Page 2 - Grate
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 2 Read this manual before installing or operating this fi replace. Please retain this owner’s manual for future reference. Congratulations on selecting a Heat & Glo wood burning fi re- place. The Heat & Glo fi replace y...
Page 3 - Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07; Table of Contents
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 3 Table of Contents 1 Listing and Code Approvals 4 A. Appliance Certi fi cation . . . . . . . . . . . . . . . . . . . . . . . . . 4 2 Getting Started 5 A. Design and Installation Considerations . . . . . . . . . . . . 5B. Negat...
Page 4 - Listing and Code Approvals; cation; WARNING
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 4 1 1 Listing and Code Approvals A. Appliance Certi fi cation This fi replace system has been tested and listed in accor- dance with UL 127 standards by Underwriters Laboratories Inc. for installation and operation in the Unite...
Page 5 - Getting Started; A. Design and Installation Considerations; Asphyxiation Risk
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 5 2 2 Getting Started A. Design and Installation Considerations Draft is the pressure difference needed to vent fi replaces successfully. Considerations for successful draft include: • Preventing negative pressure• Location of ...
Page 6 - fl
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 6 Location of the fi replace and chimney will affect performance. As shown in Figure 2.1 the chimney should: • Be installed through the warm airspace enclosed by the building envelope. This helps to produce more draft, especial...
Page 7 - C. Typical Fireplace System
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 7 C. Typical Fireplace System The Heat & Glo fi replace system consists of the following: • Fireplace/integral grate/refractory/outside air system• Refractory• Chimney termination cap• Chimney system • Hearth extension • Gl...
Page 8 - CAUTION; E. Inspect Fireplace and Components; • Read all the instructions before starting the installation.; D. Tools and Supplies Needed
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 8 Before beginning the installation be sure the following tools and building supplies are available: Reciprocating saw Framing material Pliers High temp caulking material Hammer GlovesPhillips screwdriver Framing square Flat bl...
Page 9 - Framing and Clearances; A. Selecting Fireplace Location; Fire Risk
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 9 3 3 Framing and Clearances A. Selecting Fireplace Location Several options are available to you when choosing a loca-tion for your fi replace. This fi replace may be used as a room divider, installed along a wall, across a co...
Page 11 - D. Frame the Fireplace; Figure 3.4 shows a typical framing (using 2 x 4 lumber) of the; Header Height; Mantel
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 11 C. Sidewalls/Surrounds Adjacent combustible side walls must be located a minimum distance from the fi replace opening as per Figure 3.3. D. Frame the Fireplace Figure 3.4 shows a typical framing (using 2 x 4 lumber) of the f...
Page 12 - E. Construct the Chase; F. Chimney Requirements
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 12 E. Construct the Chase A chase is a vertical boxlike structure built to enclose the fi re- place and/or its vent system. Vertical chimneys that run on the outside of a building must be installed inside a chase. Construction ...
Page 13 - A. Install the Outside Air Kit; Risk of Smoke Spillage; Sharp Edges
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 13 A. Install the Outside Air Kit This fi replace will operate correctly only if adequate ventila- tion is provided to allow proper draft to the fi replace system. See Section 2. The outside air kit is supplied with this fi rep...
Page 15 - B. Secure the Fireplace; • Position the Fireplace; • Level the Fireplace; • Place the Protective Metal Hearth Strips
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 15 B. Secure the Fireplace • Position the Fireplace This fi replace may be placed on either a combustible or noncombustible continuous fl at surface. Follow the in- structions for framing in Section 3.D. Slide the fi replace in...
Page 16 - Termination Cap; Chimney Assembly
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 16 NOTE: • Chimney performance may vary. • Trees, buildings, roof lines and wind conditions affect performance. • Chimney height may need adjustment if smoking or overdraft occurs. Chimney must extendbeyond combustibleroof stru...
Page 17 - A. Chimney Requirements
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 17 A. Chimney Requirements Vertical distances are measured from the base of the fi re- place as shown in Figure 5.2. To determine the chimney components needed to complete your particular installation, follow the steps below: •...
Page 19 - C. Assemble the Chimney Sections; D. Install the Ceiling Firestops
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 19 Note: The ceiling fi restop MUST be nailed to the bottom of the ceiling joists EXCEPT when the space above is uninsulated and the attic insulation shield is not being used (see Figure 5.5). When the attic insulation shield i...
Page 20 - overlap; E. Install the Attic Insulation Shield
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 20 6 Tabs bent in 90° Tabs bent in to rest against pipe Attic Insulation Shield Ceiling Firestop 13 in. (330 mm) 17 in. (432 mm) diameter Insulation Insulation Pipe Pipe Figure 5.7 Install Attic Insulation Shield Above the Ceil...
Page 21 - • Secure offsets with screws (not to exceed; Keep chimney sections from separating or twisting.; G. Secure the Chimney
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 21 Ceiling Firestop Straps Optional Additional Support Joint Band (Optional) Figure 5.9 Secure the Chimney Fire Risk • Secure offsets with screws (not to exceed 3/4 in./19 mm in length). WARNING • Secure returns with strapping....
Page 22 - Termination Caps Staggered Height; Complete the Enclosure; A. Chimney Termination; • Must have a cap approved and listed for this; and; at least 2 ft (610 mm) above any portion of the roof within 10 ft
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 22 Slanted Roofs Flat Roofs Chimney mustextend 3 ft (.9 m)above the roof Chimney must extend 2 ft (.6 m)above any portion of the roofwithin 10 ft (3 m) of the chimney Chimney mustextend 3 ft (.9 m)above the roof Chimney must ex...
Page 23 - Mark the Exit Point of the Roof; Uniform Building Code; Assemble the Chimney Sections Through the
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 23 Figure 6.3 Ceiling/Attic Construction Fire Risk • Must maintain 2 in. (51 mm) air clearance to insulation and other combustible materials. WARNING Mark the Exit Point of the Roof Locate the point where the chimney will exit ...
Page 24 - C. Install the Termination Cap
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 24 Termination Cap Storm Collar Slope Downward Turn-down Drip Edge Chase(Chimney) 2 in. (51 mm) Collaron Chase Top Caulk .018 (26 ga) min.GalvanizedChase Top Figure 6.4 Chase Top Construction 2 in. (51 mm) min. collar 6 in. (15...
Page 26 - National Fuel; Accessories
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 26 A. Gas Log/Lighter Provisions A certi fi ed gas log lighter or decorative gas log set can be installed in this fi replace. • Maximum input is 100,000 BTU/hr.• Decorative gas appliance must be certi fi ed to ANSI Z21.60 “Stan...
Page 27 - Finishing
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 27 8 8 Finishing A. Hearth Extension A hearth extension must be installed with all fi replaces to protect the combustible fl oor in front of the fi replace from both radiant heat and sparks. See Figures 8.1 -8.3. 2 in. (51 mm) ...
Page 28 - B. Finishing Material
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 28 Metal strips 2 in. (51 mm) under the edges of the fireplace and must extend beyond the front and side openings by 2 in. (51 mm) 1 in. (25 mm) overlap Figure 8.2 Positioning the Protective Metal Hearth Strips A B C Figure 8.3...
Page 30 - Operating Instructions; A. General Information; Damper Control; Hot glass will cause burns.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 30 9 9 Operating Instructions A. General Information Fireplaces, as well as other woodburning appliances, have been used safely for many years. It has been our experience that most problems are caused by improper installation a...
Page 31 - C. Clear Space Near the Fireplace
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 31 D. Flue Damper The fl ue damper must be in full open position, and is oper- ated by moving the handle up toward the top of the fi replace. Before lighting the fi re, verify this by looking up from the in- side of the fi repl...
Page 32 - Seasoning
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 32 G. Grate The factory installed integral grate must be used to hold the logs from falling out of an open fi replace and to allow air to pass between the burning logs. It is important to keep the fi re off the hearth and to al...
Page 34 - Troubleshooting; A. Understanding Vent Problems
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 34 10 10 Troubleshooting Another appliance in home also exhaustingair (furnace, fan, dryer, etc.)? Air register fromfurnace nearfireplace? Doors openingand closing?Window closedfor start-up? Outside airclosed? Overhead fanopera...
Page 35 - Possible Causes of Condition; B. Diagnostics and Problem Solving; Diagnostic Questions; Possible Causes of Condition; Solutions; I can’t get a good
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 35 Diagnostic Questions Possible Causes of Condition Solutions Is the damper open? • No draft Open damper. Is there enough paper/starter? • Insuf fi cient heat to ignite kindling Use more paper/starter. Is there enough kindling...
Page 36 - I smell smoke in the house during operation. What’s causing that?
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 36 Diagnostic Questions Possible Causes of Condition Solutions Do you have glass doors? • Need to slow air intake Add glass doors. What is the condition of the wood? • Extremely dry wood Mix in less seasoned wood after fi re es...
Page 37 - C. Firebox Refractory
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 37 A. Disposal of Ashes Ashes should be placed in a metal container with a tight- fi t- ting lid. The closed container of ashes should be placed on a noncombustible fl oor or on the ground, well away from all combustible materi...
Page 38 - D. Maintenance Task List; When cleaning glass door:; Inspect
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 38 Fire Risk • Do not use chimney cleaners or fl ame colorants in your fi replace. Will corrode chimney. WARNING D. Maintenance Task List Asphyxiation RiskFire Risk Annual inspection by qualified technician recommended. Check: ...
Page 39 - Reference Materials; A. Fireplace Dimensions
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 39 12 12 Reference Materials A. Fireplace Dimensions 42" 36"40" 7" 12" 40" 24" GASKNOCKOUT GASKNOCKOUT ELECTRICALKNOCKOUTFOR ST36C 42" 36"40" 12" 24" 11" 20" FRONT VIEW - ...
Page 40 - B. Fireplace Components; Description
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 40 B. Fireplace Components GR3 Integral Grate Bi-fold Glass Doors 16 in. (406 mm) 52 in. (1321 mm) 1/2 in. (13 mm) HX3 Hearth Extension (SIDE OF FIREPLACE) AK17/AK18 Outside Air Kit TK53B Trim Kit Catalog # Description PIER-40 ...
Page 41 - C. Chimney Components; ID4 Insulated Duct; Outside Diameter
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 41 C. Chimney Components The following pictures show only those chimney components which may be safely used with this fi replace. 13 in. (330 mm) 14 in. (356 mm) 14 in. (356 mm) 5-1/4 in. (133 mm) 4 in. (102 mm) CAK5A Chimney A...
Page 44 - European Copper Caps
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 44 CT3-Queen CT3-Bishop CT3-Pawn CT3-Knight CT3-King 21 in. (533 mm) 47-3/4 in. (1213 mm) 24 in. (610 mm) 18-1/4 in. (464 mm) 41-1/8 in. (1045 mm) 20 in. (508 mm) 16 in. (406 mm) 38-3/8 in. (975 mm) 16 in. (406 mm) 21 in. (533 ...
Page 45 - Woodburning Termination Cap; Radiation Shield or
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 45 Woodburning Termination Cap Shroud TS345 / 445 (Top Vent) TR342 / 344 TR442 / 444 TR342 / 344 TV TR442 / 444 TV (with TR-TVK installed) TR11 / 11T TR11 / 11T TV (with TR-TVK installed) OPEN TOP with solid sides and 3 in. ope...
Page 46 - Service Parts; Ending Manufacturing Date: Active
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 46 D. Service Parts Service Parts DiagramMulti-Sided Woodburning Fireplace Service Parts BAY-40 Beginning Manufacturing Date: 2/4/04 Ending Manufacturing Date: Active 1 2 3 11 10 14 5 9 6 12 4 13 8 7
Page 47 - Description of Part
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 47 Service Parts BAY-40 Beginning Manufacturing Date: N/A Ending Manufacturing Date: 08/01/01 Service Parts ListMulti-Sided Woodburning Fireplace # Description of Part Part Number Qty. req. 1 Top Standoff 11864i 4 2 Starter Sec...
Page 50 - This page intentionally left blank.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 50 This page intentionally left blank.
Page 51 - WARRANTY
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 51 E. Limited Warranty WARRANTY FOR HEAT & GLO FIREPLACES The limited warranty will not become effective until you have mailed the completed warranty card to: Hearth & Home Technologies Inc. 20802 Kensington Blvd., Lake...
Page 52 - – NOTES –; F. Contact Information; DO NOT DISCARD THIS MANUAL; • I m p o r t a n t; DO
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07 52 Please contact your Heat & Glo dealer with any questions or concerns. For the number of your nearest Heat & Glo dealer, please visit www.heatnglo.com. – NOTES – F. Contact Information DO NOT DISCARD THIS MANUAL CAUTI...