Page 2 - Read this manual before installing or operating this appliance.; NA; XXXXXXXX
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on fi replace: __________...
Page 3 - Safety Alert Key:; • NOTICE: Used to address practices not related to personal injury.; Table of Contents; B. Tempered Glass Speci; User Guide
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. ...
Page 5 - B. Limited Lifetime Warranty
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 5 B. Limited Lifetime Warranty Î
Page 7 - fl; NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.; Listing and Code Approvals; TYPE: Direct Vent Gas Appliance Heater; Models
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 7 B. Tempered Glass Specifi cations Hearth & Home Technologies appliances manufactured with tempered glass may be installed in hazardous loca-tions such as bathtub enclosures as de fi ned by the Con- sumer Product Safety Commi...
Page 8 - T he fo ll ow in g r e quir em ent s r efer e nc e var i o us
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 8 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including tho...
Page 9 - A. Gas Fireplace Safety; WARNING; HOT SURFACES; touch glass until it is cooled; Operating Instructions
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 9 Figure 2.1 General Operating Parts B. Your Fireplace WARNING! DO NOT operate fi replace before read-ing and understanding operating instructions. Failure to operate fi replace according to operating instructions could cause fi r...
Page 10 - Assembly; H. Before Lighting Fireplace; have a
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 10 D. Clear Space WARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hear...
Page 11 - NOT FOR USE; Final inspection by
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 11 I. Lighting Instructions (IPI) The IPI system may be operated with two D-cell batteries. When using batteries, unplug the transformer. To prolong battery life, remove them when using the transformer. 1. Turn off all electric po...
Page 13 - ISSUE
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 13 Initial Break-in Procedure• T h e f i r e p l a c e s h o u l d b e r u n t h r e e t o f o u r h o u r s continuously on high. • Turn the fi replace off and allow it to completely cool. • Remove fi xed glass assembly. See Sect...
Page 14 - Glass Cleaning; Tools Needed; Note; Maintenance and Service; Tools needed; Remote Control; Installation and repair should be done by a quali
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 14 Glass Cleaning Frequency: Seasonally By: Homeowner Tools Needed : Protective gloves, glass cleaner, drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care. Glass is breakable. • Avoid striking, sc...
Page 15 - DO NOT
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 15 Venting Frequency: Seasonally By: Homeowner Tools needed: Protective gloves and safety glasses. • Inspect venting and termination cap for blockage or obstruction such plants, bird nests, leaves, snow, debris, etc. • Verify term...
Page 17 - A. Typical Appliance System; D ual vent ing c onf igurat ions; ARE NOT; b e v e n t e d; E I T H E R; v e r t i c a l l y; O R; Getting Started; Installer Guide
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 17 A. Typical Appliance System NOTICE: Illustrations and photos refl ect typical installations and are for design purposes only. Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual Figure...
Page 18 - Read all of the instructions before starting the instal-; C. Tools and Supplies Needed; Any such action may cause a fi re hazard.
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 18 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additio...
Page 19 - Framing and Clearances; A. Selecting Appliance Location; Inches
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 19 5 5 Framing and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1). WARNING! Risk of Fire or Burns! Provide adequ...
Page 20 - B. Constructing the Appliance Chase; MINIMUM FRAMING DIMENSIONS
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 20 B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should be enclosed inside the chase. NOTICE: Treatment of ceili...
Page 21 - D. Mantel and Wall Projections; Combustible Mantels; Measurement is taken from top of the
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 21 D. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clear-ances as specifi ed. Framing or fi nishing material closer than the minimums listed must be constructed entirely of noncom-bustible materials (...
Page 22 - A. Vent Termination Minimum Clearances; Termination Locations; pack air space with insulation or other; Gas, Wood or Fuel Oil
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 22 A. Vent Termination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0*Over 6/12 to 7/12 .................................................1.25*Over 7/12 to 8/12...
Page 23 - = AREA WHERE TERMINAL IS NOT PERMITTED; Covered Alcove Applications; public
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 23 O N P R Q V = VENT TERMINAL X = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 6.3 Minimum Clearances for Termination A = 12 inches.................clearances above grade, veranda, porch, deck or balcony B = 12 ...
Page 24 - ttings or joining methods from differ-; Vent Information and Diagrams; D. Measuring Standards; • Horizontal terminations are measured to the outside; Horizontal
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 24 A. Approved Pipe This appliance is approved for use with Hearth & Home Technologies DVP or SLP venting systems. Refer to Sec-tion 16B for vent component information. DO NOT mix pipe, fi ttings or joining methods from differ...
Page 25 - Top Vent - Horizontal Termination
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 25 INSTALLED HORIZONTALLY H 1 H 2 V 1 H 1 V 1 Figure 7.3 Figure 7.4 Top Vent - Horizontal Termination Top Vent - Horizontal Termination One Elbow Two Elbows Note: For corner installations: A 6 inch (152 mm) section of straight pip...
Page 26 - Three Elbows; Elbow only
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 26 Figure 7.5 Top Vent - Horizontal Termination - (continued) Three Elbows H 2 H 1 V 2 V 1 V 1 Min. H 1 Max. V 2 Min. H 2 Max. Elbow only 2 ft. 610 mm 0 in. 0 mm 1 ft. 305 mm 6 in. 152 mm 3 ft 914 mm 6 in. 152 mm 2 ft. 610 mm 1 ft...
Page 27 - Top Vent - Vertical Termination; If installing a vertical vent/; Flue Restrictor Instructions; Remove exhaust shield using a 1/4 inch nut driver by; BREAK
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 27 EXHAUST SHIELD FLUE RESTRICTOR Top Vent - Vertical Termination No Elbow Figure 7.6 Note: If installing a vertical vent/ termination off the top of the ap-pliance, the fl ue restrictor should be used. V 1 V 1 = 40 ft. Max. (12.4...
Page 28 - Two Elbows; Maximum
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 28 H 1 V 1 V 2 Top Vent - Vertical Termination (continued) Figure 7.11 Two Elbows Figure 7.10 4. Center the Flue Restrictor on vent and secure in place by using two self-tapping screws (see Figure 7.10). 5. Reinstall the Exhaust S...
Page 29 - Minimum H
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 29 Figure 7.12 Top Vent - Vertical Termination - (continued) Three Elbows INSTALLED HORIZONTALLY H 1 H 2 V 1 V 2 V 1 H 1 + H 2 V 2 V 1 + V 2 Minimum H 1 + H 2 Maximum Elbow only 1 ft. 305 mm * * * 1 ft. 305 mm 6 in. 152 mm 2 ft. 6...
Page 31 - Back to Back
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 31 INSTALLED HORIZONTALLY H 3 H 1 H 2 V 1 Rear Vent - Horizontal Termination - (continued) Two Elbows Figure 7.15 Figure 7.16 Three Elbows H 1 H 2 V 1 H 1 Maximum V 1 Minimum H 2 H 1 + H 2 Maximum 1 ft. 305 mm Back to Back 90º Elb...
Page 32 - Minimum; m; Back to Back 90o Elbows
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 32 Rear Vent - Vertical Termination One Elbow Figure 7.17 Two Elbows Figure 7.18 H 1 V 1 INSTALLED HORIZONTALLY H 1 H 2 V 2 V 1 Minimum H 1 Maximum 6 in. 152 mm 2 ft. 610 mm 1 ft. 305 mm 3 ft. 914 mm 2 ft. 610 mm 5 ft. 1.5 m 3 ft....
Page 33 - c restrictions on this value EXCEPT
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 33 Rear Vent - Vertical Termination - (continued) Three Elbows Figure 7.19 Three Elbows Figure 7.20 INSTALLED HORIZONTALLY H 3 H 1 H 2 V 1 V 2 V 1 H 2 H 1 H 1 H 2 H 3 V 1 Minimum H 1 + H 2 + H 3 Maximum * * * 8 ft. 2.4 m 6 ft. 1.8...
Page 34 - A. Pipe Clearances to Combustibles; Vent Clearances and Framing; B. Wall Penetration Framing; Combustible Wall Penetration; When terminating horizontally off the top of the unit
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 34 A* B* 10 in. 12 in. C D 10 in. 12 in. A. Pipe Clearances to Combustibles WARNING! Risk of Fire! Maintain air space clearance to vent. DO NOT pack insulation or other combustibles: • Between ceiling fi restops• Between wall shie...
Page 35 - C. Install the Ceiling Firestop; MUST; DVP pipe only; SLP pipe only
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 35 C. Install the Ceiling Firestop A ceiling fi restop MUST be used between fl oors and attics. • DVP pipe only - Frame an opening 10 in. by 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/ fl oor (see Figure 8.3)...
Page 36 - D. Install Attic Insulation Shield; Flat Ceiling Installation; Vaulted Ceiling Installation
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 36 D. Install Attic Insulation Shield WARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home Technologies Inc. requires the use of an attic shield. The National Fuel Gas Code ANSI Z223.1 an...
Page 37 - Appliance Preparation; Cut the seal cap strap across the rectangles
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 37 CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal-lation. Sheet metal edges are sharp. NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a...
Page 39 - D. Securing and Leveling the Appliance
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 39 Figure 9.12 Non-combustible Board C. Installing the Non-combustible Board The factory supplied non-combustible board spans the distance from the top of the fi replace to the center of the f r a m i n g h e a d e r. T h i s b o ...
Page 40 - Attach Vent to the Firebox Assembly; The end of the pipe sections with the lanced tabs will face; Assemble Pipe Sections; Make sure that the seams are not aligned to prevent; INCORRECT; Lances
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 40 10 10 Installing Vent Pipe (DVP and SLP Pipe) A. Assemble Vent Sections (DVP Pipe Only) Attach Vent to the Firebox Assembly Note: The end of the pipe sections with the lanced tabs will face toward the appliance. Attach the fi r...
Page 41 - C. Assemble Slip Sections; Pilot hole; • Apply a bead of silicone sealant inside the female outer
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 41 B. Assemble Vent Sections (SLP Pipe Only) To attach the fi rst vent component to the starting collars of the appliance:• Attach a DVP-2SL or DVP-SLP24 adapter to the starting collar of the appliance. • Lock the vent components ...
Page 42 - E. Disassemble Vent Sections
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 42 120º Figure 10.8 Securing Vertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections E. Disassemble Vent Sections • Rotate either section (see Figure 10.10) so the seams on both pipe sections are aligned as shown...
Page 43 - F. Install Decorative Ceiling Components
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 43 F. Install Decorative Ceiling Components (SLP only) A decorative ceiling thimble can be installed on a fl at ceil- ing through which the vent passes. The decorative ceiling thimble is used to cover the fi restop. • Seal the gap...
Page 44 - G. Install Metal Roof Flashing; CAULK; H. Assemble and Install Storm Collar
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 44 G. Install Metal Roof Flashing • See minimum vent heights for various pitched roofs (Figure 10.14) to determine the length of pipe to extend through the roof. • Slide the roof fl ashing over the pipe sections extending through ...
Page 45 - I. Install Vertical Termination Cap; J. Install Decorative Wall Components (SLP; • Slide the decorative wall thimble over the last section of; Heat shields may not be; K. Heat Shield Requirements for Horizontal; • DO NOT remove the heat shields attached to the
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 45 SCREWS CAULK STORM COLLAR (1 of 3) Figure 10.18 Figure 10.18 TERMINATION CAP I. Install Vertical Termination Cap • Attach the vertical termination cap by sliding the inner collar of the cap into the inner fl ue of the pipe sect...
Page 46 - L. Install Horizontal Termination Cap (DVP; Cap Specifi cation Chart
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 46 Figure 10.20 Venting through the wall INTERIOR HEAT SHIELD OR EXTENDED HEAT SHIELD WALL SHIELD FIRESTOP HEAT SHIELD 1-1/2 IN. (38 MM) MIN. OVERLAP SHEATHING VENT DEPTH FROM BACK OF APPLIANCE TO OUTSIDE SURFACE OF EXTERIOR WALL ...
Page 47 - • Purge should be performed by qualified service; Gas Information; Gas Pressure; Minimum inlet pressure; • If substituting for these components, please consult; D. High Altitude Installations; • Close the manual shutoff valve BEFORE
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 47 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home Technologies speci fi ed and approved parts. B. Gas Press...
Page 48 - C. Standing Pilot Ignition System Wiring; NOTICE: DO NOT wire 110 VAC to the millivolt valve! This; A. Wiring Requirements; Electrical Information
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 48 Figure 12.1 Ignitor Button C. Standing Pilot Ignition System Wiring • The standing pilot ignition system wiring does not require a 110 VAC supply to operate. See Figure 12.3 • A 110 VAC junction box MUST be installed for use wi...
Page 49 - E. Electrical Service and Repair
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 49 E. Electrical Service and Repair WARNING! Risk of Shock! Label all wires prior to dis-connection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Figure...
Page 50 - F. Junction Box Installation; INSIDE
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 50 G. Wall Switch Installation for Fan (Optional) If the box is being wired to a wall mounted switch for use with a fan (See Figure 12.5): • The power supply for the appliance must be brought into a switch box. • The power can the...
Page 51 - Finishing; A. Mantel and Wall Projections; Measurement is taken from top of the opening,
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 51 13 13 Finishing A. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clear-ances as specifi ed. Framing closer than the minimums list-ed must be constructed entirely of noncombustible materials (i.e., s...
Page 53 - Remove shipping materials from inside or underneath the; C. Clean the Appliance; rebox or underneath in the control cavity.; • Save the remaining ember materials for use during; Appliance Setup
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 53 A. Remove Fixed Glass Assembly See Section 14.G. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox. C. Clean the Appliance Clean/vacuum any sawdust that may have accumulated insid...
Page 54 - F. Install the Log Assembly; Figure 1; L o g P la c e m e n t Ta b s; Handle with
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 54 F. Install the Log Assembly LOG ASSEMBLY: LOGS-6000BE 1. Release four glass clips and set the glass assembly aside. NOTE: See Step 9 when replacing the log set in an existing fi replace. 2. Carefully cut the cable tie holding t...
Page 55 - Log Placement Tabs; Owner ’s Manual
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 55 5. The grate is located in the lower cavity. Remove the screw holding the grate in place and discard the screw. 6. Position the grate into the cutout in the refractory. Hook the grate into position using the tabs on the bottom ...
Page 56 - G. Fixed Glass Assembly; Removing Fixed Glass Assembly; Air Shutter Settings; NG; Full Open; I. Air Shutter Setting; This
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 56 Figure 14.2 Fixed Glass Assembly G. Fixed Glass Assembly WARNING! Risk of Asphyxiation! Handle fi xed glass assembly with care. Inspect the gasket to ensure it is undamaged and inspect the glass for cracks, chips or scratches. ...
Page 57 - A. Standing Pilot Ignition System; Troubleshooting; ed service technician in the diagnosis of a problem and; Symptom
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 57 A. Standing Pilot Ignition System 15 15 Troubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting gu...
Page 59 - B. IntelliFire Ignition System
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 59 B. IntelliFire Ignition System Symptom Possible Cause Corrective Action 1. Pilot won’t light. The ignitor/module makes noise, but no spark. A. Incorrect wiring. Verify “S” wire (white) for sensor and “I” wire (orange) for ignit...
Page 61 - Reference Materials; A. Appliance Dimension Diagram; Location Inches
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 61 16 16 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5. Figure 16.1 Appliance Dimensions A D B C H E...
Page 62 - B. Vent Components Diagrams
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 62 B. Vent Components Diagrams Figure 16.2 DVP vent components 10-1/2 in.(267 mm) 10-7/8 in. (276 mm) 45 ° 7-3/8 in. (187 mm) 11-3/8 in.(289 mm) 1-1/4 in. (32 mm) 9-1/4 in. (235 mm) 13-1/4 in.(337 mm) 1/2 in. TYP DVP90ST (90° Elbo...
Page 63 - Horizontal Termination Cap; Max; The heat shield is designed to be; Heat
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 63 DVP-HPC1 DVP-HPC2 DVP-TRAP1 DVP-TRAP2 DVP-TRAPK2 DVP-TRAPK1 DVP-TRAP Horizontal Termination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (...
Page 66 - HORIZONTAL TERMINATION CAP; SS termination caps on top vented
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 66 B. Vent Components Diagrams (continued) DVP-HRC-SS DVP-HRC-ZC-SS HORIZONTAL TERMINATION CAP 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) 10-7/8 in. 276 mm 10-1/2 in. 267 mm 3° 87° Effective Length 5-3/4 to 8-3/8 in. 146 t...
Page 67 - Effective Height/Length
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 67 B. Vent Components Diagrams (continued) Figure 16.7 SLP Series Vent Components Effective Height/Length Pipe inches mm SLP4 4 102 SLP6 6 152 SLP12 12 305 SLP24 24 610 SLP36 36 914 SLP48 48 1219 SLP6A 2 - 6 51 - 152 SLP12A 2 - 12...
Page 69 - D. Contact Information; For the location of your nearest Heat & Glo dealer,; DO NOT DISCARD THIS MANUAL; NOTICE; • Leave this manual with
Heat & Glo • BE-41C / LP, BE-41IPIC / LP • 2105-900 Rev. P • 6/09 73 Heat & Glo, a brand of Hearth & Home Technologies Inc. 7571 215 th Street West, Lakeville, MN 55044 www.heatnglo.com D. Contact Information Please contact your Heat & Glo dealer with any questions or concerns. For t...