Page 2 - Warnings
Warnings 2 309935D Warnings The following are general warnings related to the setup, use, grounding, maintenance and repair of this equipment. Additional, more sepcific warnings may be found throughout the body of this manual where applicable. Symbols appearing in the body of the manual refer to the...
Page 3 - WARNING; EQUIPMENT MISUSE HAZARD
WARNING 309935D 3 WARNING EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury.• Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. Read Technical Data in all equipment manuals. • Use fluids and solvents that are compatible with equipme...
Page 4 - Mise en garde; MISE EN GARDE
Mise en garde 4 309935D Mise en garde Les mises en gardes suivantes sont des mises en garde de sécurité relatives à la configuration, utilisation, mise à la terre, maintenance et réparation de ce matériel. D’autres mises en garde plus spécifiques figurent dans ce manuel aux endroits concernés. Les s...
Page 6 - Advertencias; ADVERTENCIAS
Advertencias 6 309935D Advertencias A continuación se ofrecen advertencias en general relacionadas con la seguridad de la puesta en marcha, utilización, conexión a tierra, mantenimiento y reparación de este equipo. Además, puede encontrar advertencias adicionales a lo largo de este manual siempre qu...
Page 9 - Grounding / Mise à la terre / Conexión a tierra
309935D 9 Grounding / Mise à la terre / Conexión a tierra English Français Español The sprayer must be grounded. Grounding reduces the risk of static and electric shock by providing an escape wire for the electrical current due to static build up or in the event of a short circuit. Ce pulvérisateur ...
Page 10 - Ground
10 309935D Power Requirements Extension Cords • Do not modify plug! If it will not fit in outlet, have grounded outlet installed by a qualified electri-cian. Do not use an adapter. • 100-120V units require 100-120 VAC, 50/60 Hz, 11A, 1 phase. • 230V units require 230 VAC, 50/60 HZ, 7.5A, 1 phase. • ...
Page 11 - Pails; Seaux
309935D 11 Pails • Solvent and oil/based fluids: follow local code. Use only con-ductive metal pails, placed on a grounded surface such as concrete. • Do not place pail on a nonconduc-tive surface such as paper or card-board which interrupts grounding continuity. • Grounding a metal pail: connect a ...
Page 12 - Pressure Relief Procedure / Décompression / Descompresión; Pressure Relief; Décompression; Descompresión; Apague
Pressure Relief Procedure / Décompression / Descompresión 12 309935D Pressure Relief Procedure / Décompression / Descompresión Pressure Relief 1 Turn power OFF. Wait 7 seconds for power to dissipate. 2 Lock gun trigger safety. Remove guard and SwitchTip. 3 Turn pressure to lowest setting. Trigger gu...
Page 14 - Approximate Fill Level
Setup / Installation / Puesta en marcha 14 309935D 5 Check inlet strainer for clogs and debris. 6 Fill throat packing nut with TSL to prevent premature packing wear. Do this each time you spray. 7 Turn power OFF. 8 Plug power supply cord into a properly grounded electrical outlet. 5 Vérifier si la c...
Page 15 - Startup; Démarrage
Setup / Installation / Puesta en marcha 309935D 15 9 Turn prime valve down. 10 Place siphon tube set in grounded metal pail partially filled with flushing fluid. Attach ground wire to pail and to true earth ground. Do 1. - 5. of Startup to flush out storage oil shipped in sprayer. Use water to flush...
Page 16 - ON; MARCHE
Startup / Démarrage / Puesta en marcha 16 309935D Startup / Démarrage / Puesta en marcha 1 Turn pressure control to lowest pressure. 2 Turn power ON . 3 Increase pressure 1/2 to start motor and allow fluid to circulate through drain tube for 15 seconds; turn pressure down. 4 Turn prime valve horizon...
Page 20 - Operation Main Menu; Fonctionnement Menu principal; Menú principal de funcionamiento; psi
Digital Tracking System / Système de suivi numérique / Sistema de rastreo digital 20 309935D Digital Tracking System / Système de suivi numérique / Sistema de rastreo digital Operation Main Menu Short press moves to next display. Press and hold (5 seconds) changes units or resets data. 1 Turn pressu...
Page 23 - OR
Digital Tracking System / Système de suivi numérique / Sistema de rastreo digital 309935D 23 Secondary Menu Change Display Units: 5 Press and hold DTS button to clear error code to zero. 6 Short press DTS button. The W-DOG scrolls past and OFF is displayed. OFF is the default. To turn the W-DOG feat...
Page 27 - Warranty; POUR LES CLIENTS DE GRACO PARLANT FRANCAIS
Warranty 309935D 27 Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited...
Page 28 - TO PLACE AN ORDER; Minneapolis; International Offices:
Warranty 28 309935D TO PLACE AN ORDER , contact your Graco distributor, or call 1-800-690-2894 to identify the nearest distributor. All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make ch...