Page 2 - Warning Symbol; Caution Symbol; CAUTION; WARNING; INJECTION HAZARD
308–287 Table of Contents Warnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maintenance 7 ...
Page 3 - EQUIPMENT MISUSE HAZARD
3 308–287 WARNING INSTRUCTIONS EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture, malfunction, or start unexpectedly and resultin a serious injury. D This equipment is for professional use only. D Read all the instruction manuals, tags, and labels before operating the equip...
Page 4 - Installation; Installing the System
4 308–287 Installation A B 2 C D E G H B 1 C D E F J K KEY A Air Supply Line B Bleed-Type Air Supply Line Shut-off Valve (required) C Air Line Filter D Air Line Lubricator E Air Line Regulator F Pump G Fiber Optic Cable H Flow Meter J Fluid Supply Line K Fluid Supply L Main Power Switch M Pendant N ...
Page 5 - Check the Electrical Grounding
5 308–287 Installation Fig. 1 KEY A Tubing, 1/4” OD B Nut (nylon) C Ferrule, back (nylon) D Ferrule, front (nylon) E Air Inlet Fitting F Electrical Chassis G Fiber Optic Cables H Gear Housing Assy. J Nut (aluminum) K Ferrule, back (aluminum) L Ferrule, front (aluminum) J A C D E F H G Flow Indicator...
Page 6 - Pressure Relief Procedure; System Operating Checklist; Operation
6 308–287 Operation Pressure Relief Procedure WARNING INJECTION HAZARDFluid under high pressure can be in-jected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or movingparts, follow the Pressure Relief Procedurewhenever you: are instructe...
Page 7 - Maintenance; Flushing the Meter
7 308–287 Maintenance CAUTION Do not immerse the meter in solvent. Solvent coulddamage the meter’s electrical components. 1. Clean the fluid and air line filters daily. 2. Clean the outside of the meter with a soft clothdampened in a compatible solvent as needed. 3. Flush the fluid supply line and m...
Page 8 - Troubleshooting
8 308–287 Troubleshooting WARNING Installing and servicing this equipment requiresaccess to parts that may cause electric shock orother serious injury if the work is not performedproperly. Do not install or service this equipmentunless you are trained and qualified. To reduce the risk of serious inj...
Page 9 - Service; Replacing the Turbine Alternator
9 308–287 Service WARNING Installing and servicing this equipment requiresaccess to parts that may cause electric shock orother serious injury if the work is not performedproperly. Do not install or service this equipmentunless you are trained and qualified. To reduce the risk of serious injury when...
Page 10 - Replacing Worn Bearings
10 308–287 Service Replacing Worn Bearings A repair kit is available to service the bearings. Anasterisk after the description or reference letter indi-cates a part included with the repair kit. See page 11to order the proper kit for your meter model. CAUTION This is a close-tolerance device. It wil...
Page 11 - Removing Bearings; Parts
11 308–287 Service Fig. 6 Fig. 7 Removing Bearings Installing Bearings ÉÉ ÉÉ ÉÉ ÉÉ ÉÉ ÉÉ 0968 ÉÉÉ ÉÉÉ ÉÉÉ ÉÉÉ ÉÉÉ ÉÉÉ 0969 KEY L Gear Assembly T* Bearing ToolV* Bearings and SpacersW Support *T V W L KEY L Gear P* BearingR* Inner SpacerS* Outer SpacerT* Bearing ToolU Flat Surface *T *S L R* P* P* U ...
Page 14 - Accessories; Fiber Optic Cables; Fluid Manifold
14 308–287 Accessories Fiber Optic Cables Fiber Optic Cable AssemblyFor connection between the controller and flow meter. PART NO. LENGTH 224–690 6 ft (1.8 m) 224–691 15 ft (5 m) 224–692 25 ft (8 m) 224–693 36 ft (11 m) 224–694 50 ft (15 m) 224–695 75 ft (23 m) 224–696 100 ft (30.5 m) Fiber Optic Ca...
Page 15 - Manual Change Summary
15 308–287 Dimensions 01847 DIM. B DIM. A DIM. C Part No. Dim. A Dim. B Dim. C 235–402 4.25 in (108 mm) 4.10 in. (104 mm) 4.44 in. (113 mm) 235–403 4.25 in (108 mm) 4.25 in. (108 mm) 4.50 in. (114 mm) Technical Data Category Data Maximum Working Fluid Pressure 2800 psi (19.6 MPa, 196 bar) Maximum Wo...
Page 16 - The Graco Warranty; Graco Phone Number
16 308–287 The Graco Warranty Graco warrants all equipment listed in this manual which is manufactured by Graco and bearing its name to be free from defects inmaterial and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception ofany s...