Page 2 - Congratulations; Listing Label Information/Location; Owner’s Manual; Read this manual before installing or operating this appliance.; Homeowner Reference Information; NATURA L GAS
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 2 Congratulations Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on appliance: ____...
Page 3 - Table of Contents
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 3 Table of Contents 1 Listing and Code Approvals A. Appliance Certifi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4B. BTU Specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4C. High Altitude In...
Page 4 - Note; Listing and Code Approvals; C. High Altitude Installations; Models; A. Appliance Certifi cation; Material which will not ignite and burn. Such materials are; E. Combustible Materials Specifi cation; WARNING; NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 4 Note : To assure top performance, safety and effi ciency, inserts must be installed with an approved fl ue liner as per CAN/CGA B-149 or National Fuel Gas Code ANSI Z223 and these instructions. Note: This installation must conform with l...
Page 5 - Getting Started; C. Inspect Appliance and Components; • Read all of the instructions before starting the insta-; CAUTION; Any such action may cause a fi re hazard.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 5 Heat & Glo gas inserts are designed for recessed installa-tions into solid fuel masonry or factory built non-combustible fi replaces that have been installed in accordance with the National, Provincial, State and local building codes...
Page 6 - Fireplace Size Requirements; A. Minimum Fireplace Opening; • Any smoke shelves, shields, baffl es and the metal fl oor; NOTE: For actual appliance dimensions refer to Section 15.; TOP VIEW; Front Width
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 6 3 3 Fireplace Size Requirements A. Minimum Fireplace Opening Minimum fi replace opening requirements are shown in Figure 3.1. • The fi rebrick (refractory), glass doors, screen rails, screen mesh and log grates can be removed from a fact...
Page 8 - A. Vent Termination Minimum Clearances; Termination Locations
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 8 Fire Risk. Asphyxiation Risk. • Terminations MUST meet minimum clearances. • Exhaust gases are hot. • Nearby vents may draw fumes into house. A. Vent Termination Minimum Clearances Figure 4.1 specifi es minimum vent heights for various p...
Page 9 - C. Measuring Standards; • Vertical terminations are measured to top of chimney.; B. Horizontal Venting; Horizontal venting is NOT allowed.; Vent Information and Diagrams; Symbol
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 9 CAUTION ALL vent specifi cations MUST be followed. • This product is tested and listed to these specifi cations. • Appliance performance will suffer if specifi cations are not followed. Figure 5.1 C. Measuring Standards Vertical measurem...
Page 10 - Installation Preparation; D. Hearth or Hearth Extension; Prior to installing the gas insert:
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 10 6 6 Installation Preparation Fire Risk. A hearth or hearth extension (if present) must comply with either of the following: • The solid fuel burning fi replace manufacturer’s specifi cation. • Local building codes required by authority ...
Page 11 - A. Venting Components; Installing Vent Pipe and Appliance; B. Connecting Vent Pipe; Reference instructions in the termination kit.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 11 A. Venting Components 7 7 Installing Vent Pipe and Appliance The vertical vent termination system installed on this model includes: • One 3-foot section stainless steel fl exible pipe (included with insert). • One length of 3-inch fl ex...
Page 12 - • Trim chimney top plate to minimize excess overhang or
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 12 Figure 7.2 CUT AND BEND FLASHING AS NEEDED TO FIT CHIMNEY SEALANT ADHESIVE • Trim chimney top plate to minimize excess overhang or bend over fl ue tile (see Figure 7.2). • Place 3/8 inch bead of 300º F silicone on fl ue tile top. C. Pla...
Page 13 - D. Installing Adaptor and Termination Cap; Damper Flashing Kit; : Damper may have to be removed to use this kit.; system REQUIRES this insulation.; Masonry; OR
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 13 D. Installing Adaptor and Termination Cap For installation of termination cap see minimum vent heights for various pitched roofs (see Figure 7.2) . To install adaptor see Figure 7.3. Roof Pitch H (Min.) Ft.Flat to 6/12.....................
Page 14 - Gas Information; • If substituting for these components, please consult; Refer to; Reference Section 16; for location of gas line; Pressure
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 14 • Ensure that gas line does not come in contact with outer wrap of appliance. Follow local codes. • Incoming gas line should be piped into the valve compartment and connected to the 1/2 inch connection on the manual shutoff valve. • Che...
Page 15 - HIGH ALTITUDE INSTALLATIONS; • A small amount of air will be in the gas supply lines.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 15 Fire hazard. Do NOT change the valve settings. • This valve has been preset at the factory. • Changing valve settings may result in fi re hazard or bodily injury. HIGH ALTITUDE INSTALLATIONS U.L. Listed gas appliances are tested and app...
Page 16 - A. Wiring the Appliance; Electrical Information; • An ON/OFF switch is included with the decorative; Appliance Requirements; • This appliance DOES NOT require 110-120 VAC to
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 16 A. Wiring the Appliance 9 9 Electrical Information Note : This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition o...
Page 17 - B. Junction Box Installation; Optional Accessories; • Detach fl exible liner from back of unit if insert is installed.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 17 B. Junction Box Installation Figure 9.2 Junction box installation JUNCTION BOX SIDEWALL FEED PLUG THROUGH HOLE INSERT STRAIN RELIEF AROUND CORD IN THIS END FROM OUTSIDE OF UNIT SCREW PROVIDED Optional Accessories Connecting the electric...
Page 19 - A. Mantel Projections; Finishing; B. Installing Trim Surrounds; Combustible materials; MUST NEVER; overlap onto the
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 19 A. Mantel Projections Figure 10.1 shows the minimum vertical and corresponding maximum horizontal dimensions of appliance mantels or other combustible projections above the top front edge of the appliance, not the surround. See Figure 1...
Page 20 - Appliance Setup; A. Remove Shipping Materials; Placing the Ember Material; • Embers CANNOT be placed directly over ports.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 20 Figure 11.1 Placement of Embers EMBER MATERIAL (TOP SURFACE, AND FRONT) BURNER PAN AIR SHUTTER 11 11 Appliance Setup A. Remove Shipping Materials Remove shipping materials from inside or underneath the fi rebox. B. Clean the Appliance C...
Page 21 - E. Positioning the Logs; This model uses locating tabs to positively; Log Set; Logs are fragile! Carefully remove the logs from the packaging.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 21 Log Set Assembly: LOGS-CFXGB E. Positioning the Logs This model uses locating tabs to positively locate the logs with respect to the grate assembly. Please refer to grate assembly. LOG NUMBER 1 (SRV768-701): Place log #1 onto the grate....
Page 22 - log. Push down until log is sitting fl at on grate.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 22 LOG NUMBER 3 (SRV768-705): Position log #3 onto grate such that tab E fi ts into slot on bottom surface of log. Push down until log is sitting fl at on grate. LOG NUMBER 4 (SRV582-705): Place log #4 across both fl at spots on log #1 and...
Page 23 - Carefully remove the logs from the packaging.; GRATE ASSEMBLY; Push log back until it rests against locating tabs A and B.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 23 LOG PLACEMENT INSTRUCTIONS Carefully remove the logs from the packaging. CAUTION: Logs are fragile! 773-936B 10/07 GRATE ASSEMBLY This model uses locating tabs to positively locate the logs with respect to the grate assembly. Please ref...
Page 24 - and the right back side of log is fl ush against tab E.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 24 LOG #2 (SRV773-702): Position Log #2 onto grate such that tab C fi ts into the slot on bottom surface of log. LOG #3 (SRV768-704): Position log #3 onto grate such that the tab D fi ts into the slots on bottom surface of log and the righ...
Page 25 - Assembly; Removing Glass Assembly; • To release glass assembly, pull latch forward and allow; Replacing Glass Assembly; G. Air Shutter Setting; NG; Full open
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 25 Figure 11.16 Glass Assembly F. Glass Assembly Removing Glass Assembly There are two glass latches on the bottom of glass assembly. • To release glass assembly, pull latch forward and allow to retract away from glass assembly. • Remove g...
Page 26 - A. Before Lighting Appliance; This appliance has a Standing Pilot Ignition.; Operating Instructions; HOT SURFACES
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 26 Fire Risk. Explosion Risk. Gas may build up while lighting pilot. • Remove glass assembly before lighting pilot. • Replace glass assembly after lighting pilot. A. Before Lighting Appliance This appliance has a Standing Pilot Ignition. B...
Page 27 - B. Lighting Appliance; Standing Pilot Ignition; NOT FOR USE; WHAT TO DO IF YOU SMELL GAS
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 27 B. Lighting Appliance Standing Pilot Ignition 1. Turn off all electric power to the appliance if service is to be performed. 2. Open control access panel. 3. Move switch to “OFF” position. 4. Push in gas control knob slightly and turn c...
Page 28 - C. Check Pilot Flame Appearance; • Pilot; D. After Appliance is Lit; Initial Break-in Procedure; : The appliance should be run three to four hours
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 28 C. Check Pilot Flame Appearance Pilot fl ame must contact the thermocouple and thermopile for reliable appliance operation. • Pilot fl ame should be as shown in Figure 12.1. D. After Appliance is Lit Initial Break-in Procedure When you ...
Page 29 - E. Frequently Asked Questions; ISSUE
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 29 E. Frequently Asked Questions Fire Risk. High Temperatures. Keep combustible household items away from appliance. Do NOT obstruct combustion and ventilation air. • Do NOT place combustible items on top of or in front of appliance. • Kee...
Page 30 - A. Standing Pilot Ignition System; Troubleshooting; Symptom
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 30 A. Standing Pilot Ignition System 13 13 Troubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will ...
Page 32 - Maintaining and Servicing Appliance; When cleaning glass door:
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 32 14 14 Maintaining and Servicing Appliance Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a qualifi ed service technician should perform an appliance checkup at the beginnin...
Page 34 - Reference Materials; A. Appliance Dimension Diagram
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 34 Figure 15.1 Appliance Dimensions D F E H G ELECTRICAL ACCESS (IF EQUIPPED) GAS INLET C A B 2-1/16 in. 52 mm 1-9/16 in. 40 mm 3-9/16 in. 91 mm 1-1/16 in. 28 mm 2-1/2 in. 64 mm 4 in. 102 mm 13-3/4 in. 350 mm 3-1/8 in. 80 mm 6-5/8 in.169 m...
Page 35 - B. Vent Kits Components; Direct Vent Flex Liner Accessory Kits
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 35 B. Vent Kits Components Direct Vent Flex Liner Kits (see Figure 15.2) LINK-DV-30B or (LINK-DV-30): Masonry 3 inch fl ex liner kit. Expands to 30 feet. Includes: two liners, termination cap, fl ashing, and link adapter. LINK-DV4-30B or (...
Page 36 - Service Parts Diagram; Part number list on following page.; Log Set Assembly
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 36 C. Service Parts Service Parts Diagram FB-GRAND-S Beginning Manufacturing Date: Oct. 2007 Ending Manufacturing Date: ______ Part number list on following page. Log Set Assembly 1 2 3 4 5 6 7 10 11 8 9
Page 37 - Service Parts List; Stocked; ITEM
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 37 Service Parts List FB-GRAND-S IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an au...
Page 38 - Service Parts
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 38 Service Parts Service Parts Diagram FB-IN-S Beginning Manufacturing Date: Oct. 2007 Ending Manufacturing Date: ______ Part number list on following page. Log Set Assembly 1 2 3 4 5 6 7 10 11 8 9
Page 41 - D. Limited Lifetime Warranty; unless expressly authorized and approved by HEAT & GLO in writing.
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 41 © 2007 Hearth & Home Technologies Inc. LIMITED LIFETIME WARRANTY HEAT & GLO GAS APPLIANCE PRODUCTS 060-981E 10/07 D. Limited Lifetime Warranty BASIC ONE-YEAR WARRANTY. HEAT & GLO, a brand of HEARTH & HOME TECHNOLOGIES IN...
Page 42 - E. Contact Information; For the location of your nearest Heat & Glo dealer,; DO NOT DISCARD THIS MANUAL
Heat & Glo • FB-IN-S, FB-GRAND-S • 783-910 Rev. D • 3/08 42 Heat & Glo, a brand of Hearth & Home Technologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 www.heatnglo.com E. Contact Information Please contact your Heat & Glo dealer with any questions or concerns. For the loc...