Page 2 - Warnings; WARNING
Warnings 2 309454D Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manua...
Page 3 - Common Terms
Warnings 309454D 3 Common Terms The following terms are shown on the Accu-Shot LCD display and used in this instruction manual. RESET BUTTON: when pressed, resets the Partial Delivery total to zero. CUMULATIVE TOTAL: non-resettable total. Display to show the cumulative amount of grease dispense. It ...
Page 4 - Installation
Installation 4 309454D Installation Key: A Fluid shut-off valve B Hose C Hose reel fluid inlet hose D Hose reel E Accu-Shot electronic grease meter F 2 in. swivel The installation shown in F IG . 1 is only a guide. The components shown are typical; however, it is not a com-plete system design. Conta...
Page 5 - Grounding; Installation Procedure
Installation 309454D 5 Grounding Refer to the user manuals for the pump and other sys-tem components, and ground the following: • Pump: follow the manufacturer’s recommendations. • Fluid hoses: use only grounded hoses. • Air compressor: follow the manufacturer’s recom-mendations. • Fluid supply cont...
Page 6 - Grease Dispenser Components
Installation 6 309454D 7. Apply thread sealant to the male threads of the hose fitting (f), thread the hose fitting into the fitting (2) of the Accu-Shot, and tighten firmly. (F IG . 2) NOTE: Let the sealant cure to the manufacturer’s rec- ommendations before the system is pressurized with grease. 8...
Page 7 - Operation; Before Dispensing Grease; Dispensing Grease; After Dispensing Grease
Operation 309454D 7 Operation Before Dispensing Grease The partial delivery meter (a) must read zero. If the meter indicates a valve other than zero, press the RESET button (b). (F IG . 4) NOTE: The partial delivery total cannot be zero-set dur- ing the dispensing process. Dispensing Grease 1. Pull ...
Page 8 - Maintenance; Battery Replacement; Cleaning the Metering Chamber
Maintenance 8 309454D Maintenance Battery Replacement Refer to F IG . 5 for the following instructions. The display will remain off after the batteries have been replaced. This is because the Accu-Shot is equipped with a system that prevents powering the electrical com-ponents during battery replace...
Page 9 - Adjusting the Operating Lever; Cleaning the Valve
Maintenance 309454D 9 Adjusting the Operating Lever Refer to F IG . 7 for the following instructions. The Accu-Shot valve operating lever (36) can be adjusted using the adjustment set screw (41) and check nut (40). The Accu-Shot is shipped with the lever already locked and set and therefore does not...
Page 10 - Troubleshooting
Troubleshooting 10 309454D NOTE: Use compressed air to clean these parts. Grease all par ts before reassembly. Avoid pinching the o-rings during reassembly. 9. Refit the following components in the valve seat in the order given below, being careful not to damage them. • The retaining ring (9) and o-...
Page 11 - Parts
Parts 309454D 11 Parts Torque to 4 to 6 in-lb (0.45 to 0.68 N.m) 1 1 1 2 3 4 45 5 6 7 40 39 41 38 37 36 35 31 32 34 24 25 26 22 21 17 16 15 14 13 12 11 9 10 1
Page 13 - Technical Data
Technical Data 309454D 13 Technical Data . Dimensions Accu-Shot ™ Electronic Grease Meter US Metric Maximum fluid working pressure 5000 psi 34.5 MPa, 345 bar Storage temperature (range) -4 to 158°F -20 to 70°C Storage humidity (maximum) 95 (%RU) Operating Temperature (maximum) 140°F 60°C Metering sy...
Page 14 - Graco Standard Warranty; Graco Information
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. For patent information, see www.graco.com/patents. Original instructions. This manual contains Eng...