Page 2 - before leaving the installation site.; PROVED FOR NATURAL GAS, PROPANE OR
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 2 PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING THIS APPLIANCE. IMPORTANT: Read all instructions carefully before starting installation. Failure to follow these installation instructions may result in a possible fire hazard and will void the...
Page 3 - Listing Label Information/Location; We recommend that you record the following pertinent; Homeowner Reference Information; Read this manual before installing or operating this appliance.; SAMPLE
3 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on fireplace: _____________________ Dealer...
Page 4 - Safety Alert Key:; Used to address practices not related to personal injury.; Table of Contents; User Guide
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 4 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • CAUTION! Indica...
Page 6 - AUSTRALIAN WARRANTY INFORMATION; All Parts and Material Except; B. Limited Lifetime Warranty
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 6 AUSTRALIAN WARRANTY INFORMATION Warranty information in the attached manual is for international markets, not Australia. For Australian warranty information, please see below. Hearth & Home Technologies Inc (HHT) 7571 215th Street West, Lake...
Page 8 - charges for parts; This warranty is void if:; cracking and discoloration of steel or enamel fi nishes.; HOW TO CLAIM; you originally purchased the product.; Melbourne; Perth; Fireplace Corner; Sydney; Jetmaster
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 8 • Non Heat & Glo venting components, hearth components or other accessories used in conjunction with the appliance. • Any part of a pre-existing fi replace system in which an insert or a decorative gas appliance is installed. • Removal, inst...
Page 9 - A. Appliance Certification; Listing and Code Approvals; C. Gas Pressure Requirements; SAI GLOBAL; D. High Altitude Installations; Standard Test Method for Behavior of Materials in a; F. Combustible Materials Specification; The Heat & Glo gas appliances discussed in this Installer’s; B. Additional Related Standards; The installation must comply with these installation instruc-; Natural Gas
9 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 A. Appliance Certification 1 Listing and Code Approvals C. Gas Pressure Requirements Pressure requirements for SOHO-N-AUB fireplace are shown in table below.Two taps are provided on the right hand side of the gas control for a test gauge connect...
Page 10 - Operating Instructions; WARNING! DO NOT operate fireplace before read-; A. Gas Fireplace Safety; WARNING; This appliance has been supplied with an integral barrier; HOT SURFACES
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 10 Figure 2.1 General Operating Parts DECORATIVE DOORS (NOT SHOWN) SECTION 2.D. FIXED GLASS ASSEMBLY (NOT SHOWN) SECTION 9.B. MANTEL SECTION 5.D HEARTH CLEAR SPACE SECTION 2.C. GRATE 2 Operating Instructions User Guide B. Your Fireplace WARNING! D...
Page 11 - E. Fixed Glass Assembly; have a; WARNING! Risk of Fire or Asphyxiation! DO NOT; D. Decorative Doors and Fronts; This fireplace has been supplied with an integral
11 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 C. Clear Space WARNING! DO NOT place combustible objects in front of the fireplace or block louvers. High temperatures may start a fire. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth. Heat may damage...
Page 12 - NOT FOR USE; DO NOT CONNECT LINE VOLT-; Final inspection by
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 12 H. Lighting Instructions (IPI) 1. This appliance is equipped with an ignition device which automatically lights the burner. DO NOT try to light the burner by hand. 2. Wait five (5) minutes to clear out any gas. Then smell for gas, including nea...
Page 13 - I. Control Module Operation
13 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 Note: If the module is in LOCK-OUT mode, resetting the circuit breaker to the appliance will also reset the module. Figure 2.3 Control Module I. Control Module Operation 1. The control module has an ON/OFF/REMOTE selector switch that must be se...
Page 14 - J. After Fireplace is Lit; continuously on high.; K. Frequently Asked Questions; ISSUE
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 14 J. After Fireplace is Lit Initial Break-in Procedure• The fireplace should be run three to four hours continuously on high. • Turn the fireplace off and allow it to completely cool.• Remove fixed glass assembly. See Section 9.B.• Clean fixed gl...
Page 15 - Glass Cleaning; Tools Needed; CAUTION! Handle fixed glass assembly with care.; Note; Maintenance and Service; The fireplace should be turned; Tools needed; Remote Control; Any safety screen or guard removed for servicing must be
15 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 Glass Cleaning Frequency: Seasonally By: Homeowner Tools Needed : Protective gloves, glass cleaner, drop cloth and a stable work surface. CAUTION! Handle fixed glass assembly with care. Glass is breakable. • Avoid striking, scratching or slammi...
Page 17 - Burner Ignition and Operation; DO
17 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 Burner Ignition and Operation Frequency: Annually By: Qualified Service Technician Tools needed: Protective gloves, vacuum cleaner, whisk broom, flashlight, voltmeter, indexed drill bit set, and a manometer.• Verify burner is properly secured a...
Page 18 - A. Typical Appliance System; drawn to scale. Actual product may vary from pictures in manual; Getting Started; Installer Guide
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 18 A. Typical Appliance System NOTICE: Illustrations and photos reflect typical installations and are for design purposes only. Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual Figure 4.1 Typical Syste...
Page 19 - Read all of the instructions before starting the instal-; DO NOT i; C. Tools and Supplies Needed; Hearth & Home Technologies disclaims any responsibility for,; Any such action may cause a fire hazard.; DO NOT; Improper installation, adjustment, alteration, service or
19 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to op- erate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside of the building. No additi...
Page 20 - Framing and Clearances; A. Selecting Appliance Location; When selecting a location for the appliance it is important to; Inches; NOTE: For actual appliance dimensions refer to Sec-
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 20 5 Framing and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1). WARNING! Risk of Fire or Burns! Provide adequate clearance aroun...
Page 21 - B. Constructing the Appliance Chase; CLEARANCES TO COMBUSTIBLES
21 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should be enclosed inside the chase. NOTICE: Treatment of ceiling firestops and ...
Page 22 - D. Mantel and Wall Projections; Comply with all minimum clear-; Combustible Mantels; No mantels are allowed when using Studio-CE fronts.; Note: All dimensions are shown in millimeters
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 22 D. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clear- ances as specified. Framing or finishing material closer than the minimums listed must be constructed entirely of non- combustible materials (i.e., steel studs...
Page 23 - A. Vent Termination Minimum Clearances; Termination Locations; DO NOT; pack air space with insulation or other
23 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 A. Vent Termination Minimum Clearances 6 Termination Locations Fire Risk.Maintain vent clearance to combustibles as specified.• DO NOT pack air space with insulation or other materials. Failure to keep insulation or other materials away from ve...
Page 24 - MINIMUM CLEARANCES REQUIRED FOR BALANCED FLUE TERMINALS
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 24 Figure 6.3 Minimum Clearances for Termination NOTES: 1. All distances are measured vertically or horizontally along the wall to a point in line with the nearest part of the terminal. 2. Prohibited area below electricity meter or fuse box extend...
Page 25 - Vent Information and Diagrams; WARNING! Risk of Fire or Asphyxiation.; D. Measuring Standards; Effective
25 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 7 Vent Information and Diagrams Figure 7.1 A. Approved Pipe This appliance is approved for use with Hearth & Home Technologies SLP venting systems. Refer to Section 16.C for vent component information. DO NOT mix pipe, fittings or joining m...
Page 26 - Top Vent - Horizontal Termination; INSTALLED; One Elbow; Elbow only; Elbow only
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 26 Top Vent - Horizontal Termination Figure 7.3 H 2 H 1 V 1 INSTALLED HORIZONTALLY Figure 7.4 One Elbow Two Elbows V 1 H 1 V 1 Minimum H 1 + H 2 Maximum Elbow only Not Allowed 1 ft. 305 mm 2 ft. 610 mm 2 ft. 610 mm 5 ft. 1.52 m 3 ft. 914 mm 8 ft. ...
Page 27 - Three Elbows; USE SLP SERIES COMPONENTS ONLY; attached to the fireplace before a 90° elbow.
27 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 Top Vent - Horizontal Termination - (continued) Figure 7.5 Three Elbows V 1 Minimum H 1 Maximum V 2 Minimum H 2 Maximum 6 in. 152 mm 1 ft. 305 mm 1 ft. 305 mm 1 ft. 305 mm 1 ft. 305 mm 2 ft. 610 mm 2 ft. 610 mm 2 ft. 610 mm 2 ft. 610 mm 2 ft. 6...
Page 28 - Top Vent - Vertical Termination; NO OTHER FLUE SYSTEMS OR COMPONENTS; • Vertical sections 1 inches (25.4 mm) on all sides of; MODEL; Straight Up Vertical Flue System
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 28 Top Vent - Vertical Termination This model is approved to use SLP Series flue pipe com- ponents. A SLP-TVHW vertical Termination Cap must be used to terminate flue systems in a vertical position.Approved flue system components are labeled for i...
Page 29 - No Elbow; The vertical termination baffle should be used for runs of 10 ft.
29 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 Top Vent - Vertical Termination - (continued) No Elbow Figure 7.7 V 1 = 38 ft. Max. (11.58 m) V 1 = 3 ft. Min. (914 mm) VERTICAL TERMINATION BAFFLE Note: The vertical termination baffle should be used for runs of 10 ft. (3.05 m) or greater.The ...
Page 30 - Flue System Approvals And Installations; • Horizontal sections 3 in. (76 mm) from the top of the; Flue system termination kits
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 30 Figure 7.8 Flue Components and Terminations MODEL SOHO-N-AUB FLUE TERMINATION APPROVALS SLP-TRAP2 HORIZONTAL TERMINATION CAP SLP-TVHW VERTICAL TERMINATION CAP DVP-FBHT HORIZONTAL TERMINATION CAP Flue System Approvals And Installations These mod...
Page 33 - A. Pipe Clearances to Combustibles; Maintain air space clearance to; Vent Clearances and Framing; B. Wall Penetration Framing; Combustible Wall Penetration
33 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 A. Pipe Clearances to Combustibles WARNING! Risk of Fire! Maintain air space clearance to vent. DO NOT pack insulation or other combustibles: • Between ceiling firestops • Between wall shield firestops • Around vent systemFailure to keep insula...
Page 34 - C. Install the Ceiling Firestop; MUST; lation around the vent. Insulation must be kept
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 34 Figure 8.4 Installing the Attic Shield 3 FASTENERS PER SIDE INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP INSTALLED BELOW CEILING CEILING FIRESTOP INSTALLED ABOVE CEILING C. Install the Ceiling Fi...
Page 35 - D. Install Attic Insulation Shield; Flat Ceiling Installation
35 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 D. Install Attic Insulation Shield WARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home Technologies Inc. requires the use of an attic shield. An attic shield constructed of 26 gauge minimum metal that...
Page 36 - A. Securing and Leveling the Appliance; Appliance Preparation
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 36 A. Securing and Leveling the Appliance WARNING! Risk of Fire! Prevent contact with: • Sagging or loose insulation • Insulation backing or plastic • Framing and other combustible materialsBlock openings into the chase to prevent entry of blown- ...
Page 37 - Control Compartment Access Door; Removing Fixed Glass Assembly
37 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 Figure 9.2 Fixed Glass Assembly GLASS ASSEMBLY LATCHES (BOTH BOTTOM AND TOP) GLASS ASSEMBLY TAB GLASS CLIP POST B. Covers Removal For Servicing Control Compartment Access Door • Lift the lower door up and out to access the gas controls. Trim Do...
Page 38 - A. Assemble Vent Sections; WARNING! Risk of Fire or Explosion!; then rotate counterclockwise to lock
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 38 10 Installing Vent Pipe (SLP Pipe) Figure 10.2 High Temperature Silicone Sealant A. Assemble Vent Sections To attach the first vent component to the starting collars of the appliance:• Lock the vent components into place by sliding the pipe sec...
Page 39 - B. Assemble Slip Sections; Pilot hole; C. Secure the Vent Sections
39 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 Figure 10.5 Securing Vertical Pipe Sections Figure 10.6 Securing Horizontal Pipe Sections B. Assemble Slip Sections • Slide the inner flue of the slip section into the inner flue of the pipe section and the outer flue of the slip section over t...
Page 40 - D. Disassemble Vent Sections; both pipe sections are aligned as shown in Figure 10.8.; E. Install Support Brackets; For Horizontal Runs -; The flue system must be supported
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 40 D. Disassemble Vent Sections • Rotate either section (see Figure 10.7) so the seams on both pipe sections are aligned as shown in Figure 10.8. • Pull carefully to separate the pieces of pipe. Figure 10.8 Align and Disassemble Vent Sections Figu...
Page 41 - F. Install Firestops
41 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 10 in. (254 mm) 10 in. (254 mm) INTERIOR WALL SHIELD F. Install Firestops For Horizontal Runs - Firestops are REQUIRED on both sides of a combustible wall through which the flue passes.To install firestops (heat shield) for horizontal runs that...
Page 42 - the termination cap must be; For Horizontal Terminations using the SLP-TRAP; Cap Specification Chart
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 42 Figure 10.14 Venting through the Wall • The termination kit should pass through the wall firestops from the exterior of the building. • Adjust the termination cap to its final exterior position on the building and interlock the flue sections. W...
Page 43 - I. Install Metal Roof Flashing; Heat shields may not be field constructed.; H. Heat Shield Requirements for Horizontal
43 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 I. Install Metal Roof Flashing • See minimum vent heights for various pitched roofs (Figure 10.16) to determine the length of pipe to extend through the roof. • Slide the roof flashing over the pipe sections extending through the roof as shown ...
Page 44 - CAULK; J. Assemble and Install Storm Collar; Wear protective gloves and safety glasses during instal-; BRACKETS; K. Install Vertical Termination Cap; MUST BE
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 44 CAULK J. Assemble and Install Storm Collar CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. • Connect both halves of the storm collar with two screw...
Page 45 - Gas Information; A. Gas Pressure Requirements; Primary Aeration Setting
45 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 11 Gas Information A. Gas Pressure Requirements Pressure requirements for SOHO-N-AUB fireplaces are shown in below.Two taps are provided on the front of the gas valve for a test gauge connection to measure the inlet and outlet pressures.The fir...
Page 47 - Electrical Information; A. Wiring Requirements; Ignition System Wiring; WARNING! Risk of Shock or Explosion! DO NOT; C. Optional Accessories Requirements
47 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 12 Electrical Information Figure 12.1 IPI Wiring Diagram /RC300AU A. Wiring Requirements NOTICE: This appliance must be installed by a qualified electrician in accordance with the relevant national and local regulations. • Wire the appliance ju...
Page 48 - Use of the fan requires that the Junction Box (factory; if any of the original wire as
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 48 BLUE BROWN GREEN/ YELLOW BROWN GREEN/YELLOW BLUE Figure 12.2 D. Blower Use of the fan requires that the Junction Box (factory installed) be connected to 220-240 VAC service before permanently enclosing the fireplace. The access hole for connect...
Page 49 - E. Control Module Operation
49 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 Note: If the module is in LOCK-OUT mode, resetting the circuit breaker to the appliance will also reset the module. Figure 12.4 Control Module E. Control Module Operation 1. The control module has an ON/OFF/REMOTE selector switch that must be s...
Page 50 - • Read, understand and follow these instructions for safe; Introduction
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 50 Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions:• Installation and use of any damaged system component.• Modification of the system component.• Installation other than a...
Page 51 - Installation of Remote Control Housing; Changing Temperature Scale; FCC Requirements
51 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 5. Close the housing door. See Figure 12.8. 4. Place remote control inside housing. See Figure 12.7. Figure 12.7 Remote in Housing Installation of Remote Control Housing CAUTION! Risk of Fire! DO NOT install damaged or modified components . War...
Page 52 - AUX300CE Module Installation; CONTROL MODULE; FAN CORD; Programming the RC300AU to the Control Module
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 52 Figure 12.8 Mounting Remote Control Housing AUX300CE Module Installation • Insert the 4 hole harness from the AUX300CE module into the 4 pin plug on the control module. See Figure 12.9. Fan Installation • Insert the 3 prong plug from the fan in...
Page 53 - Function Buttons; For example: Flame Height will not; Idle When Remote is in ON Mode
53 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 Function Buttons Menu Select V V Use POWER button to turn the unit on and off. Use MENU button to display the menu functions. Only functions that can be activated will be displayed. For example: Flame Height will not be displayed when the remot...
Page 56 - Frequently Asked Questions/Troubleshooting; Symptom
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 56 Frequently Asked Questions/Troubleshooting Symptom Possible Cause Corrective Action Remote control will not transmit Batteries Verify batteries are functional and installed correctly. Remote control is in Child Lock mode Disengage Child Lock mo...
Page 57 - Finishing; A. Framing and Finishing Instructions; Finishing Instructions; B. Mantel Projections
57 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 13 Finishing A. Framing and Finishing Instructions WARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as specified. Framing closer than the minimums listed must be constructed entirely of noncom- bustible materials (i.e...
Page 58 - Remove shipping materials from inside or underneath the; C. Clean the Appliance; Clean/vacuum any sawdust that may have accumulated; Appliance Setup
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 58 A. Remove Fixed Glass Assembly See Section 9.B. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the firebox. C. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the firebox or un...
Page 59 - E. Log Placement Instructions
59 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 E. Log Placement Instructions Log Assembly: LOGS-SOHOCE CAUTION: Logs are fragile. Carefully remove the logs from the packaging. 2 1 Step 1. Place Log #1 (SRV2111-700) against rear right tab with its slot over center locating tab. Step 2. Place...
Page 60 - F. Install Media Rock Kit
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 60 1. Remove the front and glass from the unit and set aside. Remove the logs (if installed) from the unit and either discard or save for later use. 2. Fold down the log locating tabs (if bent up) on the base pan so they are parallel with the burn...
Page 61 - Troubleshooting; A. IntelliFire PlusTM Ignition System
61 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 15 Troubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualified service technician in the ...
Page 63 - Reference Materials; A. Appliance Dimension Diagram
63 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 16 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5. Figure 16.1 Appliance Dimensions Location Inches Millimeter Loca...
Page 64 - B. Maintenance Tasks; Inspect
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 64 B. Maintenance Tasks Inspect Maintenance Tasks Doors 1. Inspect for scratches, dents or other damage and repair as necessary.2. Verify no obstructions to airflow.3. Verify maintenance of proper clearance to combustible household objects. Gasket...
Page 65 - Horizontal Pipe; C. Vent Components Diagrams
65 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 Effective Height/ Length SLP-PIPE SLP-HVS Horizontal Pipe Support SLP-FS Ceiling Firestop SLP-WS Wall Shield Firestop Figure 16.2 SLP Series Vent Components C. Vent Components Diagrams 8-3/4 in. 222 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm SLP45 45...
Page 66 - B. Vent Components Diagrams; Cap Shield
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 66 SLK-SNKD Snorkel Termination Cap SLP-TVHW Vertical Termination Cap SLP-CCS-BK Cathedral Ceiling Support Box-Black SLP-DCF-BK Ceiling Firestop Black SLP-WT-BK Wall Thimble-Black B. Vent Components Diagrams (continued) Cap Shield DRC-RADIUS 13-7/...
Page 67 - HORIZONTAL TERMINATION CAP
67 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 SLP-HRC-SS SLP-HRC-ZC-SS HORIZONTAL TERMINATION CAP B. Vent Components Diagrams (continued) Figure 16.4 SLP Series Vent Components SLP90 SL-2DVP DVP-FBHT DVP-FBHT 7 in. (178 mm) 15-1/2 in. (394 mm) 12 in. (305 mm) SLP-TRAP Horizontal Terminatio...
Page 68 - Beginning Manufacturing Date: March 2011; Log Set Assembly; ITEM
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 68 D. Service Parts Beginning Manufacturing Date: March 2011 Ending Manufacturing Date: ______ SOHO-N-AUB 1 2 3 Log Set Assembly IMPORTANT; THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide m...
Page 69 - Service Parts
69 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 SOHO-N-AUB IMPORTANT; THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer. ITEM PART ...
Page 70 - Rock Media Option
Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 70 Service Parts SOHO-N-AUB IMPORTANT; THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized deal...
Page 71 - E. Contact Information; For the location of your nearest Heat & Glo dealer,; DO NOT DISCARD THIS MANUAL; NOTICE
71 Heat & Glo • SOHO-N-AUB • 2197-980 Rev. F • 5/12 E. Contact Information Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer, please visit www.heatnglo.com. - NOTES - __________________________________________________...