Page 2 - Warnings; Grounding Instructions; WARNING
Warnings 2 332161A Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual...
Page 5 - Component Identification
Component Identification 332161A 5 Component Identification A B C D E F H J K M N S P T R A Pressure Control B ON/OFF switch C Hour Meter D Power Cord E Fluid Outlet F Prime Valve H Pump J Suction Hose K Drain Hose M Fluid Hose N Gun P Tip R Guard S Trigger Safety Lock T Serial Number ID Label
Page 6 - Pressure Relief Procedure
Pressure Relief Procedure 6 332161A Pressure Relief Procedure Follow the Pressure Relief Procedure whenever you see this symbol. 1. Turn pressure control to lowest pressure. 2. Hold gun against side of grounded metal flushing pail. Trigger gun to relieve pressure. 3. Turn prime valve down. If you su...
Page 7 - Grounding; Power Requirements
Grounding 332161A 7 Grounding Air and fluid hoses: use only electrically conductive hoses with a maximum of 500 ft. (150 m) combined hose length to ensure grounding continuity. Check elec-trical resistance of hoses. If total resistance to ground exceeds 29 megohms, replace hose immediately. Spray gu...
Page 8 - Setup
Setup 8 332161A Setup 1. Connect Graco airless hose to sprayer. Tighten securely. 2. Connect other end of hose to gun. 3. Tighten securely. 4. Remove tip guard. 5. Check inlet strainer for clogs and debris. 6. Fill throat packing nut with TSL to prevent premature packing wear. Do this each time you ...
Page 9 - Startup
Startup 332161A 9 Startup 1. Turn pressure control to lowest pressure. 2. Turn power ON . 3. Increase pressure 1/4 turn to start motor. Allow fluid to circulate through drain tube for 15 seconds. 4. Turn prime valve horizontal.Take spray gun trigger safety OFF. 5. Hold gun against grounded metal flu...
Page 10 - Spray Test Pattern
Startup 10 332161A Spray Test Pattern 1. Spray test pattern. Adjust pressure to eliminate heavy edges. 2. Use smaller tip size if pressure adjustment cannot eliminate heavy edges. 3. Hold gun perpendicular, 10-12 in. from surface. Spray back and forth; overlap by 50%. 4. Trigger gun before moving. R...
Page 11 - Cleanup
Cleanup 332161A 11 Cleanup 1. Perform Relieve Pressure Procedure , page 6. 2. Remove guard and Spray Tip. For additional infor-mation, see gun manual. 3. Remove siphon tube set from paint. Wipe excess paint off outside of tubes. 4. Place siphon tube in flushing fluid. Use water for water base paint ...
Page 12 - Power Flush
Cleanup 12 332161A 11. Turn pressure control knob all the way down and power switch OFF. Unplug sprayer. 12. Remove filter from gun if installed. Clean and inspect. Install filter. See gun manual. 13. If flushing with water, flush again with mineral spirits or Pump Armor to leave a protective coatin...
Page 15 - Technical Data
Technical Data 332161A 15 Technical Data *Measured 3 feet (1 meter) from equipment. Power requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100/120V AC, 60 hz, 11A, 1 phaseGenerator required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3000 w minimumMaximum workin...
Page 16 - Graco Standard Warranty
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. For patent information, see www.graco.com/patents. Original instructions. This manual contains Eng...