Page 2 - Symbols; Warning Symbol; Caution Symbol; CAUTION; WARNING; EQUIPMENT MISUSE HAZARD
2 307985 Symbols Warning Symbol WARNING This symbol alerts you to the possibility of seriousinjury or death if you do not follow the instructions. Caution Symbol CAUTION This symbol alerts you to the possibility of damage toor destruction of equipment if you do not follow theinstructions. WARNING EQ...
Page 3 - FIRE AND EXPLOSION HAZARD; TOXIC FLUID HAZARD
307985 3 WARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition andresult in a fire or explosion and serious injury. D Ground the equipment and the object being sprayed. Refer to Grounding on page 5. D If there is any static spar...
Page 4 - Notes
Page 5 - Installation; General Information; Mounting the Pump
307985 5 Installation General Information NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and theparts drawing. NOTE: Always use Genuine Graco Parts and Acces- sories, available from your Graco distributor. If yousupply your own accessories, be sur...
Page 8 - Operation; Packing Nut; Flush the Pump Before First Use
8 307985 Operation Pressure Relief Procedure WARNING PRESSURIZED EQUIPMENT HAZARD The system pressure must be manually relieved toprevent the system from starting or spraying acci-dentally. To reduce the risk of an injury from acci-dental spray from the gun, splashing fluid, ormoving parts, follow t...
Page 9 - Prime the Pump
307985 9 Operation Prime the Pump 1. See Fig. 2. Remove the spray nozzle from thegun. See the gun instruction manual. 2. Close all bleed-type air valves (A, N). 3. Close the pump air filter/regulator (B). 4. Close the fluid drain valve (D). 5. Check that all fittings throughout the system aretighten...
Page 11 - Maintenance; Shutdown and Care of the Pump; Flushing; Fluid Piston and Intake Valve Adjustment
307985 11 Maintenance Shutdown and Care of the Pump WARNING To reduce the risk of serious injury whenever youare instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. For overnight shutdown, stop the pump at the bottomof its stroke to prevent fluid from drying on the...
Page 12 - Troubleshooting
12 307985 Troubleshooting WARNING To reduce the risk of serious injury whenever youare instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. 1. Relieve the pressure. 2. Check all possible problems and solutions before disassembling pump. Problem Cause Solution Pump f...
Page 13 - Service; Disconnecting the Displacement Pump; Reconnecting the Displacement Pump
307985 13 Service Disconnecting the Displacement Pump NOTE: For displacement pump repair instructions, refer to the separate displacement pump manual307983, supplied. WARNING To reduce the risk of serious injury whenever youare instructed to relieve pressure, always follow the Pressure Relief Proced...
Page 14 - Parts
14 307985 Parts Model 223185, Series C 2:1 Ratio Monark Pump, 55 Gallon (200 Liter) Drum Size; UHMWPE and Leather Packed Ref Part No. No. Description Qty 1 206955 AIR MOTOR, MonarkSee 307043 for parts 1 3 223177 PUMP, displacement;used on Model 223185See 307983 for parts 1 4 191611 ROD, connecting;1...
Page 15 - :1 Ratio Monark Pump, Stubby Size UHMWPE and Leather Packed
307985 15 Parts Model 223186, Series C 2:1 Ratio Monark Pump, Stubby Size; UHMWPE and Leather Packed Ref Part No. No. Description Qty 1 206955 AIR MOTOR, MonarkSee 307043 for parts 1 3 223177 PUMP, displacement;used on Model 223186See 307983 for parts 1 4 191736 ROD, connecting;6.98 in. (177.3 mm) l...
Page 18 - Graco Standard Warranty; Graco Information
18 307985 Graco Standard Warranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on thedate of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco,Grac...