Page 2 - Warnings; WARNING
Warnings 2 311937G Warnings The following Warnings are for the setup, use, grounding, maintenance and repair of this equipment. Theexclamation point symbol alerts you to a general warning and hazard symbols refer to procedure-specific risks. Referback to these Warnings. Additional, product-specific ...
Page 4 - Gun Trigger Lock; Connect Gun to Sprayer; Operation
Warnings 4 311937G Pressure Relief Procedure Follow this Pressure Relief Procedure whenever instructed to relieve pressure, stop spraying, check or service equipment,or install or clean spray tip.1. Lock trigger. Turn OFF power and turn pressure control tolowest pressure setting. 2. Unlock trigger. ...
Page 5 - Clearing a Clog; Maintenance; Flushing and Cleaning
Warnings 311937G 5 Clearing a Clog 1. Relieve pressure . Lock trigger (1a). 2. Rotate tip (33) 180°. Unlock trigger (1a). Trigger gun intopail or onto ground to remove clog. 3. Lock trigger (1a). Rotate tip (33) 180° back to sprayposition. Spraying Refer to your Sprayer Instruction manual. The follo...
Page 6 - Repair
Warnings 6 311937G 14. If the diffuser (5) was removed, trigger the gun while you reinstall the diffuser with the gun tool (30). Tighten thediffuser securely to obtain a good seal. Torque to 155-165in-lb (18-19 N.m). When properly tightened, the flange willbottom out on the gun. 15. Install tip (33)...
Page 7 - Reassembly; Tranlated Manuals
Warnings 311937G 7 Fluid Tube Replacement (16) 1. Remove the air inlet fitting(17) using the gun tool (30)and remove the screw (20)using a 3/16 in. hex wrench. 2. Unscrew the fluid inlet fitting(25). Remove and clean orreplace the inline fluid filter(24). 3. Unscrew fluid tube connector(16a) from fl...
Page 8 - Parts
Parts 8 311937G Parts ▲ Replacement Danger and Warning labels, tags, and cards are available at no cost. ◆ Included in Needle/Seat Repair Kit 255160 (purchase separately) † Included in RAC Guard Kit 288839 *Included in Seal Repair Kit 249422 (purchase separately) ‡ If you want to remove the filter, ...
Page 9 - Technical Data
Technical Data 311937G 9 Technical Data *All readings were taken with fan valve fully closed, (full fan size) at 20 psi (140 kPa, 1.4 bar) and 100 psi (0.7 kPa, 7bar) and at the assumed operator position. Sound Power tested to ISO 9614-2. Maximum Working Fluid Pressure..................................
Page 10 - Graco Standard Warranty; Graco Information
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. For patent information, see www.graco.com/patents 2ULJLQDOLQVWUXFWLRQV This manual contains Englis...