Page 2 - Assembly Drawing, SaniSpray HP 20 Corded
2 3A7932C Assembly Drawing, SaniSpray HP 20 Corded Torque to 55-65 in-lb (6.2-7.3 N•m) Torque to 23-25 in-lb (2.6-2.8 N•m) Torque to 10-15 in-lb (1.1-1.7 N•m) Torque to 10 in-lb (1.1 N•m) 1 2 3 4 4 4
Page 3 - Parts List - HP 20 Corded
3A7932C 3 Parts List - HP 20 Corded Ref. Sprayer Model Part Description Qty. 1 All 19Y962 KIT, pump, assembly 1 2 25R790, 25R960 19Y963 KIT, motor, AC, 120V 1 25R943, 25R952 25T400 KIT, motor, AC, 230V 1 3 25R790, 25R960 19Y964 KIT, SmartControl with enclosure, 120V 1 25R943, 25R952 25T401 KIT, Smar...
Page 4 - Assembly Drawing, SaniSpray HP 20 Cordless
4 3A7932C Assembly Drawing, SaniSpray HP 20 Cordless Torque to 55-65 in-lb (6.2-7.3 N•m) Torque to 23-25 in-lb (2.6-2.8 N•m) Torque to 10-15 in-lb (1.1-1.7 N•m) Torque to 10 in-lb (1.1 N•m) 1 2 3 4 4 4
Page 5 - Parts List - HP 20 Cordless
3A7932C 5 Parts List - HP 20 Cordless Ref. Sprayer Model Part Description Qty. 1 All 19Y967 KIT, pump, assembly 1 4 All 19Y968 KIT, SmartControl with enclosure, 120V 1 5 All 17P552 KIT, cup assembly, 42 oz. 1 6 All 17P712 CAP (3-pack) 1 7 All 17P549 FLEXLINER, 42 oz. (25-pack) 1 8 All LP313 TIP, LP3...
Page 6 - Assembly Drawing, SaniSpray HP 20 Electrostatic
6 3A7932C Assembly Drawing, SaniSpray HP 20 Electrostatic Torque to 55-65 in-lb (6.2-7.3 N•m) Torque to 23-25 in-lb (2.6-2.8 N•m) Torque to 10-15 in-lb (1.1-1.7 N•m) Torque to 10 in-lb (1.1 N•m) 1 2 3 4 4 4
Page 7 - Parts List - HP 20 Electrostatic
3A7932C 7 Parts List - HP 20 Electrostatic Ref. Sprayer Model Part Description Qty. 1 All 25T784 KIT, pump, assembly 1 4 All 25T785 KIT, SmartControl with enclosure 1 5 All 17P552 KIT, cup assembly, 42 oz. 1 6 All 17P712 CAP (3-pack) 1 7 All 17P549 FLEXLINER, 42 oz. (25-pack) 1 8 All LP313 TIP, LP31...
Page 8 - Removal; Installation
8 3A7932C Enclosure Cover Removal/Installation Removal Before servicing the sprayer, the enclosure cover must be removed by following these steps:1. Perform Pressure Relief Procedure , page 1. 2. Verify the power has been disconnected before proceeding. 3. Remove cup assembly. 4. Turn Prime Knob for...
Page 9 - Outlet Valve Replacement
3A7932C 9 Outlet Valve Replacement Worn outlet valves are easily replaced without removing the enclosure cover.1. Perform Pressure Relief Procedure , page 1. 2. Verify the power has been disconnected before proceeding. 3. To remove the three outlet valves (c), remove two pump plugs (b) and front val...
Page 12 - Motor Replacement; HP 20 Cordless
12 3A7932C Motor Replacement To replace the motor you must first remove the enclosure cover. 1. Perform Pressure Relief Procedure , page 1. 2. Verify the power has been disconnected before proceeding. 3. Remove the enclosure cover. See Enclosure Cover Removal/Installation , page 8. HP 20 Cordless Fo...
Page 14 - Notes
Page 15 - Graco Information
Graco Information 3A7932C 15 Graco Information For the latest information about Graco products, visit www.graco.com . For patent information, see www.graco.com/patents . TO PLACE AN ORDER, contact your Graco distributor or call 1-800-690-2894 to identify the nearest distributor.