Page 2 - Warning Symbol; Caution Symbol; CAUTION; WARNING; EQUIPMENT MISUSE HAZARD
2 307400 Table of Contents Warnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Troubleshoo...
Page 3 - INJECTION HAZARD; MOVING PARTS HAZARD
3 307400 WARNING INJECTION HAZARD Spray from the gun, leaks or ruptured components can inject fluid into your body and cause extremelyserious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can alsocause serious injury. D Fluid injected into the skin is a serious...
Page 4 - FIRE AND EXPLOSION HAZARD; TOXIC FLUID HAZARD; REACTIVE CHEMICALS HAZARD
4 307400 WARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and re-sult in a fire or explosion and serious injury. D Ground the equipment and the object being sprayed. Follow the grounding instructions onpage 5. D If there is...
Page 5 - Grounding; Installation
5 307400 Installation Grounding Proper grounding is an essential part of maintaining asafe system. To reduce the risk of static sparking, ground the pump.Check your local electrical code for detailed groundinginstructions for your area and type of equipment. Besure to ground all of this equipment: 1...
Page 6 - Operation; Flushing Procedure
6 307400 Operation Start-up The mixer manifold was tested in oil, which was left into protect the manifold. Before operating, thoroughlyflush the manifold to prevent contamination of thefluids. Flushing Procedure CAUTION Be sure to label all fluid path parts “component A” or“component B” when disass...
Page 7 - Dispensing
7 307400 Operation Be sure all fluid is thoroughly flushed from the hoseafter each use. Disassemble all other dispensing equipment, as nec-essary, and clean thoroughly. CAUTION To prevent fluid from setting up in the dispensingequipment, flush the system frequently. Be surethere is adequate solvent ...
Page 8 - Troubleshooting
8 307400 Operation Pressure Relief Procedure WARNING INJECTION HAZARD The system pressure must be manuallyrelieved to prevent the system fromstarting or spraying accidentally. Fluid under high pressure can be injected through theskin and cause serious injury. To reduce the risk ofan injury from inje...
Page 9 - Service; Manifold Repair; Ball Valve Repair
9 307400 Service Manifold Repair (See Page 10. ) WARNING To reduce the risk of serious injury whenever youare instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. Note: Repair kits are available for the manifold. Parts included in the kits are indicated with a †, fo...
Page 10 - Parts
10 307400 Parts 11 Ref No.13Ball Valve 215622, Series BLow Volume Ref No.24Ball Valve 215623, Series BHigh Volume 18* 22 15* 27 29 31 30 28 34‡ 33‡ 32‡ 33‡ 23 26 Torque twice to 60–70 in-lb.(6.7–7.9 N S m) 05769 05768 14 20 *17 21 *17 *16 19* 22 15* 19* 25 28 26 30 4† 3† 12 2 1 8 9† 6† 7 6† 9† 8 5 1...
Page 11 - Kits for Series A Manifolds
11 307400 Parts Models 215625 and 215626, Series C RefNo. Part No. Description Qty. 1 100721 PLUG, internal hex; 1/4; 1/4 npt 2 2 104472 CAPSCREW, hex hd;10–32 x 1–1/2 12 3† 105694 SEAL, shaft; SST and PTFE R 2 4† 177019 RING, back-up; Delrin R 2 5 177021 NIPPLE, pipe, hex; 1/4 npt 1 6† 177022 SEAT,...
Page 14 - Dimensions
14 307400 Dimensions Model 215625 Model 215626 Model 241692 A Overall Length 5.0 in (127 mm) 5.5 in (140 mm) 5.5 in (140 mm) B Overall Height 5.375 in. (136 mm) 6.25 in (159 mm) 19.85 in (504 mm) C Overall Width 1.375 in (35 mm) 1.25 in (32 mm) 1.25 in (32 mm) D Fluid Inlets 1/4 npt(m) 3/8 npt(m) 3/...
Page 15 - Notes
Page 16 - Graco Standard Warranty; Graco Information
16 307400 Graco Standard Warranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on thedate of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limit...