Page 2 - Symbols; Warning Symbol; Caution Symbol; CAUTION; EQUIPMENT MISUSE HAZARD; WARNING; WARNING
2 308687 Symbols Warning Symbol WARNING This symbol alerts you to the possibility of seriousinjury or death if you do not follow the instructions. Caution Symbol CAUTION This symbol alerts you to the possibility of damage toor destruction of equipment if you do not follow theinstructions. EQUIPMENT ...
Page 3 - FIRE AND EXPLOSION HAZARD; SKIN INJECTION HAZARD
3 308687 FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames, or sparks can cause a hazardous condition andresult in a fire or explosion and serious injury. D Be sure the entire fluid system is properly grounded. Refer to your pump instruction manual forcomplete details. See ...
Page 4 - Installation; KEY
4 308687 Installation These meters must be installed in-line as part of a dispense system as shown in Fig. 1. The typical installationshown is only a guide for selecting and installing an in-line meter; it is not an actual system design. Contact yourGraco distributor for assistance in designing a sy...
Page 5 - Grounding; Factory Settings
5 308687 Installation Grounding The use of PTFE tape on threaded connections tothe meter is not recommended, because it couldinterrupt the grounding continuity of the system.Standard pipe thread compound is recommended. CAUTION Proper grounding is an essential part of maintaining asafe system. To re...
Page 6 - Operation
6 308687 Operation Sleep Mode The meter automatically shuts down the display afterone minute of non-use. Activation Mode There are two ways to activate the display: D Press any button on the keypad to wake up thedigital display. The amount displayed is the valuestored when the meter went into sleep ...
Page 7 - Changing the Measurement Units and Calibration Factor
7 308687 Operation Changing the Measurement Units and Calibration Factor NOTE: A one liter Weights and Measures ap-proved container is required for calibration. This meter is factory calibrated to dispense 10W–30motor oil at 70 _ F (21 _ C) at 2.0 gpm (7.6 lpm) and is acceptably accurate for most co...
Page 8 - Service; Replacing the Battery
8 308687 Service Replacing the Battery FIRE AND EXPLOSION HAZARD Only replace the battery in anon-hazardous location, away fromflammable fluids or fumes. You must use one of the following battery types: D Duracell R MN1604, PC1604 D Eveready R EN22, 522 Use of any batteries other than those specifie...
Page 9 - Replacing the Electronic Control
9 308687 Service 7262B Fig. 5 1 4 metalcover 3 Replacing the Electronic Control Follow this procedure to replace the electronic control: 1. Relieve the pressure. WARNING To reduce the risk of serious injury, whenever youare instructed to relieve pressure, always follow thePressure Relief Procedure o...
Page 10 - Troubleshooting; Pressure Relief Procedure; Parts
10 308687 Troubleshooting PRESSURIZED EQUIPMENT HAZARDThe equipment stays pressurized until pressure ismanually relieved. To reduce the risk of seriousinjury from pressurized fluid, accidental spray fromthe dispenser, or splashing fluid, follow the Pres-sure Relief Procedure whenever you D Are instr...
Page 11 - Accessories; Technical Data
11 308687 Accessories Shutoff valve 108458 Install upstream from the meter. Shuts off fluid supplyfrom the pump. 1/2–14 npt(f) both ends. Thermal Relief Kit 235998 (1/2–14 npt(m) x 1/2–14 npt(f) Install downstream from the pump. Strainer Kit 239876 (includes strainer and o-ring) Install the strainer...