Page 2 - Warning Symbol; Caution Symbol; CAUTION; WARNING; EQUIPMENT MISUSE HAZARD; MOVING PARTS HAZARD
2 308771 Table of Contents Warnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Parts 10 . ...
Page 3 - PRESSURIZED EQUIPMENT HAZARD; FIRE, EXPLOSION, AND ELECTRIC SHOCK HAZARD; TOXIC FLUID HAZARD
308771 3 WARNING PRESSURIZED EQUIPMENT HAZARD Spray from the gun, hose leaks, or ruptured components can splash fluid in the eyes or on the skinand cause serious injury. D Do not point the gun at anyone or at any part of the body. D Do not stop or deflect leaks with your hand, body, glove or rag. D ...
Page 4 - Installation; General Information
4 308771 Installation General Information NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and theparts drawing. Prepare the Operator All persons who operate the equipment must betrained in the safe, efficient operation of all systemcomponents as we...
Page 6 - Connect the Fluid Lines
6 308771 Installation Connect the Fluid Lines Connect a 1 to 3 ft (0.3 to 0.9 m) hose to the tee at theoutlet of the fluid filter, to isolate the pump module fromthe main fluid line. Connect the other end of the hoseto the main fluid line. Grounding WARNING FIRE, EXPLOSION, AND ELECTRIC SHOCK HAZARD...
Page 7 - Operation; Preventive Maintenance Schedule
308771 7 Operation Pressure Relief Procedure WARNING PRESSURIZED EQUIPMENT HAZARD The system pressure must be manually relieved toprevent the system from starting or spraying acci-dentally. To reduce the risk of an injury from acci-dental spray from the gun, splashing fluid, ormoving parts, follow t...
Page 8 - Heater Operation; Adjust the Spray Pattern
8 308771 Operation Heater Operation Before operating the heater, read the heater instructionmanual 309524 which is supplied. Prime the Pump 1. Disconnect the electric power to the heater beforepriming the pump. 2. Open the fluid shutoff valve (L). 3. Open the back pressure regulator (M). Turn the3-w...
Page 10 - Parts
10 308771 Parts 1 Pump Module. Not included. 1 Supply Module. Not included. 2 1 2 3 4 5 2 1 PartofRef.No. Not used with Pump Module 232078. 3 3 7782C 6 7 Ref.No. Description Module239850 Module239851 Module239852 Module241883 Qty 1 HEATER, fluid, 120V; see manual 309524 245848 1 HEATER, fluid, 240V;...
Page 11 - Mounting Hole Layout
308771 11 Technical Data Category Data Maximum fluid working pressure 300 psi (2.1 MPa, 21 bar) Maximum operating temperature 150 _ F (66 _ C) Maximum heater voltage andamperage Part No. 239850: 120 VAC, 19.2 Ampere Part No. 241883: 200 VAC, 20.0 Ampere Part No. 239851 and 239852: 240 VAC, 16.7 Ampe...
Page 12 - Graco Standard Warranty; Graco Information
12 308771 Graco Standard Warranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on thedate of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limit...