Page 2 - Contents
2 3A0239F Contents Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Repair . . . . . . . . . . . . . . . . . . . . . . ...
Page 3 - Models; 00 V Power Requirements
Models 3A0239F 3 Models The Residual Current Device (RCD) must be rated at 300 mA if it is installed. Basic modules provide power to the control dispense system only. Fully loaded modules provide power to the control dispense system, four heat zones, and two feed tanks. See 400 V Power Requireme...
Page 4 - Warnings; WARNING
Warnings 4 3A0239F Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-tion point symbol aler ts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-s...
Page 5 - Troubleshooting
Troubleshooting 3A0239F 5 Troubleshooting Problem Cause Solution No power received from DC power supply. Defective power supply. Check circuit breaker. Check power supply. Replace power supply. No power to MCM, heat zones, or tanks. Circuit breaker is tripping. Check circuit breaker for tripping and...
Page 6 - Repair; Replace Power Supply
Repair 6 3A0239F Repair Replace Power Supply 1. Turn off system power. 2. Open electrical enclosure door. 3. Disconnect power supply (1a) wires from the filter (1c) and the electrical enclosure connector. 4. Remove nuts and washers that secure power supply to electrical enclosure. 5. Install new pow...
Page 7 - Electrical Schematics; 30V, 1 Phase, Basic HFR Module Schematic
Electrical Schematics 3A0239F 7 Electrical Schematics 230V, 1 Phase, Basic HFR Module Schematic
Page 8 - 30V, 1 Phase, Loaded HFR Module Schematic
Electrical Schematics 8 3A0239F 230V, 1 Phase, Loaded HFR Module Schematic
Page 9 - 30V, 3 Phase, Basic HFR Module Schematic
Electrical Schematics 3A0239F 9 230V, 3 Phase, Basic HFR Module Schematic
Page 10 - 30V, 3 Phase, Basic VRM Module Schematic
Electrical Schematics 10 3A0239F 230V, 3 Phase, Basic VRM Module Schematic
Page 11 - 30V, 3 Phase, Loaded HFR Module Schematic
Electrical Schematics 3A0239F 11 230V, 3 Phase, Loaded HFR Module Schematic
Page 12 - 30V, 3 Phase, Loaded VRM Module Schematic
Electrical Schematics 12 3A0239F 230V, 3 Phase, Loaded VRM Module Schematic
Page 13 - 00V, 3 Phase, Basic HFR Module Schematic
Electrical Schematics 3A0239F 13 400V, 3 Phase, Basic HFR Module Schematic
Page 14 - 00V, 3 Phase, Basic VRM Module Schematic
Electrical Schematics 14 3A0239F 400V, 3 Phase, Basic VRM Module Schematic
Page 15 - 00V, 3 Phase, Loaded HFR Module Schematic
Electrical Schematics 3A0239F 15 400V, 3 Phase, Loaded HFR Module Schematic
Page 16 - 00V, 3 Phase, Loaded VRM Module Schematic
Electrical Schematics 16 3A0239F 400V, 3 Phase, Loaded VRM Module Schematic
Page 17 - 30V, 3 Phase, Loaded VPM Module Schematic
Electrical Schematics 3A0239F 17 190 199 197 195 192 160 188 186 184 182 180 178 176 174 172 170 168 164 166 162 158 156 154 152 150 191 198 194 196 193 161 189 187 185 183 181 179 177 175 173 171 169 165 167 163 159 157 155 153 151 148 1L3 148 1L2 PRIMARY HT A VOLUME CB9 PG166 649 MISC A VOLUME CB6...
Page 20 - Parts; HFR Power Distribution Modules
Parts 20 3A0239F Parts HFR Power Distribution Modules r_24C686_3A0239_2b 400V, 3 Phase, Basic Module Shown r_24C688_3A0239_4a Circuit Breaker Detail for 400V, 3 Phase, Loaded Module 19 18, 48 56 4 11 8 5, 6 9 7 3 1 2 8 3 13 12 39 35 10 21 56 62 14 8 23 7 10 44 35 36 38 36 35 39 46 46 11 69
Page 21 - Parts Used on All HFR Modules
Parts 3A0239F 21 Parts Used on All HFR Modules Not shown. --- Not for sale. Replacement Danger and Warning labels, tags, and cards are available at no cost. r_24C680_3A0239_5a r_24C680_3A0239_6a 24 26 61 26 29 25 27 20 27 1c 1a Ref. Part Description Qty. 1 --- ENCLOSURE 1 1a 24D207 SUPPLY, power...
Page 22 - Parts that Vary by HFR Module
Parts 22 3A0239F Parts that Vary by HFR Module Use the following table to locate parts that vary by module. See Parts Used on All HFR Modules, page 21, for parts used on all HFR modules. Not shown. --- Not for sale. Ref. Description 230V, 1 phase, basic 230V, 1 phase, loaded 230V, 3 phase, basic 2...
Page 23 - VRM Power Distribution Modules
Parts 3A0239F 23 VRM Power Distribution Modules 400V, 3 Phase, Basic Module Shown r_24C687_3A0239_3a r_24C689_3A0239_7a Circuit Breaker Detail for 400V, 3 Phase, Loaded Module 19 18, 48 56 4 11 8 5, 6 23 7 3 1 2 8 3 13 12 39 35 10 21 56 57 14 23 7 10 44 35 36 38 36 35 39 46 46 11 21 9 8, 49, 50 55 3...
Page 24 - Parts Used on All VRM Modules
Parts 24 3A0239F Parts Used on All VRM Modules Not shown. --- Not for sale. Replacement Danger and Warning labels, tags, and cards are available at no cost. r_24C683_3A0239_9a r_24C683_3A0239_8a 26 63, 64, 65 27 26 25 29 27 28 20 24 20 1c 1a Ref. Part Description Qty. 1 --- ENCLOSURE 1 1a 24D207...
Page 25 - Parts that Vary by VRM Module
Parts 3A0239F 25 Parts that Vary by VRM Module Use the following table to locate parts that vary by module. See Parts Used on All VRM Modules, page 24, for parts used on all VRM modules. Not shown. Ref Description 230V,3 phase, basic 230V, 3 phase, loaded 400V, 3 phase, basic 400V, 3 phase, loaded...
Page 26 - VPM Power Distribution Modules
Parts 26 3A0239F VPM Power Distribution Modules 400V, 3 Phase, Basic Module Shown Circuit Breaker Detail for 400V, 3 Phase, Loaded Module 23 46 7 10, 47 39 35 44 37 36 35 39 18, 48 19 57 55 49, 50, 8 23 62 3 8 21 9 57 8 3 12 13 2 4 5, 6 8 7 1 69 14 ti18047a ti18046a
Page 28 - Parts Used on All VPM Modules
Parts 28 3A0239F Parts Used on All VPM Modules Not shown. --- Not for sale. Replacement Danger and Warning labels, tags, and cards are available at no cost. Parts that Vary by VPM Module Use the following table to locate parts that vary by module. See Parts Used on All VPM Modules, page 28, for ...
Page 30 - Graco Standard Warranty
Graco Standard Warranty 30 3A0239F Graco Standard Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any...