2 308-807 Table of Contents Warnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Service 6 ...
Page 3 - EQUIPMENT MISUSE HAZARD; FIRE AND EXPLOSION HAZARD
3 308-807 WARNING EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury. D This equipment is for professional use only. D Read all instruction manuals, tags, and labels before operating the equipment. D Use the equipment only for its ...
Page 4 - Installation; Grounding
4 308-807 Installation Grounding WARNING FIRE AND EXPLOSION HAZARDBefore operating the pump, ground thesystem as explained below. Also readthe section FIRE AND EXPLOSION HAZARD on page 3. 1. Pump: use a ground wire and clamp as shown inyour separate pump manual. 2. Fluid hoses: use only electrically...
Page 5 - Operation; Pressure Relief Procedure; Flow Rate Adjustment; Lubrication and Care
5 308-807 Operation Pressure Relief Procedure WARNING INJECTION HAZARDThe system pressure must be manuallyrelieved to prevent the system fromstarting or dispensing accidentally. Fluid under high pressure can be injected through theskin and cause serious injury. To reduce the risk ofan injury from in...
Page 6 - Service; Disassembly; Reassembly
6 308-807 Service NOTE: Repair kits are available. See page 7 for thekits for your gun model. For the best results, use allthe new parts in the kit. Kit parts are marked with anasterisk, for example (2*). NOTE: See the Parts Drawing on page 7 whendisassembling and reassembling the gun. Disassembly W...
Page 7 - Parts; Repair Kits
7 308-807 Parts 7904A 6 3 A 12 1 10 5 11 2 B 1 2 Grease the needle o-rings. Torque to 18–22 in-lb (2.03–2.46 N S m). 1 2 Models 240–199 and 240–200 Ref No. Part No. Description Qty 1 240–208 BODY, Flow Gun 1 2* 240–201 NEEDLE, 3/16 ballModel 240–199 only 1 240–202 NEEDLE, taperedModel 240–200 only 1...
Page 8 - Technical Data
8 308-807 Technical Data Category Data Maximum working pressure 3400 psi (23.4 MPa, 234 bar) Maximum temperature 120 _ F (49 _ C) Flow rate at 2000 psi (14 MPa, 138 bar)* Model 240–199: 158 oz/min (4.5 kg/min)Model 240–200: 154 oz/min (4.4 kg/min) Outlet port size 1/4 npt(f) and flange Inlet port si...
Page 9 - Notes
Page 13 - Parts Change Notice; Other Changes
13 308-807 3X8–807 Rev. C Supersedes Rev. B Parts Change Notice Some parts in Rev. B of manual 308–807 have changed but have not yet been changed in theinstruction manual. Please note the changes below and mark them in your manual or keep thissheet with your manual. Assembly No. SeriesLetterChange P...