Page 2 - Symbols; Warning Symbol; Caution Symbol; CAUTION; WARNING; SKIN INJECTION HAZARD; TOXIC FLUID HAZARD
2 308253 Symbols Warning Symbol WARNING This symbol alerts you to the possibility of seriousinjury or death if you do not follow the instructions. Caution Symbol CAUTION This symbol alerts you to the possibility of damage toor destruction of equipment if you do not follow theinstructions. WARNING SK...
Page 3 - FIRE AND EXPLOSION HAZARD; EQUIPMENT MISUSE HAZARD
308253 3 WARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor air ventilation, open flames, or sparks can cause a hazardous condition andresult in a fire or explosion and serious injury. Ground the equipment and the object being sprayed. See Ground the System on page 5. Provide fresh air venti...
Page 5 - Installation
308253 5 Installation Ground the System WARNING FIRE AND EXPLOSION HAZARD To reduce the risk of a fire, explosion,and serious injury, proper electricalgrounding of every part of your system isessential. Read the warning section, FIRE AND EXPLOSION HAZARD , on page 3 and follow the groundinginstructi...
Page 6 - Operation; Gun Trigger Safety
6 308253 Operation Pressure Relief Procedure WARNING SKIN INJECTION HAZARD The system pressure must be manuallyrelieved to prevent the system fromstarting or spraying accidentally. Fluid under high pressure can be injected through theskin and cause a serious injury. To reduce the riskof an injury fr...
Page 7 - Dispensing; Flushing Safety
308253 7 Operation Dispensing 1. Start the fluid supply pump. 2. The fluid flow rate is controlled at the pump. Adjustthe pump pressure to obtain the desired flow rate.It is recommended that you use the lowest pres-sure necessary to dispense the fluid. The pressureadjustment will depend on the hose ...
Page 8 - Service
8 308253 Service WARNING SKIN INJECTION HAZARD To reduce the risk of a serious injury,including fluid injection, Follow the Pressure Relief Procedure on page 6 when you stop dispensing, before servicingthe gun, and whenever you are instructed torelieve the pressure. After adjusting or servicing the ...
Page 9 - Adjusting the Valve; Adjusting the Spring Tension
308253 9 Service Adjusting the Valve The trigger travel and corresponding valve opening arefactory set to 1 inch (25.4 mm). To adjust this setting,follow the procedure below. WARNING SKIN INJECTION HAZARD To reduce the risk of a serious injury,including fluid injection, follow the Pres- sure Relief ...
Page 10 - Valve Stem and Seal Service
10 308253 Service Valve Stem and Seal Service If fluid leaks past the v-block seal (3), the v-block sealor valve stem (24) may be worn or damaged. Toreplace the seal or valve stem, follow the procedurebelow. WARNING SKIN INJECTION HAZARD To reduce the risk of a serious injury,including fluid injecti...
Page 14 - Parts; Pistol Grip Flow Gun
14 308253 Parts Models 235627 and 237607 Pistol Grip Flow Gun 22 * 26 * 5 * 24 21 4 28 27 * 3 * 1 20 7 2 17 8 29 15 9 14 6 19 * 8 * 13 35 34 05446
Page 22 - Graco Standard Warranty; Graco Phone Number; GRACO INC. AND SUBSIDIARIES
22 308253 Graco Standard Warranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on thedate of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limit...