Page 2 - Contents
Contents Cautions ........................................................................................... Part name of the unit........................................................................ Maintenance........................................................................................
Page 3 - Cautions; Disposal of the old air conditioner; Safety Instructions and Warnings
Cautions 1 Disposal of the old air conditioner Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, wh...
Page 4 - The requirement of the connecting cable:; Specifications; The machine is adaptive in following
4. The wiring method should be in line with thelocal wiring standard.5. The power cable and connecting cable areself-provided. The requirement of the powercable: H05RN-F 3G 1.5mm 2 The requirement of the connecting cable: All the cables shall have got the Europeanauthentication certificate.6. The br...
Page 5 - Safety cautions
3 WARNING! Carefully read the following information in order to operate the airconditioner correctly. Below are listed three kinds of Safety Cautions and Suggestions. WARNING! CAUTION! Incorrect operations may result in injuries or machine damages; in some cases maycause serious consequences. Incorr...
Page 6 - Otherwise will be shocked.
4 CAUTIONS! Conditioner should not be used for any otherpurpose other than airconditioning. Don't use air-conditioner for any other specialpurposes, e.g. the preservation and protectionof food, animals, plants,pecision apparatus as wellas work of art, otherwisethe qualities of thesestuffs may be dam...
Page 7 - be sure of the following conditions.; Please call dealer to install the air-conditioner.; Incorrect pipe use may cause water leaking.; Installation
5 WARNING ! CAUTION ! Please ask the dealer or specialist to install, never try by the users themselves. After the installation please be sure of the following conditions. Incorrect installation may cause water leaking, shock and fire hazard. Please call dealer to install the air-conditioner. Air-co...
Page 8 - Introduction to Spare Parts
Introduction to Spare Parts 6 Drain Hose Swing fender Refrigerant pipe Cable line Earthing line Air filter Outlet Suction grill (located in the suction grill) In cooling operation, to discharge the water from inside the room. Discharge unit (built in) (located in the outlet) Anti-bacteria filter Air...
Page 9 - Maintenance; NOTE
7 3. Dismantle air filter CAUTION! 4. Clean 6. Close inlet grill (A) Remove dust with vacuum filter. 5. Install air filter (1) Put filter into protruding parts at the top of the inlet grill.(2) Connect the two pothooks with inlet grill See 2 [Clean inlet grill] 1. Open inlet grill See 1. Connect the...
Page 10 - Take of inlet grill; Dismantle and install swing; Install swing plate; Take off airfilter
8 3. Take of inlet grill 4. Clean CAUTION! NOTE When the filter too much dust To spray the special detergent for vent fan orutensils. 5. Install inlet grill6. Install air filter7. Close inlet grill [Clean outlet and shell] see 3see "Clean air filter"see 1 CAUTION! Don't use gasoline, benzene...
Page 11 - Seasonal Reserve
9 NOTE The inner part of indoor unit must be cleaned. Consult dealer, because clean must be done bytechnician.In cooling operation, discharging system discharge water in room. 2. 1. Seasonal Reserve Operate the unit with FAN mode on a fair day for about half a day to dry the inside of the unit well....
Page 12 - The followings are not malfuncition; Trouble Shooting
10 The followings are not malfuncition Hua Hua Trouble Shooting Water flowing sound is heard When the air conditoner is started, when the compressor starts or stops during operation or when the air conditioner is stopped,it som- etimes sounds Bi- Bi- or Godo-Godo. It is the flowing sound of the...
Page 14 - When Trouble Happens; Insufficient cooling or heating
12 When Trouble Happens Insufficient cooling or heating The operation controller adjusted as required Air filter too dirty ? Horizontal swing louver upward ? (in HEAT mode) Any obstacle exists at the air inlet or outlet? Door or window left opened ? Insufficient cooling Any other heat sources in the...
Page 15 - Indoor unit malfunction display code; Please keep this manual carefully and safely.; Outdoor unit malfunction display code
13 When Trouble Happens 1. Error display Indoor unit malfunction display code Please keep this manual carefully and safely. Outdoor unit malfunction display code When the wire remote controller display E1,Can check the outdoor unit control board LED1 or outdoor unit malfunction display code to sure ...
Page 16 - Using Directions
14 Customer Need-to-know Customer Need-to-know Please install the air conditioner according to the requirements specified in this manual to ensure the air conditioner work well. Be careful not to scratch the surface of the case during moving the air conditioner. Please keep the installation manual f...
Page 17 - Accessory parts; Installation Procedure
15 A B C D E F Installation tools Standard accessories 1. Screw driver2. Hacksaw3. Drill with a diameter of 60mm4. Inner hexagon spanner,shifting spanner5. Spanner (14, 17, 19,24,27mm)6. Pipe cutter7. Pipe expander8. Knife9. Pincers10. Leakage detector or soapy water11. Band tape12. Scraper13. Refri...
Page 18 - Meanings of Warning and Cautions:; Cautions for the installation personnel
16 Unit shall be grounded. But grounding shall not be connected to gas pipe water pipe, telephone line. Poor grounding will cause electric shock. Be sure to install a leakage breaker to avoid electric shock. Arrange water drainage according to this Manual. Cover pipe with insulation materials in cas...
Page 19 - Installation space; BEFORE INSTALLATION
(2) Ceiling height Indoor unit can be installed on ceiling of 2.5-3m in height. (Refer to Field setting and Installation Manual of ornament panel.) (3) Install suspending bolt. Check if the installation place is strong enough to hold weight. Take necessary measures in case it is not safe. (Distance ...
Page 20 - PREPARATION FOR THE INSTALLATION
3. PREPARATION FOR THE INSTALLATION (1) Position of ceiling opening between unit and suspending bolt. 3 18 AB424FCAHA AB484FCAHA (2) Cut an opening in ceiling for installation if necessary. (when ceiling already exists.) (3) Install a suspending bolt. (Use a M10 bolt) To support the unit weight, anc...
Page 21 - INSTALLATION OF INDOOR UNIT; Insert; Level
19 4. INSTALLATION OF INDOOR UNIT In the case of new ceiling < After installation on the ceiling > (3) Adjust unit to its right position. (Refer to preparation for the installation-(1)) (4) Check unit's horizontal level. Water pump and flating switch is installed inside indoor unit, check four...
Page 23 - INSTALLING THE DECORATED BOARD ON THE BODY OF INDOOR UNIT; Installation Procedures
7. INSTALLING THE DECORATED BOARD ON THE BODY OF INDOOR UNIT 6 7 21 4 2 2 1 3 As shown in Fig. 1, make the wind deflector motor of the decorated board face to the orifice of the indoorunit, and then mount the decorated board onto the body of the indoor unit. Mounting the decorated board:a. Hang temp...
Page 24 - Wiring of Decorated Board; side of indoor unit; Attention
22 Wiring of Decorated Board a. Connect it to the connector of the wind deflector motor lead on the decorated board (Fig. 5); b. Connect it to the receiving terminal of remote control on the decorated board. side of decorated board side of indoor unit electrical cabinet AB184~484FCAHA <circuit di...
Page 25 - Mounting Air Inlet Grid and Angle Covers
23 Mounting Air Inlet Grid and Angle Covers (1) Mounting the air inlet grid: Take care not to wind the lead of the wind deflector motor during mounting the air inlet grid. (2)For Model AB184-484FCAHA units, the angle covers should be mounted on the angles. ¢ Tie the thread of the angle cover onto th...
Page 28 - Electrical Wiring; lead to burning or fire accidents.; Warning; Supply Wiring Drawing
AB094FAAHAAB124FAAHAAB184FAAHAAB244FAAHAAB424FAAHAAB484FAAHA AU52LFIAHA Electrical Wiring C1 C2 R R C1 C2 R S T N L m 1 L m 2 N o t e : 1 : L ( b l a c k ) 2 : N ( w h i t e ) 3 : C ( r e d ) - - - - I t ' s n o u s e f o r B u i l t i n E E V T y p e o n t h e i n d o o r u n i t . U V W CM Compres...
Page 29 - ON; to be applied for a necessary situation
Matrix of the dial switch and indoor unit number Field setting Field setting the unit number Indoor unit number setting Indoor unit number setting switch and confirmation of the settings. There is a 4-position dial switch for setting the indoor unit number and fan speed level on the computer board o...
Page 30 - The unit has temperature compensation function.; Only used for remote controller
Item to the checked Pay special care to the following and check after installation Unproper installation may cause Check Is gas leakage check performed?Is unit properly insulated?Is water drainage smooth?Is power voltage meet that stipulated on the nameplate?Is wiring and piping correctly arranged?I...
Page 31 - Technical Specifications
heating Capacity 710*440*270 710*440*270 840*840*240 840*840*240 860*500*60 860*500*60 950*950*80 950*950*80 42dB(A) 37dB(A) heating Capacity 950*950*80 950*950*80 6.35/12.7 6.35/12.7 9.52/15.88 9.52/15.88 9.52/19.05 9.52/19.05 29 Cooling Capacity Model Power Supply 7200W 8000W 1PH.220V~,60Hz 28kg 1...