Page 2 - Models; SDM5 Manual Dispense Electronic Meters
Models 2 312865R Models SDM5 Manual Dispense Electronic Meters Model Number Swivel Extension Description Nozzle Fluid Type 255348 1/2” npt(f) Flexible Extension Automatic, non-drip, quick close Oil 255349 1/2” npt(f) Gear Lube Extension Non-drip, quick close Gear Lube 255350 1/2” npt(f) Rigid Extens...
Page 3 - SDM15 Manual Dispense Electronic Meters
Models 312865R 3 SDM15 Manual Dispense Electronic Meters Model Number Swivel Extension Description Nozzle Fluid Type 255800 3/4” npt(f) Rigid Extension Non-drip, quick close Oil or Antifreeze 255801 3/4” npt(f) Flexible Extension Non-drip, quick close Oil or Antifreeze 256836 1/2” npt(f) Rigid Exten...
Page 4 - SDP5 Preset Dispense Electronic Meters
Models 4 312865R SDP5 Preset Dispense Electronic Meters Model Number Swivel Extension Description Nozzle Fluid Type 255200 1/2” npt(f) Rigid Extension Automatic, non-drip, quick close Oil 255351 1/2” npt(f) Flexible Extension Automatic, Non-drip, quick close Oil 255352 1/2” npt(f) Gear Lube Extensio...
Page 5 - SDP15 Preset Dispense Electronic Meters
Models 312865R 5 SDP15 Preset Dispense Electronic Meters Model Number Swivel Extension Description Nozzle Fluid Type 255353 3/4” npt(f) Rigid Extension Non-drip, quick close Oil or Antifreeze 255354 3/4” npt(f) Flexible Extension Non-drip, quick close Oil or Antifreeze 256838 1/2” npt(f) Rigid Exten...
Page 6 - Warnings; WARNING
Warnings 6 312865R Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-sp...
Page 7 - FIRE AND EXPLOSION HAZARD
Warnings 312865R 7 FIRE AND EXPLOSION HAZARD When flammable fluids are present in the work area, such as gasoline and windshield wiper fluid, be aware that flammable fumes can ignite or explode. To help prevent fire and explosion:• Use equipment only in well ventilated area. • Eliminate all ignition...
Page 8 - Installation; Typical Installations (F; IG; IG; Drum Mount Bracket (F; IG; ITEM DESCRIPTION
Installation 8 312865R Installation Typical Installations (F IG . 1) The typical installation shown in F IG . 1 is only a guide. It is not a complete system design. Contact your Graco distributor for assistance in designing a system to suit your needs. Mounting Bracket (F IG . 2) Mounting Bracket Ki...
Page 9 - Pressure Relief Procedure; Grounding; Fluid supply container:; Pre-Installation Procedure; Relieve pressure; Installation Procedure; Flushing; FIRE HAZARD
Installation 312865R 9 Pressure Relief Procedure This equipment will stay pressurized until the pressure has been manually relieved. To reduce the risk of serious injury from pressurized fluid, accidental spray from the dispense valve or splashing fluid, follow this Pressure Relief Procedure when ev...
Page 10 - Installing Tube Extension (F
Installation 10 312865R 3. Slowly open the main fluid valve. a. Place the hose end (with no dispense valve connected) into a container for waste oil. b. Secure the hose in the container so it will not come out during flushing. c. If you have multiple dispense positions, first flush the dispense posi...
Page 11 - Do not trigger meter when nozzle is closed
Installation 312865R 11 Installing Nozzle (F IG . 6) 1. a. Thread new nozzle (33) onto extension (20). b. With an open-end adjustable wrench on flats of nozzle bushing, tighten firmly. 2. Open automatic twist lock nozzle and all fluid shut-off valves. Start pump to pressurize system. See Operation S...
Page 12 - Meter Overview; Navigation and Modes; Meter Display; Adjusting Screen Contrast using ARROWS; Locking and Unlocking Trigger; only
Meter Overview 12 312865R Meter Overview Navigation and Modes 5-Way Menu Navigation Button (F IG . 7) • Includes 4 direction ARROWS (UP, DOWN, LEFT, RIGHT) and a center, ENTER button. • Pressing the direction ARROWS allows user to easily scroll through menus. To select/store your selection, you must...
Page 13 - Setup Mode Screens; To display the Home Screen:; MANUAL
Setup Mode Screens 312865R 13 Setup Mode Screens If you are in Operation Mode you must be on the Home Screen shown in F IG . 10, to access the Setup Mode Screens. ( A complete description of the Home Screen is provided on page 20). To display the Home Screen: 1. Wake up the meter by pressing any but...
Page 14 - Main Screen Features (F; A. Screen Identifier Icon
Setup Mode Screens 14 312865R Main Setup Screen (F IG . 12) All Meters The Main Setup Screen is the first screen displayed when you enter the Setup Mode. This screen displays a list of the available Setup Screens and also includes a link back to the Home Screen. Manual Meters Screens: • UNITS/LIMIT ...
Page 15 - Set Measurement Units; Set Manual
Setup Mode Screens 312865R 15 Units/Limit Screen (F IG . 13) For All Meters Sets the units of measurement to pints, quarts, liters, or gallons. Units/Limit Screen Features (F IG . 13) All meters include C - E C. Units Mode : Displays measurement unit that was selected using the Set Measurement Units...
Page 17 - OR; To attain the most accurate calibration:
Setup Mode Screens 312865R 17 Recalibrating the Meter (F IG . 14) The meter is shipped from the factory with the default calibration factor for 10W30 motor oil - at 70°F (21°C). This calibration factor is sufficiently accurate for most oils. If other fluids are used or if greater accuracy is require...
Page 18 - Preset Meters include D, P and Q; PRESET
Setup Mode Screens 18 312865R Preset Screen (F IG . 15) For Preset Meters Only Sets the default preset amounts. Typically, you would enter amounts you most frequently dispense. Preset Meters include D, P and Q D. Wrench Icon: Returns user to Main Screen. P. Measurement Unit: Set on Units/Limit Scree...
Page 19 - Banner Screen Features D and R; To select your language:; M O B I L 1 5 W; ENGLISH
Setup Mode Screens 312865R 19 Banner Screen (F IG . 16) For All Meters Creates the information banner displayed across top of the Home, Manual and Preset Screens. Banner Screen Features D and R D. Wrench Icon: Returns user to Main Screen. R. Banner field: Information line. Provides space for up to 1...
Page 20 - Dispensing Fluid and Operation Mode Screens; All Meters include Include A - D; Setup Mode Banner Screen
Dispensing Fluid and Operation Mode Screens 20 312865R Dispensing Fluid and Operation Mode Screens If you are in the Setup Mode, to display the Operation Mode Screens use the UP or DOWN ARROW button to select HOME from the list. Press the Center ENTER button to display the Operation Mode Home Screen...
Page 21 - Manual Dispense
Dispensing Fluid and Operation Mode Screens 312865R 21 Manual Dispense (F IG . 19) All Meters See F IG . 19 for terms D - H D. Information Banner: Configurable information banner. Data is input on Setup Mode Banner Screen , page 19. E. Unit of Measurement : Identifies unit of measurement, pint, quar...
Page 22 - E. Unit of Measurement
Dispensing Fluid and Operation Mode Screens 22 312865R Preset Dispense (F IG . 22) Preset Meters Only See F IG . 22 for terms D - L D. Information Banner: Configurable information banner. Data is input in Setup Mode, Banner Screen, page 19. E. Unit of Measurement : Identifies unit of measurement, pi...
Page 23 - To modify the amount selected:; To set Preset amounts:
Dispensing Fluid and Operation Mode Screens 312865R 23 To modify the amount selected: a. Use the UP or DOWN ARROW to scroll up or down to increase or decrease the amount shown in field L. Each time you press the UP or DOWN ARROW the amount will increase or decrease in increments of 0.1 units. To spe...
Page 24 - To dispense in Preset Mode:
Dispensing Fluid and Operation Mode Screens 24 312865R To dispense in Preset Mode: If the display was asleep , press any button to wake up the display. 1. From HOME screen, use the UP or DOWN ARROWS to select PRESET (F IG . 24). 2. Press center, ENTER button to confirm selec- tion.The Preset Dispens...
Page 25 - To display Totals Screen:
Dispensing Fluid and Operation Mode Screens 312865R 25 Totals Screen (F IG . 26) All Meters See F IG . 26 for terms F, G, M - P F. Home Icon: Returns user to Home Screen. G. Reset: Resets counter (M) to zero. M. Resettable Total: Shows cumulative amount that has been dispensed in all modes. Can be r...
Page 26 - Troubleshooting; Problem
Troubleshooting 26 312865R Troubleshooting • Relieve pressure , page 9, before you check or repair the meter. Be sure all other valves, controls and pump are operating properly. • When calling for Technical Assistance you may be asked to provide the Software Version that is being used by your meter....
Page 28 - Error Codes; Error Code
Troubleshooting 28 312865R Error Codes Error codes are listed below. Even in an error condition the unit keeps track of the amount dispensed. With any error code displayed you can: • Select Manual option on Home Screen. Error code is cleared. Unit switches to Manual mode and dispensed amount is disp...
Page 29 - Service; Replacing the Battery
Service 312865R 29 Service See Parts List, page 43, for reference numbers included in the following Service instructions. Replacing the Battery The low battery and dead battery displays are explained in the Troubleshooting Table, page 26. To change the battery: 1. Press firmly on battery compartment...
Page 30 - Trip Rod Repair; Disassembly; Relieve Pressure; Do not
Service 30 312865R Trip Rod Repair (SDP5 & SDP15 Meters Only) Disassembly 1. Relieve Pressure , page 9. 2. Use a Torx (T20) wrench to remove 4 corner screws (A) located on the bottom of the meter (F IG . 30). Keep these screws for reassembly. 3. Turn meter over and tilt cover back (F IG . 31). 4...
Page 32 - Cleaning Trip Rod
Service 32 312865R 10. Place meter in a vise as shown in F IG . 38. Use new trip rod from your kit (2) or a non-metal rod or dowel to push trip rod through meter housing (F IG . 38 and F IG . 39) far enough to access pin (19) holding together trip rod and trigger. 11. Use a pick to push pin (19) out...
Page 33 - Reassembly
Service 312865R 33 Reassembly Use all the new parts provided in the kit. Do not reuse the old parts. 1. Insert balls (3) in trip rod (2) (F IG . 42). 2. Slide spring (1) over trip rod (2) (F IG . 42). 3. Insert trip rod assembly in opening in meter housing (F IG . 43). 4. Turn meter over and place i...
Page 36 - SDM5 & SDM15 Manual Meters Parts
SDM5 & SDM15 Manual Meters Parts 36 312865R SDM5 & SDM15 Manual Meters Parts ( Replacement Danger and Warning labels, tags and cards are available at no cost. Ref Part Description Qty 2 115477 SCREW, mach, torx pan hd 6 5 120812 O-RING, seal 1 6 15K418 TRIGGER, meter 1 9 15K464 GUARD, bump...
Page 38 - SDP5 & SDP 15 Preset Meters Parts
SDP5 & SDP 15 Preset Meters Parts 38 312865R SDP5 & SDP 15 Preset Meters Parts ( Replacement Danger and Warning labels, tags and cards are available at no cost. Ref Part Description Qty 2 115477 SCREW, mach, torx pan hd 6 3 255889 KIt, repair, trip rod, includes 3a-3c and instruction manua...
Page 41 - Description
Nozzle (33) and Extension (20) Kits 312865R 41 255857 Non-drip, quick close, high-flow nozzle with rigid extension Oil and Anti-freeze 255858 Non-drip, quick close, high flow nozzle with flexible extension Oil and Anti-freeze Part No. Description Fluid Type ti11826 ti11829 ti11825 ti11829
Page 43 - Technical Data
Technical Data 312865R 43 Technical Data *Tested in 10W motor oil. Flow rates vary with fluid pressure, temperature and viscosity. **Battery required to meet life expectancy: Energizer ® Alkaline E91 . † At 2.5 gpm (9.5 lpm), at 70°F (21°C), with 10-weight oil and 1 gallon dispensed. May require cal...
Page 44 - Graco Extended Metered Dispense Valve Warranty; Graco Information
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. For patent information, see www.graco.com/patents. Original instructions. This manual contains Eng...