Page 2 - SAFETY AND WARNING INFORMATION
Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05 2 These units MUST use one of the vent systems described in the Installing the Fireplace section ofthe Installers Guide . NO OTHER vent systems or components MAY BE USED. This gas fireplace and vent assembly MUST be vented directly...
Page 3 - TABLE OF CONTENTS; Safety and Warning Information
Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05 3 TABLE OF CONTENTS Safety and Warning Information . ............................................... 2 Service Parts Lists . .................................................................... 4 Section 1: Approvals and Codes . .....
Page 4 - Part number list on following page.; Log Set Assembly; Service Parts
Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05 4 Part number list on following page. 6 Log Set Assembly 5 4 2 1 3 11 1 0 1 2 8 7 9 1 3 (NG, LP) Exploded Parts Diagram Service Parts Beginning Manufacturing Date: 4-01Ending Manufacturing Date: ______ 6000TV-OAK, 6000TV-OAK-IPI
Page 5 - Service Parts List
Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05 5 Service Parts List ITEM COMMON PARTS SERIAL # PART NUMBER 1 Burner NG, LP SRV383-338A 2 Glass Door Assembly GLA-6TROC 3 Surround PRE 002324021POST 002324021 385-1302026-108 4 Hood SRV60-143-BK 5 Log Grate 383-360A 6 Oak Log Set A...
Page 6 - Intermittent Pilot Ignition
Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05 6 (NG, LP) Exploded Parts Diagram Service Parts Beginning Manufacturing Date: 4-01 Ending Manufacturing Date: ______ Intermittent Pilot Ignition Valve Assembly ITEM D ESCR IPTION SERIAL # PART N O. 1 Flex Ball Valve Assembly 302-32...
Page 7 - Standing Pilot Ignition
Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05 7 (NG, LP) Exploded Parts Diagram Service Parts 6000TV-OAK Beginning Manufacturing Date: 4-01 Ending Manufacturing Date: ______ Standing Pilot Ignition Valve Assembly 5 2 9 10 3 7 1 4 8 6 ITEM DESCRIPTION SERIAL # PART NUMBER 1 ON/...
Page 8 - Appliance Certification; The Heat & Glo fireplace models discussed in this; Certification; Underwriters Laboratories; Installation Codes; Approvals and Codes; High Altitude Installations
Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05 8 Appliance Certification The Heat & Glo fireplace models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories. Certification MODEL: 6000TV-OAK LABORATORY: Und...
Page 9 - Getting Started; Introducing the Heat & Glo Gas Fireplaces; Pre-install Preparation; Do not install any
Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05 9 2 Getting Started Introducing the Heat & Glo Gas Fireplaces Heat & Glo B-type vent gas fireplaces are designed to op-erate with all exhaust gases expelled to the outside of thebuilding. The information contained in this I...
Page 11 - Installing the Fireplace; Step 1. Locating the Fireplace; * The clearance to the ceiling is measured from the top; Constructing the Chase; from the
Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05 11 3 Installing the Fireplace Step 1. Locating the Fireplace The diagram shows space and clearance requirements forlocating a fireplace within a room. A B C D E 42” 22” 36” 51” 72” Minimum Clearances from the Fireplace to Combustib...
Page 12 - Negative Pressure warning; : When negative pressure is; This may create a dangerous carbon; Stack effect in the building.; Air Damper; Framing Dimensions; Step 2. Framing the Fireplace
Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05 12 Step 3. Negative Pressure Make-up Air Negative Pressure warning : When negative pressure is present, an atmospherically vented fireplace (with a drafthood) may not function properly and it may down draft. Inthe case of a gas app...
Page 13 - and
Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05 13 ! ! Step 4. Installing the Vent System A. Vent System Approvals Model 6000TV-Oak is approved to use 6-inch (152mm)diameter B-type vent. B-type vent must be used when thevent system is within combustible construction. These model...
Page 14 - Step 6. The Gas Control Systems
Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05 14 ! C. Bedroom Installation in Canada This model MUST NOT be vented into a vent system in- stalled exterior to a building. The part of the vent systemabove the roof line can be exterior to the building. D. Vent Termination WARNING...
Page 15 - Figure 9. Gas Supply Line; Step 7. The Gas Supply Line; Pressure; STANDING PILOT
Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05 15 Figure 9. Gas Supply Line • Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal between thepipe and the outer casing. • At the gas line access hole the gap between the supply pipin...
Page 16 - Step 9. Wiring the Fireplace; This appliance; DOES NOT; the appliance connect the wire to the ON/OFF switch pigtails.
Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05 16 Step 9. Wiring the Fireplace NOTE: Electrical wiring must be installed by a licensedelectrician. CAUTION: DISCONNECT REMOTE CONTROLS IF AB-SENT FOR EXTENDED TIME PERIODS TO PREVENTACCIDENTAL FIREPLACE OPERATION. For Standing Pil...
Page 17 - appliance connect the wire to the ON/OFF switch pigtails.
Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05 17 For Intermittent Pilot Ignition (IPI) Wiring 3 Volt Transformer This appliance comes with a 3 volt transformer. The trans-former plugs into the junction box and the two leads pluginto the green control module (see Figure 12). Ap...
Page 19 - Step 12. Before Lighting the Fireplace; Step 13. Lighting the Fireplace
Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05 19 Glass Specifications: TEMPERED Figure 16. Placement of the Ember Material Figure 15. Glass Assembly Step 12. Before Lighting the Fireplace Before lighting the fireplace, be sure to do the following: Remove all paperwork from und...
Page 20 - Maintaining and Servicing Your Fireplace; Fireplace Maintenance; Placing Ember Material
Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05 20 4 Maintaining and Servicing Your Fireplace Fireplace Maintenance Although the frequency of your fireplace servicing and main-tenance will depend on use and the type of installation, youshould have a qualified service technician ...