Page 2 - Warning Symbol; Caution Symbol; CAUTION; WARNING; EQUIPMENT MISUSE HAZARD; Technical Data
2 307932 Table of Contents Warnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation/Maintenance 14 . . . . . . . . . . . . . . . . . . . . . . . . Parts 17 . . . . . . . ....
Page 3 - SKIN INJECTION HAZARD; MOVING PARTS HAZARD; Pressure Relief Procedure
3 307932 WARNING SKIN INJECTION HAZARD Spray from the gun, leaks or ruptured components can inject fluid into your body and cause extremelyserious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can alsocause serious injury. Fluid injected into the skin might loo...
Page 4 - FIRE AND EXPLOSION HAZARD; Grounding; TOXIC FLUID HAZARD
4 307932 WARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition andresult in a fire or explosion and serious injury. Ground the equipment and the object being sprayed. Refer to Grounding on page 5. If there is any static sparking...
Page 5 - Installation; General Information
5 307932 Installation General Information NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and theparts drawing. NOTE: Always use Genuine Graco Parts and Acces- sories, available from your Graco distributor. Refer tothe Product Data Sheet for your p...
Page 6 - Supplied Components; System Accessories
6 307932 Installation Supplied Components Refer to Fig. 2 for a typical installation of an airlesssystem. WARNING A red-handled bleed-type master air valve (14) anda fluid drain valve (7) are supplied in your system.These accessories help reduce the risk of seriousinjury, including fluid injection a...
Page 8 - Mounting Hole Layout
8 307932 Installation Models 245187 and 253697 (for AmbientTemperature Spray Applications) NOTE: Refer to page 10 to convert Pump Model 245187 or 253697 to a heated system. 1. Mount the pump wall bracket (2) 5 ft (1.5 m) abovethe floor. Be sure the wall is strong enough tosupport the weight of the p...
Page 9 - exactly
9 307932 Installation Models 245185 and 245186 (for HeatedTemperature Spray Applications) 1. Be sure the wall is strong enough to support theweight of the pump and accessories, heaters,hoses, fluid, and stress caused during operation. 2. Mount the pump wall bracket (2) 5 ft (1.5 m) abovethe floor. R...
Page 10 - Converting to a Heated System; Accessories for a Heated System; Installing Dual Heater Mounting Kit 222311; Pressure Relief
10 307932 Installation Converting to a Heated System To convert Model 245187 or 253697 to a heatedcirculating system, order the following parts. Theheaters are available in three voltages. Specify whichvoltage you desire. Two Viscon HP Fluid Heaters – Model 245848 (120 V, single-phase, 19.2 amp)– Mo...
Page 11 - COMPONENT RUPTURE HAZARD
11 307932 Installation 5. Screw the 3/4 npt street elbow (28*) into thepump’s fluid outlet. Assemble the nipple (27*),check valve (29*), coupling (30*), and swivel (50*)as shown in Fig. 6. The arrow on the check valvemust point down, toward the coupling. 6. Screw an elbow (32*) onto the lower heater...
Page 14 - Operation/Maintenance; Flush the Pump Before First Use
Model 254187 Shown Fig. 7 U 4414B 14 307932 Operation/Maintenance Pressure Relief Procedure WARNING SKIN INJECTION HAZARD The system pressure must be manuallyrelieved to prevent the system fromstarting or spraying accidentally. Fluid under high pressure can be injected through theskin and cause seri...
Page 15 - Starting and Adjusting the Pump; Heated Circulating Systems
15 307932 Operation/Maintenance Starting and Adjusting the Pump 1. Be sure the air regulator and bleed-type master airvalve are closed. NOTE: Do not install the spray tip yet! 2. Open the bleed-type master air valve. 3. Hold a metal part of the spray gun firmly to theside of a grounded metal pail an...
Page 16 - Shutdown and Care of the Pump; Flushing
16 307932 Operation/Maintenance Shutdown and Care of the Pump WARNING To reduce the risk of serious injury whenever youare instructed to relieve pressure, always follow the Pressure Relief Procedure on page 14. For overnight shutdown, stop the pump at the bottomof its stroke to prevent fluid from dr...
Page 17 - Parts
05364 1 2 7 4 10 9 3 5 6 25 24 12 20 45 4 See Detail at left. 4 5 15 16 17 8 18 14 19 47 22 AIR REGULATOR DETAIL 5 21 22 11 A A 53 52 54 17 307932 Parts Model 245187, 33:1, Series B Model 253697, 28:1, Series A RefNo. Part No. Description Qty 1 245117 33:1 BULLDOG PUMP (245187 only)See 309340 for pa...
Page 21 - Sound Pressure Levels
21 307932 Technical Data Category Data Maximum fluid working pressure Model 245187: 3300 psi (228 bar, 22.8 MPa) Models 245185, 245186: 3000 psi (207 bar, 20.7 MPa) Model 253697: 2800 psi (193 bar, 19.3 MPa) Maximum air input pressure Models 245187, 253697: 100 psi (7 bar, 700 kPa) Model 245185, 245...
Page 22 - Graco Standard Warranty; Graco Information
22 307932 Graco Standard Warranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on thedate of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco,Grac...