Page 2 - Warning Symbol; Caution Symbol; CAUTION; WARNING; EQUIPMENT MISUSE HAZARD
2 307043 Table of Contents Warnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air Motor Service 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Parts Drawings ...
Page 3 - SKIN INJECTION HAZARD
3 307043 WARNING SKIN INJECTION HAZARD Spray from the gun/dispensing valve, leaks or ruptured components can inject fluid into your body andcause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on theskin can also cause serious injury. D Fluid injected into...
Page 4 - FIRE AND EXPLOSION HAZARD; TOXIC FLUID HAZARD
4 307043 WARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition andresult in a fire or explosion and serious injury. D Ground the equipment and the object being sprayed. Refer to Grounding on page 5. D If there is any static spar...
Page 5 - Installation; Grounding
5 307043 Installation Grounding WARNING FIRE AND EXPLOSION HAZARDBefore operating the pump, ground thesystem as explained below. Also readthe section FIRE AND EXPLOSIONHAZARD on page 4. Proper grounding is an essential part of maintaining asafe system. To reduce the risk of static sparking, ground t...
Page 6 - Air Motor Service; Pressure Relief Procedure; Before You Start
6 307043 Air Motor Service Pressure Relief Procedure WARNING SKIN INJECTION HAZARDThe system pressure must be manuallyrelieved to prevent the system fromstarting or spraying/dispensing acciden- tally. Fluid under high pressure can be injectedthrough the skin and cause serious injury. To re-duce the ...
Page 8 - Reassembly
8 307043 Air Motor Service 13. Straighten the lockwires (L*) and remove them from the upper valve nuts (J*). Screw the uppervalve nuts off. Remove the trip rod yoke (O),actuator (V), and trip rod (C). 14. Unscrew the bottom valve nuts (K*), and remove the poppets (N*). Make sure the valve bar spring...
Page 10 - Parts
6 *12 13 9* 10* 11 n 31 n 14 *15 2 21 20 5 18 32 34 33 05704 n 3 n 7 25 24* 8* 9* 1 22 30 4 23* 17 19 Y 36 35 28 29 n 27 NOTE:Seal lips face upward 26 10 307043 Parts HINGED CLAMP MOUNTING: SANITARYModel 207546, Series H, Air Motor AssemblyIncludes items 1–36
Page 16 - Accessories
16 307043 Accessories BLEED-TYPE MASTER AIR VALVE (REQUIRED)300 psi (21 bar, 2.1 MPa) Maximum Working PressureRelieves air trapped in the air line between the pumpair inlet and this valve when closed. 107141 3/4 npt (m x f) inlet and outlet107142 1/2 npt (m x f) inlet and outlet SILENCER KIT 215354F...
Page 17 - Technical Data
17 307043 Dimensional Drawings 05709 11.75 in.(298.4 mm) 13.25 in.(336.6 mm) 15.75 in.(400.1 mm)for 206955 5.75 in.(146.1 mm) Mounting Hole Layouts Three 0.34 in. (8.6 mm)diameter holeson 6.38 in. (162.1 mm) boltcircle 3 Tie Rod Pumps 05707 05708 45_ 45_ 2.5 in. (64 mm) 2.5 in.(64 mm) 4 in. (102 mm)...