the desired lengths of pipe and elbows; I. Disassemble Vent Sections; • Pull carefully to separate the pieces of pipe.
19 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 J. Cathedral Ceiling 1. Follow installation Steps 1 and 2 under vertical instal- lation section, page 16. 2. Remove shingles or other roof covering as necessary to cut the rectangular hole for the support box. C...
Page 20 - K. Class A Metal Chimney; Measure the distance from the top of the chimney to; • Have inspection done by qualifi ed chimney sweep or; Place the support clamp (provided with the support
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 20 K. Class A Metal Chimney Figure 5.20 1. Remove existing chimney cap. 2. Measure the distance from the top of the chimney to the bottom of the ceiling support box, add 3 in. (76 mm) to this measurement, and cut a...
Page 21 - L. Existing Masonry Chimney; Type A
21 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 Figure 5.22 Figure 5.23 4. Pass the flex pipe down through the center of the chimney system, and center the top adapter on the top of the chimney pipe. Drill four 1/8 in. (3 mm) diameter holes through the top ad...
Page 22 - CUT AND BEND FLASHING
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 22 7. If additional lengths of flex liner are needed to span the chimney height, use a flex coupler to connect the pieces of flex liner together. Connect the flex to the coupler by using four sheet metal screws for...
Page 23 - Attach the flex to the retro connector. Use three sheet; Slide wall thimble cover over retro connector and
23 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 HIGH WIND TERMINATION CAP #SLK-991DA TOP ADAPTOR THREE SHEET METAL SCREWS FLASHING 9. Attach the flex to the retro connector. Use three sheet metal screws to attach the flex liner to the connector (Figure 5.29)....
Page 24 - Lay the trim ring on fl at surface and bend up; M. Slim Line Wall Thimble
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 24 3/4 3/4 3/4 Assembling Slim Line Trim Ring and Heat Shield Installing Slim Line Trim Ring and Heat Shield Measure from the fl oor to the center of the vent pipe. Cut out a 9-1/2 in. (241 mm) hole in the wall. Ho...
Page 25 - FIG. A 90 DEGREE ELBOW; FIG. C MINIMUM CLEARANCE; FIG. B 45 DEGREE ELBOW
25 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 FIG. A 90 DEGREE ELBOW FIG. C MINIMUM CLEARANCE HTI VENT HHW2 PART #841-0670 (RECOMMENDED FOR OPTIMUM PERFORMANCE) TRIM RING WALL THIMBLE CENTER LINE MINIMUM OF 6 IN. (152 MM) OF PIPE THROUGH THE WALL INTERIOR W...
Page 26 - Gas Information; Pressure; If the pressure is not suffi cient, ensure:
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 26 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home Technologies specifi ed and approved part...
Page 27 - HIGH ALTITUDE INSTALLATIONS
27 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 Leak test all gas line joints and the gas control valve prior to and after starting the appliance. Before making the gas connection, ensure that the appliance you are installing is designed for the type of gas b...
Page 28 - Ignition System Wiring; Wire Size; A. Recommendation for Wire; Electrical Information; National Electric Code ANSI/NFPA 70-latest; B. Connecting to the Appliance
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 28 C. IntelliFire ® Ignition System Wiring This appliance requires a 110 VAC supply to the appliance junction box for operation. A wiring diagram is shown in Figure 7.2 on the next page. This appliance is equipped ...
Page 29 - BATTERY LOCATION; D. Loss of Power and Battery Backup Usage; Remove the front door assembly and lower access; • Replace damaged wire with type 105o C rated; • Do not install batteries if the backup mode may not be used
29 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 Figure 7.2 NOTE: Appliance will not operateunless properly grounded. * TRANSFORMER 3 VAC PLUG IN VALVE GROUND TO APPLIANCE CHASSIS PIGGYBACK ON/OFF SWITCH INTERMITTENT PILOT IGNITOR IGNITION MODULE 3 VAC I S WHT...
Page 30 - • The power supply for the appliance must be brought into; Red
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 30 Figure 7.4 Junction Box Wired to Wall Switch E. Wall Switch Installation for Fan (Optional) If the box is being wired to a wall mounted switch for use with a fan (See Figure 7.4): • The power supply for the appl...
Page 31 - B. Unbolting Appliance from the Pallet; Appliance Setup; A. Remove Shipping Materials
31 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 B. Unbolting Appliance from the Pallet The appliance is bolted and screwed to the pallet for ship-ping. Use a 1/2 in. socket to remove the bolt in center of bottom plate. Use a Phillips screwdriver to remove the...
Page 32 - C. Leveling and Lagging Down the Appliance; Lagging the appliance down is; REQUIRED; Securing holes
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 32 Figure 8.5 LAGGING CLEARANCE HOLE Using pliers, adjust the counterscrews to level the appli-ance. Place the lag bolt from the component bag in the center hole in the bottom plate (lagging clearance hole). The ap...
Page 33 - E. Top to Rear Vent Conversion
33 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 Figure 8.10 Figure 8.9 Figure 8.8 E. Top to Rear Vent Conversion Kit Contents: Top cover (no hole); Back panel (with hole). Tools Required: Power drill; #2 Phillips bit; 5/32 in. (4 mm) Allen wrench; 5/8 in. (16...
Page 34 - Air Shutter Settings; NG; Install the cover plate and gasket removed from the
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 34 G. Installing the Vent Restrictor The vent restrictor plate must be installed before installing the baffle. On the top of inside firebox for top vent ,on back of firebox for rear vent, loosen the three screws ou...
Page 35 - H. Installing Rock Media and Ember Material; Place the rear rock cluster in the fi rebox as shown in; RIGHT ROCK; Delayed Ignition Risk
35 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 H. Installing Rock Media and Ember Material CAUTION! Risk of Cuts or Abrasions. Wear protective gloves and safety glasses during installation. KIT CONTENTS (1) Rear Rock Cluster (1) Left Rock Cluster (1) Right R...
Page 36 - Place left rock cluster in fi rebox as shown in Figure 5.
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 36 4. Ember material is shipped with this kit. To place the ember material: WARNING! Risk of Explosion! Follow ember placement instructions. DO NOT place embers directly over burner ports. Replace ember material an...
Page 37 - Blower; Installation precautions
37 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 Figure 8.21 I. Optional Blower The GFK-160A Blower has been designed to circulate room air through the appliance to enhance heat output. The GFK-160A blower system operates on 120 VAC, 60 Hz power. This is avail...
Page 38 - The switch/bracket assembly must be installed so; Push excess wires neatly towards the rear of the appliance.
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 38 Figure 8.24 Locate the machine screw underneath the firebox on the right side. Position the temperature sensor switch/bracket assembly over the machine screw and attach with the wing nut. Finger tighten. See Fig...
Page 39 - Recommended operating procedures
39 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 Recommended operating procedures Ignite the fire in the appliance with the variable speed control switch in an "ON" position. The fan will automati-cally turn on when the temperature sensor switch closes...
Page 40 - tighten or damage may occur.; Remote receiver; Reinstall the blower into the blower bracket.
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 40 Installing flame control solenoid Remove the screw and knob from the variable regulator and discard. Unscrew the nut from the regulator and discard. Remove the bag containing a washer and blue and red plungers f...
Page 41 - Wiring the flame control solenoid:
41 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 RED JUMPER WIRE TO BROWN WH IT E ORANGE INTERMITTENT PILOT IGNITOR IGNITION MODULE 3 VAC REMOTE RECEIVER ORANGE GREEN BLACK RED VALVE GROUND TO FIREPLACE CHASSIS TRANSFORMER 3 VAC PLUG IN ORANGE ORANGE RED RED F...
Page 42 - L. Inner Glass Door Assembly Replacement; Replace with a new inner glass door assembly.; K. Front Door Glass Assembly Replacement; CAP AND BARREL FASTENER SYSTEM; DO NOT
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 42 L. Inner Glass Door Assembly Replacement Turn the appliance OFF and let it cool down before replac-ing the inner glass door assembly. With the front door assembly removed from the appliance, remove the inner gla...
Page 43 - A. Before Lighting Appliance; Operating Instructions; HOT SURFACES
43 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 B. Controls On/off Switch: When this switch is in the ON position, the pilot ignitor is engaged until temperature is established. The burner automatically turns on. Valve Variable Control: This knob controls the...
Page 44 - NOT FOR USE; Final inspection by
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 44 C. Lighting Instructions (IPI) The IPI system may be operated with two D-cell batteries. When using batteries, unplug the transformer. To prolong battery life, remove them when using the transformer. 1. This app...
Page 45 - Initial Break-in Procedure; The appliance should be run three to four hours; D. After Appliance is Lit; ISSUE
45 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 Initial Break-in Procedure When you light the appliance, you may notice that it pro-duces heat which does have an associated odor or smell. If you feel this odor is excessive it may require the initial three to ...
Page 46 - Troubleshooting; A. IntelliFire Ignition System; Symptom
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 46 10 10 Troubleshooting A. IntelliFire Ignition System With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troub...
Page 47 - A. A shorted or loose connection in fl ame
47 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 IntelliFire Ignition System - (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot fl a...
Page 48 - When cleaning glass door:
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 48 11 11 Maintaining and Servicing Appliance Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a qualifi ed service technician should perform an applianc...
Page 50 - Hearth Pad; Reference Materials; A. Appliance Dimension Diagram
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 50 Height includes 3/8 in (9.53 mm) hearth pad B C I G D H F E A Hearth Pad Height includes 3/8 in (9.53 mm) hearth pad Figure 12.1 Appliance Dimensions Location Inches Millimeter Location Inches Millimeter A 18-7/...
Page 51 - B. Vent Components Diagram
51 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 B. Vent Components Diagram Figure 12.3 SLP Series Vent Components 9-7/16 in. 240 mm 6-9/16 in. 167 mm 6-9/16 in. 167 mm 6-9/16 in. 167 mm 6-9/16 in. 167 mm 6 in. 152 mm 6-1/2 in.165 mm 9-3/4 in.248 mm 9-1/4 in.2...
Page 52 - MISCELLANEOUS
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 52 C. Vent Components List COMPONENTS SLP-WT-BK Ceiling Support / Wall Thimble, Black SLP-CCS-BK Cathedral Ceiling Support, Black SLP6-BK 6 inch Pipe Length, Black SLP4-BK 9 inch Pipe Length, Black SLP12-BK 12 inch...
Page 53 - Service Parts Diagram; Part number list on following page.; Rock Placement
53 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 Beginning Manufacturing Date: Aug 2009Ending Manufacturing Date: ______ D. Service Parts Service Parts Diagram PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA GY-MOD Paloma-GY-MOD ( Gray), Paloma-GR-MOD ( Green), Paloma-BZ...
Page 54 - ITEM
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 54 D. Service Parts List PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA GY-MOD IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial numb...
Page 55 - #22 Bottom Plate Assembly
55 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 Beginning Manufacturing Date: Aug 2009Ending Manufacturing Date: ______ D. Service Parts PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA GY-MOD IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement p...
Page 57 - E. Limited Lifetime Warranty; LIMITED LIFETIME WARRANTY
57 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 E. Limited Lifetime Warranty 4021-645C 12-29-10 Page 1 of 2 Hearth & Home Technologies Inc. LIMITED LIFETIME WARRANTY Hearth & Home Technologies Inc., on behalf of its hearth brands (”HHT”), extends the ...
Page 58 - This warranty is void if:; QRWOLPLWHGWRLPSURSHUFKLPQH\RUYHQWLQJLQVWDOODWLRQ; LIMITATIONS OF LIABILITY:; DWLRQRIJODVV
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 58 4021-645C 12-29-10 Page 2 of 2 WARRANTY CONDITIONS: 7KLVZDUUDQW\RQO\FRYHUV++7DSSOLDQFHVWKDWDUHSXUFKDVHGWKURXJKDQ++7DXWKRUL]HGGHDOHURUGLVWULEXWRU$OLVWRI ++7DXWKRUL]HGGHDOHUVLVDYDLODEOHRQWKH++7EUDQGHGZHEVLWHV ...
Page 59 - F. Contact Information; For the location of your nearest Heat & Glo dealer,; DO NOT DISCARD THIS MANUAL; • Leave this manual with
59 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12 Heat & Glo, a brand of Hearth & Home Technologies Inc. 7571 215th Street West, Lakeville, MN 55044 www.heatnglo.com F. Contact Information Please contact your Heat & Glo dealer with any questions or ...