Page 2 - Contents; Warning; WARNING
Manual Conventions 2 309525G Contents Manual Conventions . . . . . . . . . . . . . . . . . . . . . . . . 2 Heated Hose Components . . . . . . . . . . . . . . . . . . . 4 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Operation . . . . . . . . . . . . . . . . . . . . ....
Page 4 - Heated Hose Components; Heated Hose Assembly; Single Hose Assemblies
Heated Hose Components 4 309525G Heated Hose Components You need the following parts to install the heated hose system on the Xtreme Mix proportioner. Heated Hose Kit 245866 The kit described in this manual, which includes all miscellaneous parts needed to assemble the system. Heated Hose Assembly O...
Page 5 - Fluid Heater
Heated Hose Components 309525G 5 Fluid Heater Order separately a VISCON HP heater that meets local electrical and hazardous location requirements. Hazardous Location Heaters Non-hazardous Location Heaters Part No. Series VAC (50/60 Hz single phase) / Watts / Amps Approvals 245848 A 120 / 2300 / 19.2...
Page 7 - Installation
Installation 309525G 7 Installation F IG . 1: Fluid and Air Line Connection Schematic 6 3, 7, 22, 25 10, 11, 15 24 10, 15, 23 12, 15 B 13, 15 14, 15 1 1 1 16 C 5 RED BLUE 14, 15 17 14, 15 C 14, 15 Resin Hose Catalyst Hose (optional installation)
Page 8 - Installing the Kit; Connecting Additional Hose Lengths
Installation 8 309525G Installing the Kit Refer to F IG . 1 and F IG . 2 1. Mount pump (16) on the Xtreme Mix cart (D) usingthe bracket (21), lockwashers (4), and nuts (2). 2. Mount VISCON HP heater (B-ordered separately)on the cart using screws and lockwashers (A) sup-plied with the heater, and the...
Page 10 - Operation
Operation 10 309525G Operation Refer to F IG . 2 1. Select fluid to use for heating circulation. • If ambient temperatures (storage or operating)are below 40° F (4.4° C), a 50% water and 50%antifreeze mixture is recommended. • If ambient temperatures are above 40° F (4.4°C), water alone is okay. 2. ...
Page 11 - Maintenance
Maintenance 309525G 11 Maintenance • Check reservoir tank fluid level daily. Add fluid asneeded. • Follow pump maintenance instructions in Husky 716manual. • Follow heater maintenance instructions in VISCONHP manual. Troubleshooting Related Manuals Refer to the following manuals for detailed equipme...
Page 12 - Parts
Parts 12 309525G Parts 3 7 22 17 6 D 2 15 14 20 19 1 15 12 B 10 15 8 15 13 11 9 8 A 21 16 2 4 14 15 1 1510 23 24 4 25
Page 14 - Technical Data
Technical Data 14 309525G Technical Data Maximum Working Pressure High Pressure Fluid Hose . . . . . . . . . . . . . . . . . . . . . See Heated Hose Assembly table, page 4 Heated Fluid Circulation Components . . . . . . . . . . . . 95 psi (0.6 MPa, 6.6 bar) Maximum Temperature Rating . . . . . . . ....
Page 15 - Heated Hose Replacement Parts; Accessory Scuff Jacket
Heated Hose Replacement Parts 309525G 15 Heated Hose Replacement Parts Order the quantity required for your hose. Accessory Scuff Jacket Use to cover and protect heated hose.85 ft. (25.9 m) 101 102 104 103 105 Ref.No. Part No. Description 101 117423 ELBOW; 1/2 npt(m) x 1/2” (13 mm) OD tube 102 11742...
Page 16 - Graco Standard Warranty; Graco Information
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. Original instructions. This manual contains English. MM 309525 Graco Headquarters: Minneapolis Int...