Page 2 - Warning Symbol; Caution Symbol; CAUTION; WARNING; SKIN INJECTION HAZARD
2 309407 Table of Contents Warnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maintenance...
Page 3 - FIRE AND EXPLOSION HAZARD; TOXIC FLUID HAZARD
3 309407 WARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames, or sparks can cause a hazardous condition andresult in a fire or explosion and serious injury. D Ground the equipment and the object being dispensed to. Refer to Grounding on page 5. D If there is any stati...
Page 4 - EQUIPMENT MISUSE HAZARD
4 309407 WARNING EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury. D This equipment is for professional use only. D Read all instruction manuals, tags, and labels before operating the equipment. D Use the equipment only for its i...
Page 5 - Installation; Mounting the Pump
5 309407 Installation NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and theparts drawing. NOTE: Always use Genuine Graco Parts and Accessories, available from your Graco distributor. Grounding WARNING FIRE AND EXPLOSION HAZARD Before operating th...
Page 6 - Typical Installation
6 309407 Installation Mount the pump to suit the type of installation planned.Very heavy lubricants may require an inductor plate.See page 16 for the mounting hole layout anddimensions Install the air line accessories in the approximate ordershown in the Typical Installation. Install a bleed-typemas...
Page 7 - Operation; Startup and Adjustment; Maintenance
7 309407 Operation WARNING D This pump is designed to be used ONLY inpumping non-corrosive and non-abrasive lubri-cants and greases. Any other use of this pumpcan cause unsafe operating conditions andresult in component rupture, fire, or explosion,which can can cause serious bodily injury,including ...
Page 8 - Troubleshooting
8 309407 Troubleshooting WARNING To reduce the risk of serious injury whenever youare instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7. Before servicing this equipment always make sure to Relieve the Pressure . Note: Check all possible problems and solutions befo...
Page 9 - Notes
Page 10 - Service
10 309407 Service TI2148A Fig. 3 12 11 6 25 15 2 31 3 14 4 30 165 7 8 9 10
Page 11 - Displacement Pump Repair; Disassembly; Reassembly
11 309407 Service Displacement Pump Repair WARNING To reduce the risk of serious injury whenever youare instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7. Before you start: D To reduce down time, be sure you have allnecessary repair parts available. D Repair Kit 2...
Page 12 - Check Valve Adjustment
12 309407 Service 12. Slide priming plate (9) (beveled edge up) onto priming rod (8). Screw nut (10) onto priming rodand tighten. 13. Reconnect the pump’s ground wire to a true earth ground. Check Valve Adjustment This pump has an adjustable piston ball check. To change the piston ball travel, loose...
Page 14 - Parts
14 309407 Parts TI2147A 1 13 12 3 4 14 15 35* 34* 36* 33* 20 36* 34* 35* 16 8 2 31 530 6 11 7 9 10 Packing, vee* Spacer*
Page 16 - Dimensions; Mounting Hole Layout
16 309407 Dimensions Priming Piston 6.5 in. (165 mm)Diameter 1” npt(f) FluidOutlet 28.5 in. 13.9 in. (724 mm) (353 mm) 14 .6 in. (371 mm) 1/2 npt(f)Air Inlet TI2146A Model 965124 Model 965129 37.3 in. (947.4 mm) Model 965124 Model 965129 50.8 in. 1290 mm) Mounting Hole Layout 06337 3 1/4” (82.6 mm) ...
Page 17 - Sound Pressure Level; Sound Power Level
17 309407 Technical Data Fluid pressure ratio 10:1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air pressure operating range 40–180 psi (0.3–1.2 MPa, 3–12.4 bar) . . . . . . . . . . . . ....
Page 18 - Graco Standard Warranty; Graco Information
18 309407 Graco Standard Warranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on thedate of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco,Grac...