Page 2 - CAUTION
Before you use the SHERWIN WILLIAMS PT2500 Sprayer, please read this en- tire instruction manual. The manual contains important information that will helpyou operate the sprayer safely and efficiently, and will help you keep the sprayer intop operating condition. Table of Contents Terms 2 . . . . . ...
Page 4 - WARNINGS; FLUID INJECTION HAZARD
WARNINGS High Pressure Spray Can Cause Serious Injury. For Professional Use Only. Observe All Warnings. Read and understand all instruction manuals before operating equipment. FLUID INJECTION HAZARD General Safety This equipment generates very high fluid pressure. Spray fromthe gun, leaks or rupture...
Page 5 - EQUIPMENT MISUSE HAZARD; FIRE OR EXPLOSION HAZARD; HOSE SAFETY
EQUIPMENT MISUSE HAZARD General Safety Misuse of the spray equipment or accessories, such as overpressurizing, modifying parts, using incompatible chemicalsand fluids, or using worn or damaged parts, can cause them torupture and result in fluid injection, splashing in the eyes or theskin, or other i...
Page 6 - Avertissement; RISQUES D’INJECTION; RISQUES EN CAS DE MAUVAISE UTILISATION DU MATERIAL
Avertissement La pulvérisation à haute pression peut causer des blessures très graves. Réservé exclusivement à l’usage professionnel. Observer toutes les consignes de sécurité. Bien lire et bien comprendre tous les manuels d’instructions avant d’utiliser le matériel. RISQUES D’INJECTION Consignes gé...
Page 7 - MESURES DE SECURITE CONCERNANT LES TUYAUX FLEXIBLES; RISQUES D’INCENDIE OU D’EXPLOSION
Ne jamais altére ou modifier une pièce de cet appareil; ceci ris-querait d’entraîner son mauvais fonctionnement. Verifier régulièrement tout l’appareil de pulvérisation et seséquipements et réparer ou remplacer immédiatement lespièces usées ou abîmées. Toujours porter une protection pour les yeux, d...
Page 8 - ADVERTENCIA; PELIGRO DE INYECCION DE FLUIDO
ADVERTENCIA EL ROCIADO a ALTA PRESIÓN PUEDE CAUSAR GRAVES LESIONES. SOLO PARA USO PROFESIONAL. RESPETE LOS AVISOS DE ADVERTENCIA. Lea y entienda todo el manual de instrucciónes antes de manejar el equipo. PELIGRO DE INYECCION DE FLUIDO Seguridad general Este equipo general un fluido a una presión mu...
Page 9 - PELIGRO POR MAL USO DEL EQUIPO; PELIGRO DE INCENDIO O EXPLOSION; SEGURIDAD EN EL USO DE LAS MANGUERAS
PELIGRO POR MAL USO DEL EQUIPO Seguridad general Cualquier mal uso del equipo pulverizador o los accesorios, talcomo sobre presurización, modificación de piezas, uso de ma-teriales y productos químicos incompatibles, o utilización depiezas dañadas o desgastadas, puede hacen que se rompany causen la ...
Page 10 - Setup
Setup 1. Prepare the paint according to the manufactur-er’s recommendations. This is probably the most important step toward trouble-free spraying! Remove any skin that may have formed on the topof the paint. If necessary, thin the paint. Finally,strain the paint through a fine nylon mesh bag(availa...
Page 11 - Startup
Startup CAUTION The wallet sized warning card provided with the gunshould be kept with the operator at all times. The cardcontains important information on reducing the risk ofa fluid injection injury, and treatment informationshould an injection injury occur. Additional copies ofthis card are avail...
Page 13 - Maintenance
Maintenance CAUTION Thorough flushing and proper maintenance areessential to keep the sprayer working properlyand avoid costly damage to the sprayer or the ob-ject being sprayed. Diaphragm Failure: Always replace the diaphragmafter every 500 hours of operation (once every 4 to 6months). The diaphrag...
Page 15 - Application Methods; RIGHT
Application Methods Always hold the gun perpendicular to the surface andkeep the gun at an even 12 to 14 inch (300 to 356 mm)from the surface you are spraying. See Fig. 12. Begin moving the gun in a horizontal direction at a steadyrate. Start the spray stroke off the target surface and pullthe trigg...
Page 16 - Troubleshooting; WARNING
Troubleshooting WARNING To reduce the risk of injury, including fluid injection, al-ways follow the Pressure Relief Procedure Warn-ing on page 11 before checking or repairing any partof the spray system. NOTE: Repairs, other than those for which instructionsare given on page 18, should be performed ...
Page 18 - Service
Service Repairs, other than those for which instructions are givenbelow, should be performed by a trained and qualified re-pair agency. WARNING To reduce the risk of injury, including fluid injection,splashing in the eyes or on the skin, or injury frommoving parts, always follow the Pressure ReliefP...
Page 20 - Parts
Parts 38 34 56 37 60 1 59 54 55 86 56 8 70 13 14 71 9 65 49 50 48 53 7 89 6 5 52 4 4a 40 47 45 46 44 64 42 43 66 35 3 63 67 2 16 19 27 18 41 39 61 62 37 36 33 17 92 97 95 405758 0280 98 99 75 1 34 2 Lubricate the threads. Torque to 40–45 in–lb(54–60 N.m). Torque to 130–140 in–lb (15–16 N.m). Apply P...
Page 24 - Technical Data; Graco Phone; The Sherwin-Williams Warranty and Disclaimers
Technical Data Power Requirements 120 VAC, 60 Hz, . . . . . . . . . . . . . . 1 Phase, 15 AMP minimum Pressure Operating Range 0–3000 psi . . . . . . . . . . . . . . (0 – 210 bar) Maximum Delivery 0.28 GPM (1.1 liter/min) . . . . . . . . . . Power Cord No. 16 AWG, 3 wire, . . . . . . . . . . . . . ....