Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 2 Read this manual before installing or operating this fi replace. Please retain this owner’s manual for future reference. Congratulations on selecting a Heat & Glo LifeStyles Collection wood burning fi replace. The Heat &am...
Page 3 - Table of Contents
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 3 Table of Contents 1 Listing and Code Approvals 4 A. Appliance Certi fi cation . . . . . . . . . . . . . . . . . . . . . . . . . 4 2 Getting Started 5 A. Design and Installation Considerations . . . . . . . . . . . . 5B. Typica...
Page 4 - Listing and Code Approvals; cation; WARNING
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 4 1 1 Listing and Code Approvals A. Appliance Certi fi cation This fi replace system has been tested and listed in accor- dance with UL 127 standard by Underwriters Laboratories Inc. for installation and operation in the United ...
Page 5 - Getting Started; A. Design and Installation Considerations; CAUTION; When installed on exterior walls:; fl
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 5 2 2 Getting Started A. Design and Installation Considerations Draft is the pressure difference needed to vent fi replaces successfully. Considerations for successful draft include: • Location of fi replace and chimney Check bu...
Page 6 - B. Typical Fireplace System
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 6 B. Typical Fireplace System The Heat & Glo fi replace system consists of the following: • Fireplace/integral grate/dual cooling air system• Refractory• Chimney termination cap• Chimney system • Hearth extension Figure 2.2 ...
Page 7 - D. Inspect Fireplace and Components; • Read all the instructions before starting the installation.; C. Tools and Supplies Needed
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 7 Before beginning the installation be sure the following tools and building supplies are available: Reciprocating saw Framing material Pliers High temp caulking material Hammer GlovesPhillips screwdriver Framing square Flat bla...
Page 8 - Framing and Clearances; A. Selecting Fireplace Location; Fire Risk; • When Installed on Surfaces Where Water May Collect
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 8 3 3 Framing and Clearances A. Selecting Fireplace Location This outdoor fi replace will shed moderate amounts of water, but is not waterproof. Water and condensing water vapor may enter the chase under certain conditions. The ...
Page 9 - Model; FREESTANDING
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 9 B A H F Note: If this surface is inside the building’s warm air envelope... ...then this surface must be an exterior wall system. CD G G C D H G F J I E Figure 3.1 Fireplace Locations Model A B C D E F G H I J MONTANA-36 in. 2...
Page 10 - • Comply with all minimum clearances to
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 10 0 in. 0 in. to level of standoffs Combustible Object 36 in. (914 mm) 1-1/2 in. (38 mm) Drywall 0 in. 1/2 in. (13 mm) 1-1/2 in. (38 mm) B. Clearances Figure 3.3 Clearances to Combustible Materials Fire Risk • Comply with all m...
Page 11 - D. Frame the Fireplace; Figure 3.5 shows a typical framing (using 2 x 4 lumber) of the; BRICK; Cat
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 11 Note: Fireplace header cannot be positioned until the fireplace assembly is in place. 2 in. minimum air space clearance to the enclosure. 42-3/8 in. A 42-3/8 in. header height.Use only noncombustiblematerial below the top oft...
Page 12 - E. Chimney Requirements; Minimum overall straight height is 6 ft 4 in. if the; ft
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 12 E. Chimney Requirements When planning your fi replace location, the chimney construc- tion and necessary clearances must be considered. The fi re- place system and chimney components have been tested to provide fl exibility i...
Page 13 - A. Install the Dual Cooling Air Kit; Sharp Edges
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 13 72 in. min. TR11 Termination Cap A. Install the Dual Cooling Air Kit The cooling air kit is supplied as a standard feature with this fi replace and is required for safe operation. Installation must be done at the time of init...
Page 14 - B. Secure the Fireplace; • Position the Fireplace; • Level the Fireplace; • Place the Protective Metal Hearth Strips
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 14 B. Secure the Fireplace • Position the Fireplace This fi replace may be placed on either a combustible or noncombustible continuous fl at surface. Follow the in- structions for framing in Section 3.D. Slide the fi replace int...
Page 15 - A. Chimney Requirements
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 15 A. Chimney Requirements Vertical distances are measured from the base of the fi re- place as shown in Figure 5.2. To determine the chimney components needed to complete your particular installation, follow the steps below: • ...
Page 17 - C. Assemble the Chimney Sections; D. Install the Ceiling Firestops
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 17 C. Assemble the Chimney Sections Attach either a straight chimney section or an offset to the top of the fi replace (depending on your installation require- ment). Chimney sections are locked together by pushing downward unti...
Page 19 - A. Chimney Termination; and
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 19 Figure 6.1 Ceiling/Attic Construction Fire Risk • Must maintain 2 in. air (51 mm) clearance to insulation and other combustible materials. WARNING 6 6 Complete the Enclosure A. Chimney Termination Chimney Termination Requirem...
Page 20 - C. Install the Termination Cap
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 20 Termination Cap Storm Collar Slope Downward Turn-down Drip Edge Chase(Chimney) 2 in. (51 mm) Collaron Chase Top Caulk .018 (26 ga) min.GalvanizedChase Top Figure 6.2 Chase Top Construction 2 in. (51 mm) min. collar 6 in. (152...
Page 21 - For installations utilizing an ST1175 Square Termination
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 21 2 in. (51 mm) min. 4-1/2 in. (114 mm) max. 1-1/2 in. (38 mm) min. overlap Cap Standoff Top of Pipe Flashing Collar Figure 6.5 Installing an ST1175 Square Termination Cap The last section of pipemust stop between thedistances ...
Page 22 - Accessories
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 22 A. Gas Log/Lighter Provisions A certi fi ed gas log lighter or decorative gas log set can be installed in this fi replace. This fi replace was not teste3d and listed for use with an un- vented gas log heater. Do not install a...
Page 23 - Finishing
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 23 8 8 Finishing A. Hearth Extension A hearth extension must be installed with all fi replaces to protect the combustible fl oor in front of the fi replace from both radiant heat and sparks. See Figures 8.1 -8.3. 2 in. (51 mm)re...
Page 24 - B. Finishing Material
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 24 B. Finishing Material • Combustible Material Material which is made of or surfaced with wood, compressed paper, plant fi bers, plastics, or any material capable of igniting and burning, whether fl ame proofed or not, plastere...
Page 25 - A. General Information; Damper
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 25 HOT! DO NOT TOUCH. SEVERE BURNS MAY RESULT.CLOTHING IGNITION MAY RESULT. • Keep children away. • CAREFULLY SUPERVISE children in same room as fi replace. • A l e r t c h i l d r e n a n d a d u l t s t o h a z a r d s o f h i...
Page 26 - C. Clear Space Near the Fireplace
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 26 D. Flue Damper The fl ue damper must be in full open position, and is oper- ated by moving the handle up toward the top of the fi replace. Before lighting the fi re, verify this by looking up from the in- side of the fi repla...
Page 27 - Seasoning
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 27 G. Grate The factory installed integral grate must be used to hold the logs from falling out of an open fi replace and to allow air to pass between the burning logs. It is important to keep the fi re off the hearth and to all...
Page 29 - Diagnostics and Problem Solving; Troubleshooting; I can’t get a good; I don’t get enough/any heat from the
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 29 Diagnostics and Problem Solving 10 10 Troubleshooting I can’t get a good fi re going. What am I doing wrong? Diagnostic Questions Possible Causes of Condition Solutions Is the damper open? • No draft Open damper. Is there eno...
Page 30 - C. Firebox Refractory
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 30 A. Disposal of Ashes Ashes should be placed in a metal container with a tight- fi t- ting lid. The closed container of ashes should be placed on a noncombustible fl oor or on the ground, well away from all combustible materia...
Page 31 - D. Maintenance Task List; When cleaning glass door:; Inspect
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 31 Fire Risk • Do not use chimney cleaners or fl ame colorants in your fi replace. Will corrode chimney. WARNING D. Maintenance Task List Asphyxiation RiskFire Risk Annual inspection by qualified technician recommended. Check: •...
Page 32 - Reference Materials; A. Fireplace Dimensions
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 32 12 12 Reference Materials A. Fireplace Dimensions C 23 in. [597 mm] D B 42-3/8 in. [1076 mm] 38-3/4 in. [984 mm] A 23-1/2 in. [597 mm] 6-3/4 in. [171 mm] B 41-3/4 in. [1060 mm] (effective height) 9-1/2 in. [241 mm] E Gas Log ...
Page 33 - B. Fireplace Components; Description
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 33 B. Fireplace Components Bi-fold Glass Doors Traditional Brick Pattern Refractory Herringbone Pattern Refractory 20 in. (508 mm) 66 in. (1676 mm) 1/2 in. (13 mm) HX4 Hearth Extension 16 in. (406 mm) 52 in. (1321 mm) 1/2 in. (1...
Page 34 - C. Chimney Components; ID4 Insulated Duct
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 34 C. Chimney Components The following pictures show only those chimney components which may be safely used with this fi replace. 13 in. (330 mm) 14 in. (356 mm) 14 in. (356 mm) 5-1/4 in. (133 mm) 4 in. (102 mm) CAK5A Chimney Ai...
Page 37 - Woodburning Termination Cap; Shroud
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 37 Woodburning Termination Cap Shroud TS345/T445 (Top Vent) TR342/TR344TR442/TR444 TV342 TR342/TR344*TR442/TR444* (* with TR-TVK installed) TR11/TR11T TV11/TV11T TR11/TR11T* (* with TR-TVK installed) OPEN TOP with solid sides an...
Page 38 - Service Parts; MONTANA SERIES; Ending Manufacturing Date: Active
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 38 D. Service Parts Exploded Parts Diagram Outdoor Woodburning Fireplace Service Parts MONTANA SERIES Beginning Manufacturing Date: 9/8/03 Ending Manufacturing Date: Active 1 2 3 6 5 4
Page 39 - Description of Part
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 39 Service Parts ListOutdoor Woodburning Fireplace Service Parts MONTANA SERIES Beginning Manufacturing Date: 9/8/03 Ending Manufacturing Date: Active # Description of Part MONTANA-36 MONTANA-42 Qty. req. 1 Starter Collar 30399 ...
Page 40 - This page intentionally left blank.
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 40 This page intentionally left blank.
Page 44 - – NOTES –; F. Contact Information; DO NOT DISCARD THIS MANUAL; • I m p o r t a n t; DO
Heat & Glo LifeStyles Collection • Montana • 4039-150 Rev I • 08/06 44 Please contact your Heat & Glo dealer with any questions or concerns. For the number of your nearest Heat & Glo dealer, please call 1-888-427-3973. – NOTES – F. Contact Information DO NOT DISCARD THIS MANUAL CAUTION •...