Graco GE-DS-242-POE - Manuals
Graco GE-DS-242-POE – Manual in PDF format online.
Manuals:
Manual Graco GE-DS-242-POE
Summary
GE-DS-242-PoE Managed Ethernet Switch User Manual i Content Chapter 1 Introduction 1 Package Contents 2 Product Description 2 How to Use this Manual 3 Product Features 4 Product Specifications 7 Chapter 2 Installation 11 Hardware Description 12 Switch Installation 15 Chapter 3 Switch Management 21 R...
ii GE-DS-242-PoE Managed Ethernet Switch User Manual Chapter 6 Command Line Interface 127 Operation Notice 127 System Commands 128 Switch Static Configuration 129 Trunk Configuration 135 VLAN Configuration 138 Misc Configuration 147 Administration Configuration 149 MAC limit 154 Port Mirroring Confi...
GE-DS-242-PoE Managed Ethernet Switch User Manual 1 Chapter 1 Introduction The GE Security GE-DS-242-PoE offers 24 10/100Mbps Fast Ethernet ports with 2 Gigabit TP/SFP combo ports (Port-25, 26). The two Gigabit TP/SFP combo ports can be either 1000Base-T for 10/100/1000Mbps or 1000Base-SX/LX through...
Chapter 1: Introduction 2 GE-DS-242-PoE Managed Ethernet Switch User Manual Package Contents What’s in the box Open the Managed Switch box and carefully unpack it. The box should contain the following items: The Managed Switch x1 User’s manual CD x1 Installation Sheet x1 19” Rack mount accessory kit...
Chapter 1: Introduction GE-DS-242-PoE Managed Ethernet Switch User Manual 3 Power Over Ethernet The PoE in-line power following the standard IEEE 802.3af makes the GE-DS-242-PoE able to power on 24 PoE devices at a distance of up to 100 meters through the 4-pair Cat 5/5e UTP wire. Cost-effective sol...
Chapter 1: Introduction 4 GE-DS-242-PoE Managed Ethernet Switch User Manual Product Features • Physical Port o 24-Port 10/100Base-TX RJ-45 with PoE Injector o 2-Port Gigabit TP/SFP combo interfaces o Reset button for system management o 1 RS-232 male DB9 console interface for Switch basic management...
Chapter 1: Introduction GE-DS-242-PoE Managed Ethernet Switch User Manual 7 Product Specifications GE-DS-242-PoE HARDWARE SPECIFICATIONS 10/100Mbps Copper Ports 24 10/100Base-TX RJ-45 Auto-MDI/MDI-X ports 1000Mbps Copper Ports 2 10/100/1000Base-T RJ-45 port SFP/mini-GBIC Slots 2 SFP interfaces, shar...
Chapter 2: Installation 12 GE-DS-242-PoE Managed Ethernet Switch User Manual Hardware Description Switch Front Panel The Switches front panel provides a simple interface for monitoring the Managed Switch. Figure 2-1 shows the front panel of the Managed Switch. Figure 2-1: GE-DS-242-PoE Switch front ...
Chapter 2: Installation GE-DS-242-PoE Managed Ethernet Switch User Manual 13 Reset button At the left of front panel, the Reset button is designed to reboot the Managed Switch without turning the power off. The following table summarizes the Reset button functions: Reset Button Pressed and Released ...
Chapter 2: Installation 14 GE-DS-242-PoE Managed Ethernet Switch User Manual • System LED Color Function PWR Green Lit: indicates there is power to the Switch • Per 10/100Base-TX, PoE interfaces (Port-1 to Port-24) LED Color Function LNK/ACT Green Lit: indicates the link through that port is success...
Chapter 2: Installation GE-DS-242-PoE Managed Ethernet Switch User Manual 15 Switch Rear Panel The rear panel of the Managed Switch includes an AC inlet power socket, which accepts input power from 100 to 240VAC, 50-60 Hz. Figure 2-3 shows the rear panel of the Managed Switch. Figure 2-3: GE-DS-242-...
Chapter 2: Installation 16 GE-DS-242-PoE Managed Ethernet Switch User Manual Step 3: Ensure there is enough ventilation space between the Managed Switch and surrounding objects. Figure 2-4: Typical placement of GE-DS-242-PoE on desktop NOTE: Connection to the Managed Switch requires UTP Category 5 n...
Chapter 2: Installation GE-DS-242-PoE Managed Ethernet Switch User Manual 17 Step 1: Place the Managed Switch on a hard flat surface, with the front panel positioned towards the front. CAUTION: Use only the screws supplied with the mounting brackets. Damage caused by using incorrect screws will inva...
Chapter 2: Installation 18 GE-DS-242-PoE Managed Ethernet Switch User Manual Step 6: Follow steps 4 and 5 of the Desktop Installation section to connect the network cabling and supply power to the Managed Switch. SFP Transceiver Installation This section describes how to insert an SFP transceiver in...
Chapter 2: Installation GE-DS-242-PoE Managed Ethernet Switch User Manual 19 Before connecting the other switches, workstations or Media Converter: 1. Make sure both sides of the SFP transceiver are the same media type (for example: 1000Base-SX to 1000Base-SX, 1000Bas-LX to 1000Base-LX). 2. Verify t...
GE-DS-242-PoE Managed Ethernet Switch User Manual 21 Chapter 3 Switch Management This chapter explains the methods that you can use to configure management access to the Managed Switch. It describes the types of management applications and the communication and management protocols that deliver data...
Chapter 3: Switch Management GE-DS-242-PoE Managed Ethernet Switch User Manual 23 Table 3-1: Management Methods Comparison Method Advantages Disadvantages Web Browser • Ideal for configuring the switch remotely • Compatible with all popular browsers • Can be accessed from any location • Most visuall...
Chapter 3: Switch Management GE-DS-242-PoE Managed Ethernet Switch User Manual 25 SNMP-Based Network Management You can use an external SNMP-based application to configure and manage the Managed Switch, such as SNMPc Network Manager, HP Openview Network Node Management (NNM) or What'sup Gold. This m...
Chapter 3: Switch Management 26 GE-DS-242-PoE Managed Ethernet Switch User Manual Figure 3-4: Console management setup Direct Access Direct access to the administration console is achieved by directly connecting a terminal or a PC equipped with a terminal-emulation program (such as HyperTerminal) to...
Chapter 3: Switch Management GE-DS-242-PoE Managed Ethernet Switch User Manual 27 You can change these settings, if desired, after you log on. This management method is often preferred because you can remain connected and monitor the system during system reboots. Also, certain error messages are sen...
Chapter 3: Switch Management 28 GE-DS-242-PoE Managed Ethernet Switch User Manual devices and data-collection programs. SNMP runs on top of the User Datagram Protocol (UDP), offering a connectionless-mode service. Management Architecture All of the management application modules use the same Messagi...
GE-DS-242-PoE Managed Ethernet Switch User Manual 29 Chapter 4 Web-Based Management Summary This section introduces the configuration and functions of the Web-Based management. About Web-based Management The Managed Switch offers management features that allow users to manage the Managed Switch from...
Chapter 4: Web-Based Management 30 GE-DS-242-PoE Managed Ethernet Switch User Manual Requirements • Workstations of subscribers running Windows 98/ME, NT4.0, 2000/2003/XP, MAC OS9 or later, Linux, UNIX or other platform compatible with TCP/IP protocols. • Workstation installed with Ethernet NIC (Net...
Chapter 4: Web-Based Management 32 GE-DS-242-PoE Managed Ethernet Switch User Manual NOTE: • We recommend using Internet Explorer 6.0 or above to access Managed Switch. • A changed IP address take effect immediately after click on the Save button, you need to use the new IP address to access the Web...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 33 The port states are illustrated as follows: State Disabled Down Link RJ-45 Ports SFP Ports PoE Ports Main Menu Using the onboard web agent, you can define system parameters, manage and control the Managed Switch, an...
Chapter 4: Web-Based Management 34 GE-DS-242-PoE Managed Ethernet Switch User Manual System Use the System menu items to display and configure basic administrative details of the Managed Switch. Under System the following topics are provided to configure and view the system information: This section...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 35 This page includes the following fields: OBJECT DESCRIPTION MODEL NAME Displays the system name of the Managed Switch DESCRIPTION Describes the Managed Switch MAC ADDRESS Displays the unique hardware address assigne...
Chapter 4: Web-Based Management 36 GE-DS-242-PoE Managed Ethernet Switch User Manual This page includes the following fields: OBJECT DESCRIPTION MAC Address Age-out Time Type the number of seconds that an inactive MAC address remains in the switch's address table. The value is a multiple of 6. Defau...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 39 SNMP Configuration SNMP Overview The Simple Network Management Protocol (SNMP) is an application layer protocol that facilitates the exchange of management information between network devices. It is part of the Tran...
Chapter 4: Web-Based Management 40 GE-DS-242-PoE Managed Ethernet Switch User Manual • Management information base (MIB): A MIB is a collection of managed objects residing in a virtual information store. Collections of related managed objects are defined in specific MIB modules. • Network-management...
Chapter 4: Web-Based Management 42 GE-DS-242-PoE Managed Ethernet Switch User Manual Community Strings Community strings serve as passwords and can be entered as one of the following: Figure 4-11: Community strings interface This page includes the following fields: OBJECT DESCRIPTION Community Strin...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 43 This page includes the following fields: OBJECT DESCRIPTION IP Address Enter the IP address of the trap manager. Community Enter the community string for the trap station. Firmware Upgrade It provides the functions ...
Chapter 4: Web-Based Management 44 GE-DS-242-PoE Managed Ethernet Switch User Manual Figure 4-14: HTTP Firmware Upgrade interface To open Firmware Upgrade screen, perform the following: 1. Click System -> Web Firmware Upgrade . 2. The Firmware Upgrade screen is displayed as in Figure 4-14. 3. Cli...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 45 Figure 4-15: Configuration Restore interface This page includes the following fields: OBJECT DESCRIPTION TFTP Server IP Address Type in your TFTP server IP. Restore File Name Type in the correct file name for restor...
Chapter 4: Web-Based Management 46 GE-DS-242-PoE Managed Ethernet Switch User Manual This page includes the following fields: OBJECT DESCRIPTION TFTP Server IP Address Type in your TFTP server IP. Backup File Name Type in the file name. Factory Default Reset Switch to default configuration. Click th...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 47 System Reboot Reboot the Switch with a software reset. Click the reboot button to reboot the system. Figure 4-18: System Reboot interface
Chapter 4: Web-Based Management 48 GE-DS-242-PoE Managed Ethernet Switch User Manual Port Configuration In Port control you can configure the settings of each port to control the connection parameters, the status of each port is listed below. Figure 4-19: Port Control interface This page includes th...
Chapter 4: Web-Based Management 50 GE-DS-242-PoE Managed Ethernet Switch User Manual Port Status This page displays current port configurations and operating status - it is a ports' configurations summary table. Via the summary table, you can learn the status of each port at a glance, like Port Link...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 51 Port Statistics The following chart provides the current statistic information, which displays the real-time packet transfer status for each port. The user might use the information to plan and implement the network...
Chapter 4: Web-Based Management 52 GE-DS-242-PoE Managed Ethernet Switch User Manual OBJECT DESCRIPTION Packet Dropped The counts of dropped packet. Rx Bcast Packet The counts of broadcast packet. Rx Mcast Packet The counts of multicast packet. Port Sniffer The Port Sniffer (mirroring) is a method f...
Chapter 4: Web-Based Management 54 GE-DS-242-PoE Managed Ethernet Switch User Manual VLAN Configuration VLAN Overview A Virtual Local Area Network (VLAN) is a network topology configured according to a logical scheme rather than the physical layout. VLAN can be used to combine any collection of LAN ...
Chapter 4: Web-Based Management 56 GE-DS-242-PoE Managed Ethernet Switch User Manual 802.1Q Tag User Priority CFI VLAN ID (VID) 3 bits 1 bits 12 bits TPID (Tag Protocol Identifier) TCI (Tag Control Information) 2 bytes 2 bytes Preamble Destination Address Source Address VLAN TAG Ethernet Type Data F...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 57 for tagged packets, tag-aware and tag-unaware network devices can coexist on the same network. A switch port can have only one PVID, but can have as many VID as the switch has memory in its VLAN table to store them....
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 61 Understanding the nomenclature of the Switch • IEEE 802.1Q Tagged and Untagged Every port on an 802.1Q compliant switch can be configured as tagged or untagged. Tagged Ports with tagging enabled will put the VID num...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 63 Figure 4-29: 802.1Q VLAN Setting Web Page screen This page includes the following fields: OBJECT DESCRIPTION VLAN Name Use this optional field to specify a name for the VLAN. It can be up to 16 alphanumeric characte...
Chapter 4: Web-Based Management 64 GE-DS-242-PoE Managed Ethernet Switch User Manual NOTE: Enable 802.1Q VLAN, the all ports on the switch belong to default VLAN, VID is 1. The default VLAN can't be deleted. VLAN Filter • 802.1Q VLAN Port Configuration This page is used for configuring the Switch po...
Chapter 4: Web-Based Management 66 GE-DS-242-PoE Managed Ethernet Switch User Manual 802.1Q VLAN IEEE 802.1Q Tunneling (Q-in-Q) IEEE 802.1Q Tunneling (QinQ) is designed for service providers carrying traffic for multiple customers across their networks. QinQ tunneling is used to maintain customer-sp...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 67 In cases where a given service VLAN only has two member ports on the switch, the learning can be disabled for the particular VLAN and can therefore rely on flooding as the forwarding mechanism between the two ports....
Chapter 4: Web-Based Management 68 GE-DS-242-PoE Managed Ethernet Switch User Manual OBJECT DESCRIPTION Check Configures IEEE 802.1Q tunneling (QinQ) for an uplink port to another device within the service provider network. QinQ Uplink Cancel Configures IEEE 802.1Q tunneling (QinQ) for a client acce...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 69 Rapid Spanning Tree The Rapid Spanning Tree Protocol (RSTP) is an evolution of the Spanning Tree Protocol and provides for faster spanning tree convergence after a topology change. The system also supports STP and t...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 71 When STP is enabled using the default parameters, the path between source and destination stations in a switched network might not be ideal. For instance, connecting higher-speed links to a port that has a higher nu...
Chapter 4: Web-Based Management 72 GE-DS-242-PoE Managed Ethernet Switch User Manual Figure 4-33: STP Port State Transitions You can modify each port state by using management software. When you enable STP, every port on every switch in the network goes through the blocking state and then transition...
Chapter 4: Web-Based Management 74 GE-DS-242-PoE Managed Ethernet Switch User Manual Default Spanning-Tree Configuration Feature Default Value Enable state STP disabled for all ports Port priority 128 Port cost 0 Bridge Priority 32,768 NOTE: The Hello Time cannot be longer than the Max. Age. Otherwi...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 75 Figure 4-34: Before Applying the STA Rules In this example, only the default STP values are used. Figure 4-35: After Applying the STA Rules
Chapter 4: Web-Based Management 76 GE-DS-242-PoE Managed Ethernet Switch User Manual The switch with the lowest Bridge ID (switch C) was elected the root bridge, and the ports were selected to give a high port cost between switches B and C. The two (optional) Gigabit ports (default port cost = 4) on...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 77 This page includes the following fields: OBJECT DESCRIPTION RSTP mode The user must enable the RSTP function first before configuring the related parameters. Protocol Version A value used to specify the spanning tre...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 81 Trunking Port trunking is the combination of several ports or network cables to expand the connection speed beyond the limits of any one single port or network cable. The Managed Switch supports two types of port tr...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 83 NOTE: A trunk group, including member ports split between two switches, has to enable the LACP function of the two switches. Aggregator Information When you setup the LACP aggregator, you will see relational informa...
Chapter 4: Web-Based Management 84 GE-DS-242-PoE Managed Ethernet Switch User Manual This page includes the following fields: OBJECT DESCRIPTION Group Key This is a read-only column field that displays the trunk group ID. Port member This is a read-only column field that displays the members of this...
Chapter 4: Web-Based Management 86 GE-DS-242-PoE Managed Ethernet Switch User Manual State Activity Having set up the LACP aggregator on the tab of Aggregator Setting, you can configure the state activity for the members of the LACP trunk group. You can tick or cancel the checkbox beside the state l...
Chapter 4: Web-Based Management 88 GE-DS-242-PoE Managed Ethernet Switch User Manual Forwarding and Filtering The frames of Ethernet Packets contain a MAC address (SMAC address), which shows the MAC address of the equipment sending the frame. The SMAC address is used by the switch to automatically u...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 89 Static MAC Table You can add a static MAC address that remains in the switch's address table regardless of whether the device is physically connected to the switch. This saves the switch from having to re-learn a de...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 91 IGMP Snooping Theory The Internet Group Management Protocol (IGMP) lets host and routers share information about multicast groups memberships. IGMP snooping is a switch feature that monitors the exchange of IGMP mes...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 93 IGMP Versions 1 and 2 Multicast groups allow members to join or leave at any time. IGMP provides the method for members and multicast routers to communicate when joining or leaving a multicast group. IGMP version 1 ...
Chapter 4: Web-Based Management 94 GE-DS-242-PoE Managed Ethernet Switch User Manual The Time-to-Live (TTL) field of query messages is set to 1 so that the queries will not be forwarded to other sub networks. IGMP version 2 introduces some enhancements such as a method to elect a multicast queried f...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 95 IGMP Configuration The Switch support IP multicast, you can enable IGMP protocol on web management's switch setting advanced page, then the IGMP snooping information displays. IP multicast addresses range are from 2...
Chapter 4: Web-Based Management 96 GE-DS-242-PoE Managed Ethernet Switch User Manual QoS Configuration Understand QOS Quality of Service (QoS) is an advanced traffic prioritization feature that allows you to establish control over network traffic. QoS enables you to assign various grades of network ...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 97 QoS Configuration QoS settings allow customization of packet priority in order to facilitate delivery of data traffic that might be affected by latency problems. When CoS / 802.1p Tag Priority is applied, the Switch...
Chapter 4: Web-Based Management 98 GE-DS-242-PoE Managed Ethernet Switch User Manual Figure 4-56: QoS Configuration - 802.1Priority This page includes the following fields: OBJECT DESCRIPTION First Come First Service The sequence of packets sent is depend on arrival order. All High before Low The hi...
Chapter 4: Web-Based Management 100 GE-DS-242-PoE Managed Ethernet Switch User Manual DiffServ Code Point (DSCP) - is the traffic prioritization bits within an IP header that are encoded by certain applications and/or devices to indicate the level of service required by the packet across a network. ...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 101 Figure 4-58: QoS Configuration - TOS Priority This page includes the following fields: OBJECT DESCRIPTION TOS/DSCP Enable / Disable internal traffic class ( 0~7) to map the corresponding IP DSCP value. DSCP The val...
Chapter 4: Web-Based Management 102 GE-DS-242-PoE Managed Ethernet Switch User Manual Figure 4-59 : QoS Configuration - TOS/DSCP Port Status This page includes the following fields: OBJECT DESCRIPTION Port Number Indicate port 1 to port 26. TOS/DSCP Status Enable / Disable TOS/DSCP map to 802.1p pri...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 103 Figure 4-60: Access Control List (ACL) Web Page screen This page includes the following fields: IPv4 ACL OBJECT DESCRIPTION DEFAULT VALUE Group ID 1 ~ 247 (max. 247 ACL group). Action Permit / Deny. Permit: Permit ...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 105 OBJECT DESCRIPTION DEFAULT VALUE Port Set this field if Packet Type is IPv4, else ignore. 0~65535 If UDP port not find in UDP field, you can direct assign number. Port Id Source port id, from 1~26, 0 means don’t ca...
Chapter 4: Web-Based Management 106 GE-DS-242-PoE Managed Ethernet Switch User Manual Binding Let device that has specific IP address and MAC address can use network. We can set specific IP address, MAC address, VLAN id and port id to bind, and device can cross switch if all conditions match. Use bi...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 107 MAC Limit MAC limit allows users to set a maximum number of MAC addresses to be stored in the MAC address table. The MAC addresses chosen to be stored in MAC address table is the result of first-come-first-save pol...
Chapter 4: Web-Based Management 108 GE-DS-242-PoE Managed Ethernet Switch User Manual MAC Limit Port Status This table displays current MAC Limit status of each port. Figure 4-62: MAC Limit - MAC Limit Port Status This page includes the following fields: OBJECT DESCRIPTION Port Number Indicate port ...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 109 802.1X Configuration 802.1x is an IEEE authentication specification which prevents the client from accessing a wireless access point or wired switch until it provides authority, like the user name and password that...
Chapter 4: Web-Based Management 110 GE-DS-242-PoE Managed Ethernet Switch User Manual Client-the device (workstation) that requests access to the LAN and switch services and responds to requests from the switch. The workstation must be running 802.1X-compliant client software such as that offered in...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 111 NOTE: If 802.1X is not enabled or supported on the network access device, any EAPOL frames from the client are dropped. If the client does not receive an EAP-request/identity frame after three attempts to start aut...
Chapter 4: Web-Based Management 112 GE-DS-242-PoE Managed Ethernet Switch User Manual In contrast, when an 802.1X-enabled client connects to a port that is not running the 802.1X protocol, the client initiates the authentication process by sending the EAPOL-start frame. When no response is received,...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 115 Misc Configuration In this page, you can change the default configuration for the 802.1x standard: Figure 4-68: 802.1x Misc Configuration interface This page includes the following fields: OBJECT DESCRIPTION Quiet ...
Chapter 4: Web-Based Management 116 GE-DS-242-PoE Managed Ethernet Switch User Manual Power Over Ethernet Providing up to 24 PoE, in-line power interface, the GE-DS-242-PoE PoE Switch can easily build a power central-controlled IP phone system, IP Camera system, AP group for the enterprise. For inst...
Chapter 4: Web-Based Management GE-DS-242-PoE Managed Ethernet Switch User Manual 119 • PD Classifications A PD may be classified by the PSE based on the classification information provided by the PD. The intent of PD classification is to provide information about the maximum power required by the P...
GE-DS-242-PoE Managed Ethernet Switch User Manual 121 Chapter 5 Console Management Login in the Console Interface To configure the system via console mode, connect a serial cable to a COM port on a PC or notebook computer and to RJ-45 type serial (console) port of the Managed Switch. The console por...
Chapter 5: Console Management 122 GE-DS-242-PoE Managed Ethernet Switch User Manual Figure 5-1: GE-DS-242-PoE Console Login screen NOTE: For security reasons, please change and memorize the new username and password after this first setup. Username Max: 6, Min: 1 characters. Password Max: 6, Min: 1 ...
Chapter 5: Console Management GE-DS-242-PoE Managed Ethernet Switch User Manual 123 Configure IP address The GE-DS-242-PoE Managed Switch is shipped with default IP address as follows. IP Address : 192.168.0.100 Subnet Mask : 255.255.255.0 To check the current IP address or modify a new IP address f...
Chapter 5: Console Management GE-DS-242-PoE Managed Ethernet Switch User Manual 125 Commands Level The following table lists the CLI commands and descriptions. Modes Access Method Prompt Exit Method About This Model User EXEC Begin a session with your switch. switch> Enter logout or quit. The use...
GE-DS-242-PoE Managed Ethernet Switch User Manual 127 Chapter 6 Command Line Interface Operation Notice To enter the "configuration" mode, you need to be in the privileged mode, and then types in the command configure : Switch# configure Switch (config) #
Chapter 6: Command Line Interface 128 GE-DS-242-PoE Managed Ethernet Switch User Manual Command Line Editing Key Function <Ctrl>-B ; ← Moves the cursor back one character. <Ctrl>-D Deletes the character at the cursor. <Ctrl>-E Jumps to the end of the current command line. <Ctrl&...
Chapter 6: Command Line Interface GE-DS-242-PoE Managed Ethernet Switch User Manual 129 Switch Static Configuration Port Configuration and show status port state Description: Turn the port state on or off. Syntax: port state <on | off> [< port-list >] Parameters: <port-list> specif...
Chapter 6: Command Line Interface 130 GE-DS-242-PoE Managed Ethernet Switch User Manual port flow Description: Enable or disable port flow control. Syntax: port flow <enable | disable> <enable | disable> [< port-list >] Parameters: The first <enable | disable> enables or disa...
Chapter 6: Command Line Interface GE-DS-242-PoE Managed Ethernet Switch User Manual 135 Trunk Configuration Trunk allows the switch to combine ports so that they function like a single high-speed link. It can be used to increase the bandwidth to some devices to provide a high-speed link. For example...
Chapter 6: Command Line Interface 136 GE-DS-242-PoE Managed Ethernet Switch User Manual Lacp Description: Specifies the added trunk group to be LACP enabled. Syntax: lacp no-lacp specifies the added trunk group to be LACP disabled. Parameters: <port-list> specifies the ports to be set. <act...
Chapter 6: Command Line Interface GE-DS-242-PoE Managed Ethernet Switch User Manual 137 no lacp system-priority Description: Set LACP system priority to the default value 32768. show lacp status Description: Show LACP enable/disable status and system priority. show lacp Description: Show LACP inform...
Chapter 6: Command Line Interface 138 GE-DS-242-PoE Managed Ethernet Switch User Manual VLAN Configuration Virtual LANs A Virtual LAN (VLAN) is a logical network group that limits the broadcast domain. It allows you to isolate network traffic so only members of the VLAN receive traffic from the same...
Chapter 6: Command Line Interface GE-DS-242-PoE Managed Ethernet Switch User Manual 139 The difference between a port-based VLAN and a tag-based VLAN is that the tag-based VLAN truly divided the network into several logically connected LANs. Packets rambling around the switches can be forwarded more...
Chapter 6: Command Line Interface 140 GE-DS-242-PoE Managed Ethernet Switch User Manual Advanced 802.1Q VLAN Configuration Ingress filters configuration When a packet was received on a port, you can govern the switch to drop it or not if it is an untagged packet. Furthermore, if the received packet ...
Chapter 6: Command Line Interface GE-DS-242-PoE Managed Ethernet Switch User Manual 141 (cpu-port|no-cpu-port) specifies the CPU port belong this VLAN group. LIST specifies the ports to be set to VLAN members. [LIST] specifies the ports to be set to tagged members. If not entered, all members set to...
Chapter 6: Command Line Interface GE-DS-242-PoE Managed Ethernet Switch User Manual 143 show vlan static Description: Show static VLAN entry information. show vlan pvid Description: Show port default VLAN id. Syntax: show vlan pvid [LIST] Parameters: [LIST] specifies the ports to be showed. If not e...
Chapter 6: Command Line Interface GE-DS-242-PoE Managed Ethernet Switch User Manual 145 vlan filter Description: Set ingress filter rules. Syntax: vlan filter (enable | disable) (enable | disable) LIST Parameters: ( enable | disable ) specifies the non-members packet will be forwarded or not. If set...
Chapter 6: Command Line Interface 148 GE-DS-242-PoE Managed Ethernet Switch User Manual broadcast select Description: Select the Broadcast storm filter packet type: Unicast/Multicast : Flood unicast/multicast filter Control Packets : Control packets filter IP multicast : IP multicast packets filter ...
Chapter 6: Command Line Interface GE-DS-242-PoE Managed Ethernet Switch User Manual 149 Administration Configuration Change Username / Password hostname Description: Set switch name. Syntax: hostname < name-str > Parameters: < name-str > specifies the switch name. If you would like to ha...
Chapter 6: Command Line Interface 150 GE-DS-242-PoE Managed Ethernet Switch User Manual IP Configuration User can configure the IP setting and fill in a new value. ip address Description: Set IP address and subnet mask. Syntax: ip address < ip-addr > < ip-mask > ip default-gateway Descri...
Chapter 6: Command Line Interface GE-DS-242-PoE Managed Ethernet Switch User Manual 151 dhcp Description: Set switch as dhcp client, it can get ip from dhcp server. NOTE: If you set this command, the switch will reboot. show dhcp Description: Show dhcp enable/disable. Reboot switch boot Description:...
Chapter 6: Command Line Interface 152 GE-DS-242-PoE Managed Ethernet Switch User Manual TFTP Update Firmware copy tftp firmware Description: Download firmware from TFTP server. Syntax: copy tftp firmware < ip-addr > < remote-file > Parameters: < ip-addr > specifies the IP address o...
Chapter 6: Command Line Interface GE-DS-242-PoE Managed Ethernet Switch User Manual 153 Backup Configure File copy <running – config | flash> tftp Description: Send configuration to the TFTP server. If you want to save the configuration in a text file of CLI commands, use the keywordrunning-co...
Chapter 6: Command Line Interface 154 GE-DS-242-PoE Managed Ethernet Switch User Manual MAC limit MAC limit allows users to set a maximum number of MAC addresses to be stored in the MAC address table. The MAC addresses chosen to be stored in MAC address table is the result of first-come-first-save p...
Chapter 6: Command Line Interface GE-DS-242-PoE Managed Ethernet Switch User Manual 155 Port Mirroring Configuration Port monitoring is a feature to redirect the traffic occurred on every port to a designated monitoring port on the switch. With this feature, the network administrator can monitor and...
Chapter 6: Command Line Interface 156 GE-DS-242-PoE Managed Ethernet Switch User Manual Quality of Service There are four transmission queues with different priorities in the Managed Switch: Highest, SecHigh, SecLow and Lowest. The Managed Switch will take packets from the four queues according to i...
Chapter 6: Command Line Interface GE-DS-242-PoE Managed Ethernet Switch User Manual 157 priority packets sent before one lower priority packet is sent. For example, 8 Highest:4 second-high means that the switch sends 8 highest-priority packets before sending 4 second-high priority packets. • QoS lev...
Chapter 6: Command Line Interface 158 GE-DS-242-PoE Managed Ethernet Switch User Manual show qos Description: Show QoS configurations, including802.1p priority, priority level. e.g. Switch(config)# show qos QoS configurations: QoS mode: weighted round robin Highest weight: 8 Second High weight: 4 Se...
Chapter 6: Command Line Interface GE-DS-242-PoE Managed Ethernet Switch User Manual 159 MAC Address Configuration clear mac-address-table Description: Clear all dynamic MAC address table entries. mac-address-table static Description: Set static unicast or multicast MAC address. If multicast MAC addr...
Chapter 6: Command Line Interface 162 GE-DS-242-PoE Managed Ethernet Switch User Manual STP/RSTP Commands [no] spanning-tree Description: Enable or disable spanning-tree. spanning-tree forward-delay Description: Set spanning tree forward delay used, in seconds. Syntax: spanning-tree forward-delay &l...
Chapter 6: Command Line Interface GE-DS-242-PoE Managed Ethernet Switch User Manual 163 spanning-tree maximum-age Description: Set spanning tree maximum age, in seconds. Syntax: spanning-tree maximum-age <6-40> Parameters: <6-40> specifies the maximum age, in seconds. Default value is 20...
Chapter 6: Command Line Interface 164 GE-DS-242-PoE Managed Ethernet Switch User Manual spanning-tree port priority Description: Set spanning tree port priority. Syntax: spanning-tree port priority <0-240> [<port-list>] Parameters: <0-240> specifies the port priority. The value mus...
Chapter 6: Command Line Interface GE-DS-242-PoE Managed Ethernet Switch User Manual 165 spanning-tree protocol version Description: Change spanning tree protocol version. Syntax: spanning-tree protocol-version <stp | rstp> Parameters: stp specifies the original spanning tree protocol (STP,802....
Chapter 6: Command Line Interface 166 GE-DS-242-PoE Managed Ethernet Switch User Manual [no] spanning-tree port non-stp Description: Disable or enable spanning tree protocol on this port. Syntax: [no] spanning-tree port non-stp [<port-list>] Parameters: <port-list> specifies the ports to...
Chapter 6: Command Line Interface GE-DS-242-PoE Managed Ethernet Switch User Manual 167 SNMP Any Network Management running the simple Network Management Protocol (SNMP) can be management with the switch. System Options Snmp /no snmp Description: Enable or disable SNMP. Show snmp status Description:...
Chapter 6: Command Line Interface 168 GE-DS-242-PoE Managed Ethernet Switch User Manual Snmp system-location Description: Set agent location string. Syntax: snmp system-location <location-str> Parameters: <location-str> specifies the location string. e.g. snmp system-location office Snmp...
Chapter 6: Command Line Interface GE-DS-242-PoE Managed Ethernet Switch User Manual 169 Community Strings snmp community Description: Set SNMP community string. Syntax: snmp community <read-sysinfo-only | read-all-only | read-write-all><community-str> Parameters: <community-str> sp...
Chapter 6: Command Line Interface 170 GE-DS-242-PoE Managed Ethernet Switch User Manual Trap Managers snmp trap Description: Set SNMP trap receiver IP address, community string, and port number. Syntax: snmp trap <ip-addr> [<community-str>] [<1..65535>] Parameters: <ip-addr> ...
Chapter 6: Command Line Interface GE-DS-242-PoE Managed Ethernet Switch User Manual 171 IGMP The Internet Group Management Protocol (IGMP) is an internal protocol of the Internet Protocol (IP) suite. igmp Description: Enable/disable IGMP snooping. Syntax: [no] igmp igmp fastleave Description: Enable...
Chapter 6: Command Line Interface 172 GE-DS-242-PoE Managed Ethernet Switch User Manual igmp debug Description: Enable/disable IGMP snooping debugging output. Syntax: [no] igmp debug show igmp Description: Show IGMP snooping information. Syntax: show igmp <status | router | groups | table> Par...
Chapter 6: Command Line Interface GE-DS-242-PoE Managed Ethernet Switch User Manual 173 802.1x Protocol dot1x Description: Enable or disable 802.1x. Syntax: [no] dot1x radius-server host Description: Set radius server IP, port number, and accounting port number. Syntax: radius-server host <ip-add...
Chapter 6: Command Line Interface 176 GE-DS-242-PoE Managed Ethernet Switch User Manual show dot1x Description: Show 802.1x information, quiet period, Tx period, supplicant timeout, server timeout, maximum requests, and re-auth period. dot1x port Description: Set 802.1x per port information. Syntax:...
Chapter 6: Command Line Interface GE-DS-242-PoE Managed Ethernet Switch User Manual 177 Access Control List Packets can be forwarded or dropped by ACL rules include Ipv4 or non-Ipv4. The Managed Switch can be used to block packets by maintaining a table of packet fragments indexed by source and dest...
Chapter 6: Command Line Interface 178 GE-DS-242-PoE Managed Ethernet Switch User Manual show acl Description: Show ACL group information. Syntax: show acl [<1-220>] Parameters: <1-220> specifies the group id, null means all valid groups. e.g. Switch(config)# show acl 1 Group Id : 1 Switc...
Chapter 6: Command Line Interface GE-DS-242-PoE Managed Ethernet Switch User Manual 179 acl (add|edit) <1-220> (permit|deny) <0-4094> ipv4 <0-255> Description: Add or edit ACL group for Ipv4. Syntax: acl (add|edit) <1-220> (permit|deny) <0-4094> ipv4 <0-255> A.B.C...
Chapter 6: Command Line Interface 180 GE-DS-242-PoE Managed Ethernet Switch User Manual acl (add|edit) <1-220> (qosvoip) <0-4094> Description: Add or edit ACL group for Ipv4. Syntax: acl (add|edit) <1-220> (qosvoip) <0-4094> <0-7> <0-1F> <0-1F> <0-FF> ...
Chapter 6: Command Line Interface GE-DS-242-PoE Managed Ethernet Switch User Manual 181 acl (add|edit) <1-220> (permit|deny) <0-4094> nonipv4 <0-65535> Description: Add or edit ACL group for non-Ipv4. Syntax: acl (add|edit) <1-220> (permit|deny) <0-4094> nonipv4 <0-6...
Chapter 6: Command Line Interface 182 GE-DS-242-PoE Managed Ethernet Switch User Manual Binding Let device that has specific IP address and MAC address can use network. We can set specific IP address, MAC address, VLAN id and port id to bind, and device can cross switch if all conditions match. SIP/...
Chapter 6: Command Line Interface GE-DS-242-PoE Managed Ethernet Switch User Manual 183 show bind Description: Show Binding group information. Syntax: show bind [<1-220>] Parameters: <1-220> specifies the group id, null means all valid groups. e.g. show bind 1 bind add Description: Add B...
Chapter 6: Command Line Interface 184 GE-DS-242-PoE Managed Ethernet Switch User Manual Power over Ethernet Commands show poe Show System Power over Ethernet information show poe status Show PoE port information poe temperature-protection Enabling or disabling the PoE power supply over temperature p...
Chapter 6: Command Line Interface GE-DS-242-PoE Managed Ethernet Switch User Manual 185 show poe status Description: Show per PoE port information Command Level Global Configuration Syntax: show poe status [<port-list>] Parameters: <port-list> specifies the ports to be set. If not entere...
Chapter 6: Command Line Interface 186 GE-DS-242-PoE Managed Ethernet Switch User Manual Configure PoE Over Temperature Protection poe temperature-protection enable[x4] Description: Configure PoE over temperature protection to enable or disable Command Level Global Configuration Syntax: poe temperatu...
Chapter 6: Command Line Interface 188 GE-DS-242-PoE Managed Ethernet Switch User Manual Configure PoE -- Port poe enable Description: Enabling or disabling the port POE injects function. Command Level: Global Configuration Syntax: poe enable [<port-list>] [no] poe enable [<port-list>] Pa...
GE-DS-242-PoE Managed Ethernet Switch User Manual 191 Chapter 7 Switch Operation Address Table The Switch is implemented with an address table. This address table composed of many entries. Each entry is used to store the address information of some node in network, including MAC address, port no, et...
Chapter 8: Power Over Ethernet Overview 194 GE-DS-242-PoE Managed Ethernet Switch User Manual PoE System Architecture The specification of PoE typically requires two devices: the Powered Source Equipment (PSE) and the Powered Device (PD). The PSE is either an End-Span or a Mid-Span, while the PD is ...
Chapter 8: Power Over Ethernet Overview GE-DS-242-PoE Managed Ethernet Switch User Manual 195 The data pairs are used. Since Ethernet pairs are transformer coupled at each end, it is possible to apply DC power to the center tap of the isolation transformer without upsetting the data transfer. In thi...
Chapter 8: Power Over Ethernet Overview 196 GE-DS-242-PoE Managed Ethernet Switch User Manual http://www.poweroverethernet.com/articles.php?article_id=52 Microsemi /PowerDsine http://www.microsemi.com/PowerDsine/ Linear Tech http://www.linear.com/ The PoE Provision Process While adding PoE support t...
Chapter 8: Power Over Ethernet Overview GE-DS-242-PoE Managed Ethernet Switch User Manual 197 Line Detection Before power is applied, safety dictates that it must first be ensured that a valid PD is connected to the PSE's output. This process is referred to as "line detection", and involves ...
Chapter 8: Power Over Ethernet Overview 198 GE-DS-242-PoE Managed Ethernet Switch User Manual Operation During normal operation, the PSE provides 44-57 VDC, able to support a minimum of 15.4 watts power. Power Overloads The IEEE 802.3af standard defines handling of overload conditions. In the event ...
Chapter 9: Troubleshooting 202 GE-DS-242-PoE Managed Ethernet Switch User Manual 4. Make sure the cable is the right type 5. Turn off the power. After a while, turn on power again 100Base-TX port link LED is lit, but the traffic is irregular Solution: Check that the attached device is not set to ded...
Graco Manuals
-
Graco 04511 10F
Manual
-
Graco 04586 2115
Manual
-
Graco 9AU100
User Manual
-
Graco 19F547
User Manual
-
Graco 19F548
User Manual
-
Graco 19F552
User Manual
-
Graco 19F711
User Manual
-
Graco 20B432
User Manual
-
Graco 1AV
User Manual
-
Graco 04530 371
Manual
-
Graco 04586 711
Manual
-
Graco 00524 2101
Manual
-
Graco 00524 369
User Manual
-
Graco 03310 001
Manual
-
Graco 03706 101
Manual
-
Graco 01340 501
Manual
-
Graco 03706 201
Manual
-
Graco 06710 410
Manual
-
Graco 04522 401
Manual
-
Graco 04521 33F
Manual