Page 2 - Warning Symbol; Caution Symbol; CAUTION; WARNING; EQUIPMENT MISUSE HAZARD
2 306926 Table of Contents Warnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Troubleshoo...
Page 3 - INJECTION HAZARD; FIRE AND EXPLOSION HAZARD; MOVING PARTS HAZARD
3 306926 WARNING INJECTION HAZARD Spray from the gun, leaks or ruptured components can inject fluid into your body and cause extremelyserious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can alsocause serious injury. D Fluid injected into the skin is a serious...
Page 4 - Installation; General Information
4 306926 Installation Grounding WARNING FIRE AND EXPLOSION HAZARD Before operating the pump, ground thesystem as explained below. Also readthe section FIRE AND EXPLOSION HAZARD on page 3. Although water generally provides a natural electricalground, the following equipment must be grounded ifthe cle...
Page 5 - Pump Setup
5 306926 Installation 06649B Fig. 2 2 18 28 B A 35 22 E D E 24 F 16 C 10 47 Pump Setup See Fig. 2. Connect the suction hose (28) between thepump inlet (A) and the suction tube (18), using threadsealant on the male threads. Screw on the suctiontube filter (B). Place the suction tube in the supplydrum...
Page 6 - Operation; Pump Operation
6 306926 Operation Pressure Relief Procedure WARNING INJECTION HAZARD Fluid under high pressure can be in-jected through the skin and cause seri-ous injury. To reduce the risk of an injury from injection, splashing fluid, or moving parts, fol-low the Pressure Relief Procedure whenever you: D are ins...
Page 7 - Useful Hints; Shutdown and Care of the Sprayer
7 306926 Operation WARNING To reduce the risk of overpressurizing the sprayer,NEVER exceed 1000 psi (6.9 MPa, 69 bar) Maxi-mum Working Pressure. If you add any accesso-ries to the fluid line, be sure they are rated for atleast 1000 psi (6.9 MPa, 69 bar) working pressure. Adjust the air line lubricat...
Page 8 - Troubleshooting
8 306926 Troubleshooting NOTE: Refer to the separate instruction manuals which are supplied with this sprayer, and the manualswhich are supplied with any accessories you added,for complete operation, troubleshooting and repairinstructions. NOTE: Check all possible problems and solutions before disas...
Page 9 - Pump Performance Chart; Technical Data
9 306926 Pump Performance Chart 7 cycles per gallon (3.8 liter)Maximum recommended continuous speed: 60 cycles/min: 8 gpm (29 liter/min) 40 psi (0.3 MPa, 3 bar) AIR SUPPLY TO PUMP 70 psi (0.5 MPa, 5 bar) AIR SUPPLY TO PUMP 100 psi (0.7 MPa, 7 bar) AIR SUPPLY TO PUMP SPRAY TIP ORIFICE SIZE GPM (l/min...
Page 10 - Parts
10 306926 Parts 7663B 47 42 21 24 1e, 1f, 1g Detail B 23 18 15 19 26 17 28 29 22 Detail A 10 16 Detail B Detail A 2 30 33 32 34 1 35 31 46 48 1a 1b 1c 1d
Page 12 - Graco Standard Warranty; Graco Phone Numbers
12 306926 Graco Standard Warranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on thedate of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limit...