Hand Held Products IT5800 - Manuals
Hand Held Products IT5800 – Manual in PDF format online.
Manuals:
Manual Hand Held Products IT5800
Summary
Disclaimer Hand Held Products (“Hand Held Products”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult Hand Held Products to determine whether any such changes have been made. The inf...
Statement of Agency Compliance This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired oper...
Mexico Patents Please refer to the IT5600/5800 packaging for patent information. Solids and Water Protection The IT5600 has a rating of IP41, immunity of foreign particles and dripping water. The IT5800 has a rating of IP54, immunity of windblown dust penetration and splashing water. Certified
i Chapter 1 - Getting Started IT5600/5800 ......................................................................... 1-1About This Manual ............................................................... 1-1Unpacking the Scanner ......................................................... 1-1IT5600 Models...
ii Connecting the Scanner with RS-232 Serial Port ................ 2-8 RS-232 Baud Rate .......................................................... 2-9RS-232 Word Length: Data Bits, Stop Bits, and Parity 2-10RS-232 Handshaking ................................................... 2-11Wand Emulation Con...
iii Output Sequence Overview ................................................ 3-10 Output Sequence Editor................................................ 3-11Require Output Sequence ............................................. 3-11 Multiple Symbols .....................................................
iv Secondary Code 39 Wand Emulation ................................... 6-2Secondary Laser Emulation .................................................. 6-3Laser Emulation Transmission Rate ..................................... 6-3Laser Emulation Polarity ................................................
vii Chapter 11 - Serial Programming Commands Conventions ........................................................................ 11-1Menu Command Syntax ..................................................... 11-1 Query Commands ......................................................... 11-2Concatenat...
viii Appendix A - Appendix A Symbology Chart ..................................................................A-1ASCII Conversion Chart (Code Page 1252).........................A-2Code Page Mapping of Printed Bar Codes ...........................A-4
IT5600/IT5800 User’s Guide 1 - 1 1 Getting Started IT5600/5800 The IT5600 and IT5800 mark a new performance level for handheld scanners. Both the IT5600 and IT5800 are powered by Hand Held Products Adaptus TM Imaging Technology. The performance of Adaptus technology delivers aggressive read rates an...
1 - 4 IT5600/IT5800 User’s Guide IT5800 Scanner (with aimer beam option) Identification
1 - 6 IT5600/IT5800 User’s Guide Reading Techniques The scanner has a view finder that projects a bright red aiming beam that corresponds to its horizontal field of view. The aiming line should be centered horizontally over the bar code; it will not read if the aiming line is in any other direction....
IT5600/IT5800 User’s Guide 1 - 7 Note: After you scan one of the codes, power cycle the host terminal to have the interface in effect. Keyboard Wedge Connection IT5600 scanners are factory programmed for a keyboard wedge interface to an IBM PC AT with a USA keyboard. If this is your interface and yo...
1 - 8 IT5600/IT5800 User’s Guide Wand Emulation Plug & Play In Wand Emulation mode, the imager decodes the bar code then sends data in the same format as a wand imager. The Code 39 Format converts all symbologies to Code 39. The Same Code Format transmits UPC, EAN, Code 128 and Interleaved 2 of ...
1 - 10 IT5600/IT5800 User’s Guide Connecting the Scanner with USB A scanner can be connected to the USB port of a computer. 1. Connect the appropriate interface cable to the scanner and to the computer. 2. The scanner beeps. 3. Verify the scanner operation by scanning a bar code from the Sample Symb...
1 - 12 IT5600/IT5800 User’s Guide USB Com Port Emulation Scan the following code to program the IT5600/5800 to emulate a regular RS-232-based Com Port. If you are using a Microsoft® Windows® PC, you will need to download a driver from the Hand Held Products website ( www.handheld.com ) . The driver ...
IT5600/IT5800 User’s Guide 2 - 1 2 Terminal Interfaces Terminal ID If your interface is not a standard PC AT, refer to "Supported Terminals" on page 2-2 through page 2-3 , and locate the Terminal ID number for your PC. Scan the Terminal ID bar code below, then scan the numeric bar code(s) fr...
2 - 2 IT5600/IT5800 User’s Guide Supported Terminals Terminal Model(s) Terminal ID DEC VT510, 520, 525 (PC style) 005 DEC VT510, 520, 525 (DEC style LK411) 104 Esprit 200, 400 005 Heath Zenith PC, AT 003 HP Vectra 003 IBM XT 001 IBM PS/2 25, 30, 77DX2 002 IBM AT, PS/2 30–286, 50, 55SX, 60, 70, 70–06...
2 - 4 IT5600/IT5800 User’s Guide Keyboard Country Scan the appropriate country code below to program the keyboard for your country. As a general rule, the following characters are supported, but need special care for countries other than the United States:@ | $ # { } [ ] = / ‘ \ < > ~ * United...
IT5600/IT5800 User’s Guide 2 - 5 Please refer to Hand Held Products website ( www.handheld.com ) for complete keyboard country support information and applicable interfaces. If you need to program a keyboard for a country other than one listed above, scan the Program Keyboard Country bar code below,...
2 - 6 IT5600/IT5800 User’s Guide Emulate External Keyboard should be scanned if you do not have an external keyboard (IBM AT or equivalent). Note: After scanning the Emulate External Keyboard bar code, you must power cycle your computer. Keyboard Modifiers This modifies special keyboard features, su...
IT5600/IT5800 User’s Guide 2 - 7 Automatic Direct Connect Mode: This selection can be used if you have an IBM AT style terminal and the system is dropping characters. Default = Off Automatic Direct Connect Mode On * Automatic Direct Connect Mode Off
2 - 10 IT5600/IT5800 User’s Guide RS-232 Word Length: Data Bits, Stop Bits, and Parity Data Bits sets the word length at 7 or 8 bits of data per character. If an application requires only ASCII Hex characters 0 through 7F decimal (text, digits, and punctuation), select 7 data bits. For applications ...
IT5600/IT5800 User’s Guide 2 - 11 RS-232 Handshaking RS-232 handshaking is a set of rules concerning the exchange of data between serially communicating devices. Default = RTS/CTS, XON/XOFF and ACK/ NAK Off Wand Emulation Connection The Wand Emulation Connection bar codes should be used if you want ...
IT5600/IT5800 User’s Guide 2 - 13 Wand Emulation Idle The idle describes the state of the scanner when no data is being transmitted. When in Wand Emulation mode, you must set the scanner’s idle state to match the idle state for the device to which the scanner is connected. Default = Idle High . Wand...
2 - 14 IT5600/IT5800 User’s Guide Delay Between Blocks Note: This option is not applicable to Laser Emulation Raw Output (see Secondary Laser Emulation on page 6-3). This sets the delay time between data blocks. Default = 50ms. Overall Checksum Note: This option is not applicable to Laser Emulation ...
IT5600/IT5800 User’s Guide 3 - 1 3 Output Good Read Indicators Beeper – Good Read The beeper may be programmed On or Off in response to a good read. Turning this option off, only turns off the beeper response to a good read indication. All error and menu beeps are still audible. Default = On. Beeper...
IT5600/IT5800 User’s Guide 3 - 3 Good Read Delay This sets the minimum amount of time before the scanner can read another bar code. Default = No Delay. User-Specified Good Read Delay If you want to set your own length for the good read delay, scan the bar code below, then set the delay (from 0-30,00...
3 - 4 IT5600/IT5800 User’s Guide Read Time-Out Use this selection to set a time-out (in milliseconds) of the scanner’s trigger when using serial commands to trigger the scanner. Once the scanner has timed out, you can activate the scanner either by pressing the trigger or using a serial trigger comm...
IT5600/IT5800 User’s Guide 3 - 5 Presentation Mode Note: Presentation mode does not work when a scanner is programmed for the laser emulation interface. Note: If the Presentation Mode selection is enabled, the aimer beam option is disabled. The LEDs are off until a bar code is presented to the scann...
IT5600/IT5800 User’s Guide 3 - 7 Aimer Beam Delay (Aimer Beam option only) The Aimer Beam Delay allows a delay time for the operator to aim the reader before the standard illumination and decoding starts. The quickset codes sets the time between when the trigger is pulled and when the decode starts ...
3 - 8 IT5600/IT5800 User’s Guide Aimer Beam Time-Out (Aimer Beam option only) Aimer Beam Time-Out powers down the aimer beam after a time-out if the trigger is still pulled and there isn’t a valid decode. Scan the bar code below, then set the time-out by scanning digits (from 0 - 240,000 ms) from th...
3 - 10 IT5600/IT5800 User’s Guide Output Sequence Overview Require Output Sequence When turned off, the bar code data will be output to the host as the scanner decodes it. When turned on, all output data must conform to an edited sequence or the scanner will not transmit the output data to the host ...
IT5600/IT5800 User’s Guide 3 - 11 Output Sequence Editor Require Output Sequence When an output sequence is Required , all output data must conform to an edited sequence or the scanner will not transmit the output data to the host device. When it’s On/Not Required , the scanner will attempt to get t...
IT5600/IT5800 User’s Guide 3 - 13 The breakdown of the command line is shown below: SEQBLK sequence editor start command62 code identifier for Code 39 0011 Code 39 code length (9) plus CR suffix (2) = 11 41 start character match for Code 39, 41h = “A” FF termination string for first code 6A code ide...
3 - 14 IT5600/IT5800 User’s Guide If you want a different notation than “NR,” for example, “Error,” or “Bad Code,” you can edit the output message using the Data Formatter (page 5-5). The hex code for the No Read symbol is 9C. Video Reverse Video Reverse is used to allow the scanner to read bar code...
IT5600/IT5800 User’s Guide 4 - 1 4 Data Editing Prefix/Suffix Overview When a bar code is scanned, additional information is sent to the host computer along with the bar code data. This group of bar code data and additional, user-defined data is called a “message string.” The selections in this sect...
4 - 2 IT5600/IT5800 User’s Guide To Add a Prefix or Suffix: Step 1. Scan the Add Prefix or Add Suffix symbol ( page 4-3 ). Step 2. Determine the 2 digit Hex value from the Symbology Chart (included in the Appendix A ) for the symbology to which you want to apply the prefix or suffix. For example, fo...
IT5600/IT5800 User’s Guide 4 - 3 To Clear One or All Prefixes or Suffixes: You can clear a single prefix or suffix, or clear all prefixes/suffixes for a symbology. When you Clear One Prefix (Suffix), the specific character you select is deleted from the symbology you want. When you Clear All Prefixe...
4 - 4 IT5600/IT5800 User’s Guide Suffix Selections Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function code to the terminal. Charts of these function codes are provided in Supported Interface Keys starting...
IT5600/IT5800 User’s Guide 4 - 5 Intercharacter Delay An intercharacter delay of up to 495 milliseconds may be placed between the transmission of each character of scanned data. Scan the Intercharacter Delay bar code below, then scan the number of milliseconds and the SAVE bar code using the Program...
4 - 6 IT5600/IT5800 User’s Guide Interfunction Delay An interfunction delay of up to 495 milliseconds may be placed between the transmission of each segment of the message string. Scan the Interfunction Delay bar code below, then scan the number of milliseconds and the SAVE bar code using the Progra...
IT5600/IT5800 User’s Guide 5 - 1 5 Data Formatting Data Format Editor Introduction You may use the Data Format Editor to change the scanner’s output. For example, you can use the Data Format Editor to insert characters at certain points in bar code data as it is scanned. The selections in the follow...
5 - 2 IT5600/IT5800 User’s Guide inside back cover to program the scanner for your terminal ID (you must enter 3 digits). For example, scan 0 0 3 for an AT wedge. Note: The wildcard for all terminal types is 099. Step 4. Code I.D. In the Appendix A , find the symbology to which you want to apply the...
IT5600/IT5800 User’s Guide 5 - 3 (00-99) for the number of characters and xx stands for the hex value for an ASCII code. See ASCII Conversion Chart (Code Page 1252) on page A-2.) F3 Send up to but not including “ss” character (Search and Send) starting from current cursor position, leaving cursor po...
5 - 4 IT5600/IT5800 User’s Guide zz is the list of characters to be suppressed. (xx stands for the hex value for an ASCII code, see ASCII Conversion Chart (Code Page 1252) on page A- 2.) FC Disables suppress filter and clear all suppressed characters. Syntax = FC. E4 Replaces up to 15 characters in ...
IT5600/IT5800 User’s Guide 6 - 1 6 Secondary Interface By switching secondary interface cables, the IT5600/5800 scanner, for example, can communicate with a portable data terminal (secondary interface) in addition to the host terminal (primary interface). See the tables below for the secondary inter...
6 - 2 IT5600/IT5800 User’s Guide You can temporarily disable the secondary interface, but still retain the secondary interface settings in the imager’s memory by scanning the Disable bar code below. To re-enable the secondary interface, scan the Enable bar code. Default =Disable . Secondary RS-232 C...
IT5600/IT5800 User’s Guide 7 - 1 7 Symbologies Introduction This programming section contains the following menu selections. Refer to Chapter 11 for settings and defaults. All Symbologies If you want to decode all the symbologies allowable for your scanner, scan the All Symbologies On code. If on th...
7 - 2 IT5600/IT5800 User’s Guide Message Length You are able to set the valid reading length of some of the bar code symbologies. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will issue an error beep. You may wish to set the same value for minimum an...
IT5600/IT5800 User’s Guide 7 - 3 Codabar <Default All Codabar Settings> Codabar Codabar Start / Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit . Codabar Check...
7 - 4 IT5600/IT5800 User’s Guide When Check Character is set to Validate, but Don’t Transmit , the unit will only read Codabar bar codes printed with a check character, but will not transmit the check character with the scanned data. Codabar Concatenation Codabar supports symbol concatenation. When ...
IT5600/IT5800 User’s Guide 7 - 5 Codabar Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 7-2 for additional information. Minimum and Maximum lengths = 2-60. Minimum Default = 4, Maximum Default = 60. Code 39 < Default All Code 39 Settings >...
IT5600/IT5800 User’s Guide 7 - 7 Code 39, continued Code 39 Append This function allows the scanner to append the data from several Code 39 bar codes together before transmitting them to the host computer. When this function is enabled, the scanner stores those Code 39 bar codes that start with a sp...
7 - 8 IT5600/IT5800 User’s Guide Note: Trioptic Code must be turned off to scan Code 32 Pharmaceutical codes. Full ASCII If Full ASCII Code 39 decoding is enabled, certain character pairs within the bar code symbol will be interpreted as a single character. For example: $V will be decoded as the ASC...
IT5600/IT5800 User’s Guide 7 - 9 Code 39 Code Page Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is different from the one the host prog...
7 - 10 IT5600/IT5800 User’s Guide When Check Digit is set to Validate, but Don’t Transmit, the unit only reads Interleaved 2 of 5 bar codes printed with a check digit, but will not transmit the check digit with the scanned data. When Check Digit is set to Validate and Transmit, the scanner only read...
IT5600/IT5800 User’s Guide 7 - 11 Code 93 < Default All Code 93 Settings > Code 93 Code 93 Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 7-2 for additional information. Minimum and Maximum lengths = 0-80. Minimum Default = 0, Maximum Defa...
7 - 12 IT5600/IT5800 User’s Guide Code 2 of 5 <Default All Code 2 of 5 Settings> Code 2 of 5 Code 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 7-2 for additional information. Minimum and Maximum lengths = 1-48. Minimum Default = 4...
IT5600/IT5800 User’s Guide 7 - 13 IATA Code 2 of 5, continued IATA Code 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 7-2 for additional information. Minimum and Maximum lengths = 1-48. Minimum Default = 4, Maximum Default = 48. Matrix 2...
7 - 14 IT5600/IT5800 User’s Guide Matrix 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 7-2 for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80. Code 11 <Default All Code 11 Setting...
IT5600/IT5800 User’s Guide 7 - 15 Code 11, continued Code 11 Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 7-2 for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80. Code 128 <Default All C...
IT5600/IT5800 User’s Guide 7 - 17 Code 128 Function Code Transmit By default, Code 128 function codes are not transmitted with Code 128 bar code data. However, if you wish to transmit Code 128 function codes with the bar code data, scan the Function Codes On bar code, below. Telepen <Default All ...
7 - 18 IT5600/IT5800 User’s Guide Telepen Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 7-2 for additional information. Minimum and Maximum lengths = 1-60. Minimum Default = 1, Maximum Default = 60. UPC A <Default All UPC A Settings> UPC ...
7 - 20 IT5600/IT5800 User’s Guide UPC A, continued UPC A Addenda This selection adds 2 or 5 digits to the end of all scanned UPC A data. Default = Off for both 2 Digit and 5 Digit Addenda. UPC A Addenda Required When Addenda Required is set to on, the scanner will only read UPC A bar codes that have...
7 - 22 IT5600/IT5800 User’s Guide UPC E, continued UPC E0 and UPC E1 Expand UPC E Expand expands the UPC E code to the 12 digit, UPC A format. Default = Off. UPC E0 and UPC E1 Addenda Required When Addenda Required is set to on, the scanner will only read UPC E bar codes that have addenda. Default =...
7 - 24 IT5600/IT5800 User’s Guide EAN/JAN 13 <Default All EAN/JAN Settings> EAN/JAN 13 EAN/JAN 13 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. EAN/JAN 13 Addenda This selection adds 2 or 5 di...
IT5600/IT5800 User’s Guide 7 - 25 EAN/JAN 13, continued EAN/JAN 13 Addenda Required When Addenda Required is set to on, the scanner will only read EAN/JAN 13 bar codes that have addenda. Default = Not Required. EAN/JAN 13 Addenda Separator When this feature is on, there is a space between the data f...
7 - 26 IT5600/IT5800 User’s Guide EAN/JAN 8 <Default All EAN/JAN 8 Settings> EAN/JAN 8 EAN/JAN 8 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. EAN/JAN 8 Addenda This selection adds 2 or 5 digi...
IT5600/IT5800 User’s Guide 7 - 27 EAN/JAN 8, continued EAN/JAN 8 Addenda Required When Addenda Required is set to on, the scanner will only read EAN/JAN 8 bar codes that have addenda. Default = Not Required. EAN/JAN 8 Addenda Separator When this feature is on, there is a space between the data from ...
7 - 28 IT5600/IT5800 User’s Guide MSI, continued MSI Check Character Different types of check characters are used with MSI bar codes. You can program the scanner to read MSI bar codes with Type 10 check characters. Default = Validate Type 10, but Don’t Transmit. When Check Character is set to Valida...
IT5600/IT5800 User’s Guide 7 - 29 Plessey Code <Default All Plessey Code Settings> Plessey Code Plessey Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 7-2 for additional information. Minimum and Maximum lengths = 4-48. Minimum Default = 4,...
IT5600/IT5800 User’s Guide 7 - 31 RSS Expanded, continued RSS Expanded RSS Expanded Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 7-2 for additional information. Minimum and Maximum lengths = 4-74. Minimum Default = 4, Maximum Default = 74. EAN...
IT5600/IT5800 User’s Guide 7 - 33 Korea Post Code <Default All Korea Post Code Settings> Korea Post Code Korea Post Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 7-2 for additional information. Minimum and Maximum lengths = 2-80. Minimum ...
7 - 34 IT5600/IT5800 User’s Guide PosiCode <Default All PosiCode Settings> PosiCode A and B You have to have PosiCode A and B on to read any of the PosiCode symbologies. PosiCode Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 7-2 for addit...
IT5600/IT5800 User’s Guide 7 - 35 Trioptic Code Trioptic Code is used for labeling magnetic storage media. Note: If you are going to scan Code 32 Pharmaceutical codes, Trioptic Code must be off. Codablock F <Default All Codablock F Settings> Codablock F Codablock F Message Length Scan the bar ...
7 - 36 IT5600/IT5800 User’s Guide Code 16K <Default All Code 16K Settings> Code 16K Code 16K Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 7-2 for additional information. Minimum and Maximum lengths = 0-160. Minimum Default = 1, Maximum D...
IT5600/IT5800 User’s Guide 7 - 37 Code 49 Code 49 Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 7-2 for additional information. Minimum and Maximum lengths = 1-81. Minimum Default = 1, Maximum Default = 81. * On Off Minimum Message Length Maxim...
IT5600/IT5800 User’s Guide 8 - 1 8 Interface Keys Keyboard Function Relationships The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII “CTRL”+ relationships apply to all terminals that can be used with the scanner. Refer to page 2-6 enable Control + ASCII mode. Function Code HEX/ASC...
IT5600/IT5800 User’s Guide 9 - 1 9 Utilities To Add a Test Code I.D. Prefix to All Symbologies This selection allows you to turn on transmission of a Code I.D. before the decoded symbology. (See the Symbology Chart, included in the Appendix A , page A-1) for the single character code that identifies...
9 - 2 IT5600/IT5800 User’s Guide Temporary Visual Menu 2003 Configuration For quick download communication configuration, scan the Visual Menu 2003 bar code to temporarily configure the scanner for Visual Menu 2003 settings. Refer to Visual Menu 2003 on page 10-1 for additional information about Vis...
IT5600/IT5800 User’s Guide 10 - 1 10 Visual Menu 2003 Visual Menu 2003 Introduction Visual Menu 2003 provides the ability to configure a scanning device by connecting the scanner to the com port of a PC. Visual Menu 2003 allows you to download updates to a scanner’s firmware, change programmed param...
IT5600/IT5800 User’s Guide 11 - 1 11 Serial Programming Commands The serial programming commands can be used in place of the programming bar codes. Both the serial commands and the programming bar codes will program the IT5600/5800. For complete descriptions and examples of each serial programming c...
11 - 2 IT5600/IT5800 User’s Guide Query Commands Several special characters can be used to query the device about its settings. ^ What is the default value for the setting(s). ? What is the device’s current value for the setting(s). * What is the range of possible values for the setting(s). (The de-...
IT5600/IT5800 User’s Guide 11 - 3 When responding, the device echoes back the command sequence with the status character inserted directly before each of the punctuation marks (the period, exclamation point, comma, or semicolon) in the command. Examples of Query Commands In the following examples, a...
11 - 4 IT5600/IT5800 User’s Guide Trigger Commands You can activate and deactivate the scanner with serial trigger commands. First, the scanner must be put in Manual/Serial Trigger Mode either by scanning the Manual/Serial Trigger Mode bar code ( page 3-3 ), or by sending the Manual/ Serial Menu Com...
IT5600/IT5800 User’s Guide 11 - 7 Wand Emulation Transmis-sion Rate 10 WNDSPD0 2-12 *25 WNDSPD1 2-12 40 WNDSPD2 2-12 80 WNDSPD3 2-12 120 WNDSPD4 2-12 150 WNDSPD5 2-12 200 WNDSPD6 2-12 Wand Emulation Polarity *Black High WNDPOL0 2-12 White High WNDPOL1 2-12 Wand Emulation Idle Idle Low WNDIDL0 2-13 *...
IT5600/IT5800 User’s Guide 11 - 9 Aimer Beam Time-Out Time-Out Duration (0 - 240,000 ms) *0 SCNADR###### 3-8 Centering Centering On DECWIN1 3-8 *Centering Off DECWIN0 3-8 Left of Centering Window *40 DECLFT### 3-8 Right of Centering Window *60 DECRGT### 3-8 Output Sequence Editor Enter Sequence SEQB...
IT5600/IT5800 User’s Guide 12 - 1 12 Product Specifications IT5600 Product Specifications Parameter Specification Dimensions (Typical): Height 6.2 inches (15.7 cm) Length 5.3 inches (13.5 cm) Width 3.2 inches (8.1 cm) Weight 6.5 ounces (185 g) Light Source 630 nM visible red LED Scan Rate 270 scans ...
IT5600/IT5800 User’s Guide 12 - 3 IT5800 Product Specifications Parameter Specification Dimensions (Typical): without aimer with aimer Height 6.4 inches (16.3 cm) 6.5 inches (16.5 cm) Length 5.3 inches (13.5 cm) 5.3 inches (13.5 cm) Width 3.2 inches (8.1 cm) 3.2 inches (8.1 cm) Weight 7.5 ounces (21...
IT5600/IT5800 User’s Guide 12 - 5 Standard Cable Pinouts Laser Output Only (Laser Compatible Bar Image) 10 Pin Modular Plug connects to the scanner handle 1 T urn on good read or LED beeper 2 T rigger signal to decoder 3 L aser enable 4 S upply ground 5 6 D igital bar code data output 7 S upply inpu...
12 - 6 IT5600/IT5800 User’s Guide Standard Cable Pinouts Keyboard Wedge 10 Pin RJ41 Modular Plug connects to the scanner handle 1 2 C ord shield 3 T ied to supply power 4 S upply ground 5 T erminal clock 6 T erminal data 7 S upply power input (Refer to tables on page 12-1 and page 12-3 ) 8 K eyboard...
12 - 8 IT5600/IT5800 User’s Guide Standard Cable Pinouts Serial Output 10 Pin RJ41 Modular Plug connects to the scanner handle 1 2 C ord shield 3 P rog 1 (Tied to supply power for primary cable) 4 S upply ground 5 R eceive data - Serial data to scanner 6 T ransmit data - Serial data from scanner 7 S...
IT5600/IT5800 User’s Guide 12 - 9 Standard Cable Pinouts USB 10 Pin Modular Plug connects to the scanner handle 1 2 D ata + 3 T ied to supply power 4 S upply ground 5 6 7 5 volt supply power input 8 9 10 Data -
IT5600/IT5800 User’s Guide 13 - 1 13 Maintenance Repairs Repairs and/or upgrades are not to be performed on this product. These services are to be performed only by an authorized service center. Please see Customer Support on page 14-1 for further information. Maintenance The IT5600/5800 provides re...
IT5600/IT5800 User’s Guide 13 - 3 To Replace the IT5800 Interface Cable: 1. Turn the power to the host system OFF. 2. Disconnect the imager’s cable from the terminal or computer. 3. Use a screwdriver to unscrew the cord lock from the base of the imager if in use. 4. Locate the small hole on the side...
IT5600/IT5800 User’s Guide 14 - 1 14 Customer Support Product Service and Repair Hand Held Products provides service for all its products through service centers throughout the world. To obtain warranty or non-warranty service, return the unit to Hand Held Products (postage paid) with a copy of the ...
14 - 2 IT5600/IT5800 User’s Guide Online Product Service and Repair Assistance You can also access product service and repair assistance online at www.handheld.com . Technical Assistance If you need assistance installing or troubleshooting your scanner, please call your Distributor or the nearest Ha...
IT5600/IT5800 User’s Guide A - 1 Appendix A Symbology Chart Note: “m” represents the AIM modifier character. Refer to International Technical Specification, Symbology Identifiers, for AIM modifier character details. Note: Prefix / Suffix entries for specific symbologies override the universal (All S...
A - 2 IT5600/IT5800 User’s Guide ASCII Conversion Chart (Code Page 1252 ) Note: This table applies to U.S. style keyboards. Certain characters may differ depending on your Country Code/PC regional settings. Dec Hex Char Dec Hex Char Dec Hex Char Dec Hex Char 0 00 NUL 32 20 64 40 @ 96 60 ‘ 1 01 SOH 3...
A - 4 IT5600/IT5800 User’s Guide Code Page Mapping of Printed Bar Codes Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is different from ...
Sample Symbols UPC A 0 123456 7890 Interleaved 2 of 5 Code 128 EAN 13 1234567890 Code 128 9 780330 290951 654 EAN 8 3210 5 456123 8 0 UPC-E
Hand Held Products Manuals
-
Hand Held Products 7400
Manual
-
Hand Held Products 5620
Manual
-
Hand Held Products 5770
Manual
-
Hand Held Products 7900
Manual
-
Hand Held Products Dolphin 7450
Manual
-
Hand Held Products Dolphin 7400
Manual
-
Hand Held Products 3875
Manual
-
Hand Held Products 2070
Manual
-
Hand Held Products 3220
Manual
- Hand Held Products 7400/7450 Manual
-
Hand Held Products 2020
Manual
-
Hand Held Products 3800gPDF
Manual
-
Hand Held Products 4X00 Series
Manual
- Hand Held Products 4410, 4710 Manual
-
Hand Held Products 5700
Manual
-
Hand Held Products 3800
Manual
-
Hand Held Products 3800ESD
Manual
-
Hand Held Products X5
Manual
- Hand Held Products 4410 Manual
-
Hand Held Products 3080
Manual