Heat & Glo 550TRSI-AUF - Manuals
Heat & Glo 550TRSI-AUF – Manual in PDF format online.
Manuals:
Manual Heat & Glo 550TRSI-AUF
Summary
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 2 MODELS: 550TRSI-AUF, 550TRSILP-AUF ARE SAI GLOBAL APPROVED FOR NATURAL GAS, PROPANE OR BUTANE AS A BALANCED FLUE HEATER. Refer to the appliance data plates for gas consumptions and pressures.Installation of this appliance should ...
3 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on fireplace: _____________________ Dealership purchased from...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 4 FOR YOUR SAFETY This appliance is designed to operate on LPG IF YOU SMELL GAS: • Turn off as supply at bottle• Extinguish all naked fl ames• Do not operate any electrical appliances• Ventilate the area• Check for leaks as detaile...
5 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. •...
7 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 C. Limited Lifetime Warranty AUSTRALIAN WARRANTY INFORMATION Warranty information in the attached manual is for international markets, not Australia. For Australian warranty information, please see below. Hearth & Home Techno...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 8 Warranty Period Heat & Glo Manufactured Appliances and Venting Components Covered Parts Labor Gas Wood Pellet EPA Wood Coal Electric Venting 5 years 1 years X X Castings & baffl es 7 years 3 years X X X Manifold tubs HEAT...
9 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 • Non Heat & Glo venting components, hearth components or other accessories used in conjunction with the appliance. • Any part of a pre-existing fi replace system in which an insert or a decorative gas appliance is installed....
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 10 A. Appliance Certification 1 Listing and Code Approvals MODELS: 550TRSI-AUF, 550TRSILP-AUF LABORATORY: SAI Global TYPE: Gas Space Heating Appliance STANDARD: AS4553-2008 C. High Altitude Installations NOTICE: If the heating valu...
11 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 Figure 2.1 General Operating Parts B. Your Fireplace WARNING! DO NOT operate fireplace before read- ing and understanding operating instructions. Failure to operate fireplace according to operating instructions could cause fire ...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 12 D. Clear Space WARNING! DO NOT place combustible objects in front of the fireplace or block louvers. High temperatures may start a fire. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth....
13 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 I. Lighting Instructions (IPI) 1. This appliance is equipped with an ignition device which automatically lights the burner. DO NOT try to light the burner by hand. 2. Wait five (5) minutes to clear out any gas. Then smell for ga...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 14 Note: If the module is in LOCK-OUT mode, resetting the circuit breaker to the appliance will also reset the module. Note: For units installed in Australia, the residence’s 220/240 wall outlet to which this appliance’s power cord...
15 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 K. After Fireplace is Lit Initial Break-in Procedure• The fireplace should be run three to four hours continuously on high. • Turn the fireplace off and allow it to completely cool.• Remove fixed glass assembly. See Section 9.E....
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 16 Glass Cleaning Frequency: Seasonally By: Homeowner Tools Needed : Protective gloves, glass cleaner, drop cloth and a stable work surface. CAUTION! Handle fixed glass assembly with care. Glass is breakable. • Avoid striking, scra...
17 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 B. Maintenance Tasks-Qualified Service Technician The following tasks must be performed by a qualified ser- vice technician. Gasket Seal and Glass Assembly Inspection Frequency: Annually By: Qualified Service Technician Tools ne...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 18 A. Typical Appliance System NOTICE: Illustrations and photos reflect typical installations and are for design purposes only. Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual Figure 4...
19 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to op- erate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside of the bui...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 20 5 Framing and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1). WARNING! Risk of Fire or Burns! Provide adequate...
21 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should be enclosed inside the chase. NOTICE: Treatment of ceilin...
23 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 D. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clear - ances as specified. Framing or finishing material closer than the minimums listed must be constructed entirely of noncom- bustible materials (...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 24 A. Vent Termination Minimum Clearances Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening 6 Termination Locations Fire Risk.Maintain vent clearance to combustibles as specified.• DO NOT pack air space with insulatio...
25 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 Figure 6.3 Minimum Clearances for Termination NOTES: 1. All distances are measured vertically or horizontally along the wall to a point in line with the nearest part of the terminal. 2. Prohibited area below electricity meter or...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 26 A. Approved Pipe This appliance is approved for use with Hearth & Home Technologies DVP and SLP venting systems. Refer to Section 16.B for vent component information. DO NOT mix pipe, fittings or joining methods from differ-...
27 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 Example: DVP pipe 3 ft. (1 m) min. vertical = 11 ft. (3.35 m) max. horizontal SLP pipe 7 ft. (2.13 m) min. vertical = 11 ft. (3.35 m) max. horizontal Figure 7.4 Top Vent - Horizontal Termination Fire Risk. Explosion Risk.Do NOT ...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 28 Top Vent - Horizontal Termination - (continued) Figure 7.5 Two Elbows INSTALLED HORIZONTALLY H 1 H 2 V 1 V 1 Minimum H 1 + H 2 Maximum Elbow only Not allowed 6 in. 152 mm 1 ft. 305 mm 1 ft. 305 mm 2 ft. 610 mm 2 ft. 610 mm 4 ft....
29 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 Figure 7.6 Three Elbows H 2 H 1 V 2 V 1 Note: A 6 in. (152 mm) section of straight flue must be attached to the heater before a 90° elbow. USE SLP SERIES COMPONENTS ONLY V 1 Min. H 1 Max. V 2 Min. H 2 Max. 6 in. 152 mm 1 ft. 305...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 30 Top Vent - Vertical Termination This model is approved to use DVP-Series flue pipe com- ponents. A DVP-TVHW vertical Termination Cap must be used to terminate flue systems in a vertical position.Approved flue system components a...
31 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 MODEL 550TRSI-AUF 550TRSILP-AUF FLUE TERMINATION APPROVALS DVP-TRAP2 HORIZONTAL TERMINATION CAP DVP-FBHT HORIZONTAL TERMINATION CAP DVP-TVHW VERTICAL TERMINATION CAP Flue System Approvals And Installations These models have flue...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 32 Figure 7.10 H 1 V 1 V 2 USE SLP SERIES COMPONENTS ONLY Two Elbows Top Vent - Vertical Termination - (continued) V 1 H 1 Maximum V 2 V 1 + V 2 Min. Elbow only Not allowed * * * 6 in. 152 mm 2 ft. 610 mm * * * 1 ft. 305 mm 4 ft. 1...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 34 Rear Vent - Horizontal Termination Figure 7.13 No Elbow One 45º Elbow H 1 Do not use a 45º elbow in corner installations. Use two 90º elbows instead. Figure 7.12 USE DVP SERIES COMPONENTS ONLY USE DVP SERIES COMPONENTS ONLY H 1 ...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 36 Rear Vent - Vertical Termination One Elbow Figure 7.16 Two Elbows Figure 7.17 V 1 H 1 INSTALLED HORIZONTALLY H 1 H 2 V 1 USE DVP SERIES COMPONENTS ONLY USE DVP SERIES COMPONENTS ONLY V 1 Minimum H 1 Maximum 1 ft. 305 mm 3 ft. 91...
37 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 Rear Vent - Vertical Termination - (continued) Three Elbows Figure 7.17 Three Elbows Figure 7.18 INSTALLED HORIZONTALLY H 3 H 1 H 2 V 1 V 2 V 1 H 2 H 1 USE DVP SERIES COMPONENTS ONLY USE DVP SERIES COMPONENTS ONLY H 1 H 2 H 3 V ...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 38 A. Pipe Clearances to Combustibles WARNING! Risk of Fire! Maintain air space clearance to vent. DO NOT pack insulation or other combustibles: • Between ceiling firestops • Between wall shield firestops • Around vent systemFailur...
39 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 C. Install the Ceiling Firestop A ceiling firestop MUST be used between floors and attics.• DVP pipe only - Frame an opening 10 in. x 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/floor (see Figure 8.3). • SLP...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 40 Figure 8.5 Attic Insulation Shield Figure 8.6 Heat Zone ® Knockout E. Installing the Optional Heat-Zone ® -240V Kit • Remove the knockout from the fireplace and discard it (see Figure 8.6). • Center the duct collar around the ex...
41 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp.NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a ...
43 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 Figure 9.16 Proper Positioning and Securing of an Appliance NAILING TABS (BOTH SIDES) PILOT HOLES Figure 9.14 Non-combustible Board C. Installing the Non-combustible Board The factory supplied non-combustible board must be used....
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 44 Natural Gas Propane Butane 550TRSI-AUF 11.13 mm N/A N/A 550TRSILP-AUF N/A Full Open Full Open Figure 9.17 Fixed Glass Assembly GLASS ASSEMBLY LATCHES (BOTH BOTTOM AND TOP) E. Covers Removal For Servicing Control Compartment Acce...
45 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 10 Installing Vent Pipe (DVP and SLP Pipe) A. Assemble Vent Sections (DVP Pipe Only) Attach Vent to the Firebox Assembly Note: The end of the pipe sections with the lanced tabs will face toward the appliance. Attach the first pi...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 46 B. Assemble Vent Sections (SLP Pipe Only) To attach the first vent component to the starting collars of the appliance:• Lock the vent components into place by sliding the pipe section onto the collar. • Align the seam of the pip...
47 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 120º Figure 10.8 Securing Vertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections E. Disassemble Vent Sections • Rotate either section (see Figure 10.10) so the seams on both pipe sections are aligned as shown ...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 48 10 in. (254 mm) 12 in. (305 mm) INTERIOR WALL SHIELD Figure 10.13 Flue Pipe & Firestop Figure 10.14 Hole and New Framing Members For Vertical Runs - One firestop is REQUIRED at the hole in each ceiling through which the flue...
49 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 Figure 10.15 Ceiling Firestop (Ceiling Side) Figure 10.16 Attic Firestop CEILING CEILING FIRESTOP RAFTER NAILS (4 REQUIRED) JOIST CEILING FIRESTOP CEILING NAILS (4 REQUIRED) If the area above the ceiling IS an attic, position an...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 50 J. Install Metal Roof Flashing • See minimum vent heights for various pitched roofs (Figure 10.19) to determine the length of pipe to extend through the roof. • Slide the roof flashing over the pipe sections extending through th...
51 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 CAULK K. Assemble and Install Storm Collar CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. • Connect both halves of the storm colla...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 52 11 Gas Information A. Gas Pressure Requirements WARNING! Risk of Explosion! An in-line regulator MUST be installed if the gas pressure exceeds 3.7 kPa. Failure to install a regulator could damage valve. Pressure requirements for...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 54 12 Electrical Information A. Wiring Requirements NOTICE: This appliance must be installed by a qualified electrician in accordance with the relevant national and local regulations. • Wire the appliance junction cord to 220-240 V...
55 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 BLUE BROWN GREEN/ YELLOW Figure 12.2 D. Blower These heaters have a factory installed fan and electrical junction cord. These components are located behind the lower door.Use of the fan requires that the Junction cord (factory i...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 56 Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions:• Installation and use of any damaged system component.• Modification of the system component.• Installat...
57 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 5. Close the housing door. See Figure 12.7. 4. Place remote control inside housing. See Figure 12.6. Figure 12.6 Remote in Housing Installation of Remote Control Housing CAUTION! Risk of Fire! DO NOT install damaged or modified ...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 58 Figure 12.7 Mounting Remote Control Housing AUX300CE Module Installation • Insert the 4 hole harness from the AUX300CE module into the 4 pin plug on the control module. See Figure 12.8. Fan Installation • Insert the 3 prong plug...
59 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 FIREPLACE STATUS THERMOSTAT THERMOSTAT DESIRED TEMP SETTING FLAME HEIGHT FAN SPEED ADJUSTABLE AUXILIARY ADJUSTABLE OUTPUT (ON/OFF) TIMER DISPLAY/FUNCTION ROOM TEMP DISPLAY FUNCTION LEVEL INDICATOR LOW BATTERY INDICATOR TRANSMISS...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 60 About ON Mode • All functions can be accessed when the remote control is in the ON mode. • Only active functions will be displayed when the remote control is in the ON mode. For example: if the fan is the only function that’s ac...
61 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 Adjusting Thermostat • Press the MENU button to activate the menu. • Using the UP and DOWN arrows highlight the THERMO icon and press SELECT . • Use the UP and DOWN arrows to turn the THERMO ON or OFF , then press SELECT (the SE...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 62 Frequently Asked Questions/Troubleshooting Symptom Possible Cause Corrective Action Remote control will not transmit Batteries Verify batteries are functional and installed correctly. Remote control is in Child Lock mode Disenga...
63 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 13 Finishing A. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clear - ances as specified. Framing closer than the minimums list - ed must be constructed entirely of noncombustible materials (i.e., st...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 64 A. Remove Fixed Glass Assembly See Section 9.E. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the firebox. C. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside t...
65 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 E. Log Placement Instructions Log Assembly: LOGS-550TRSAUD CAUTION: Logs are fragile! Carefully remove the logs from the packaging. LOG #2 (SRV347-703): Place log #2 so that its left edge sits against the left front grate corner...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 66 LOG #4 (SRV278-705): Position log #4 between log #1 and the locating tab on the fourth grate tine. Push its left hand side back to the locating tab as the grate tine. 4 4 5 5 LOG #3 (SRV349-704): Position log #3 so that its righ...
67 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 LOG #7 (SRV484-703): Place log #7 on the groove in log #2 with its rear top on log #1 and front top resting on log #5. LOG #8 (SRV347-701): Hook log #8 on the right hand corner grate tine and rest its rear on log #1 as shown. 7 ...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 68 15 Troubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualified service te...
69 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 Troubleshooting (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot flame has been lit, flame rectifica...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 70 16 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5. Figure 16.1 Appliance Dimensions Location Inches...
71 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 B. Maintenance Tasks Inspect Maintenance Tasks Doors 1. Inspect for scratches, dents or other damage and repair as necessary.2. Verify no obstructions to airflow.3. Verify maintenance of proper clearance to combustible household...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 72 C. Vent Components Diagrams Figure 16.3 DVP vent components Pipe Effective Length Inches Millimeters DVP4 4 102 DVP6 6 152 DVP12 12 305 DVP24 24 610 DVP36 36 914 DVP48 48 1219 DVP6A 3 to 6 76 to 152 DVP12A 3 to 12 76 to 305 DVP1...
73 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 C. Vent Components Diagrams ( continued ) Figure 16.4 DVP vent components DVP-TRAP2 DVP-TRAP2 Horizontal Termination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by ...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 74 DVP-TRAPFL Flashing DVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination Cap Fire Risk. • When using DVP-HRC-SS and DVP-HRC-ZC- SS termination caps on top vented fireplaces, a 6 inch (152 mm) minimum vert ical vent section is require ...
75 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 B. Vent Components Diagrams (continued) Figure 16.6 SLP Series Vent Components 8-3/4 in. 222 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 6 in. 152 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 9-7/8 in. 251 mm 6-1/2 in. 165 mm 9-1/4 in. 235 mm ...
77 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 D. Service Parts Beginning M anufacturing Date: July 2010 Ending M anufacturing Date: ______ 550TRSI-AUF, 550TRSILP-AUF Log Set Assembly IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 78 Service Parts Beginning M anufacturing Date: July 2010 Ending M anufacturing Date: ______ 550TRSI-AUF, 550TRSILP-AUF #19 Valve Assembly IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your ...
79 Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 Service Parts List 550TRSI-AUF, 550TRSILP-AUF IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual m...
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. N • 5/12 80 E. Contact Information Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer, please visit www.heatnglo.com. - NOTES - __________________________________...
Heat & Glo Manuals
-
Heat & Glo SL-550TV-IPI-E
Manual
-
Heat & Glo CF750ENH
Manual
-
Heat & Glo ST-HV-IPI
Manual
-
Heat & Glo 6000GLX-IPILP-S/-R
Manual
-
Heat & Glo st-42tvfl
Manual
-
Heat & Glo 7000XLS
Manual
-
Heat & Glo 8000TV-OAK-IPI
Manual
-
Heat & Glo EM-415 - 36
Manual
-
Heat & Glo 350TRSILP-AUF
Manual
-
Heat & Glo Exclaim-50
Manual
-
Heat & Glo 6000 Series
Manual
-
Heat & Glo XLR-PLUS-N-AU
Manual
-
Heat & Glo 8000CFLP-OAKIPI
Manual
-
Heat & Glo BE-41C
Manual
-
Heat & Glo VRT-GY-P-AUB
Manual
-
Heat & Glo 6000CL-IPI-S
Manual
-
Heat & Glo ST-36TRLP-IPI
Manual
-
Heat & Glo SL-550TV-D
Manual
-
Heat & Glo 6000GL-IPILP-S
Manual
-
Heat & Glo BW36
Manual