Page 2 - INDEX; THE
2 M0302 EN INDEX A GENERAL WARNINGS 3 B FIRST AID RULES 3 B.1 WARNINGS 4 C THE DISPENSING NOZZLE 6 C.1 INTENDED USE 6 D TECHNICAL DATA 6 E INSTALLATION 6 F MODES OF OPERATION 7 G PREVENTION MISFILLING (optional) 7 H PRELIMINARY CHECK 8 I INITIAL START UP 9 J MAINTENANCE 9 K MALFUNCTIONS 9 L DEMOLITI...
Page 3 - GENERAL WARNINGS; Symbols used; This symbol indicates that there is risk of damage to; FIRST AID RULES; Contact with; WARNING
M0302 3 EN A GENERAL WARNINGS Important precautions To ensure operator safety and to protect the pump from potential damage, workers must be fully acquainted with this instruction manual before performing any operation. Symbols used in the manual The following symbols will be used throughout the man...
Page 4 - EQUIPMENT
4 M0302 EN B.1 WARNINGS The following warnings are for the setup, use, grounding, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warn- ing ...
Page 6 - THE DISPENSING NOZZLE; data; TECHNICAL; NOTE; The wetted materials used in this device are :; INSTALLATION; NO PTFE TAPE
6 M0302 EN C THE DISPENSING NOZZLE FOREWORD DISPENSER NOZZLE FEATURING AUTOMATIC STOP DE- VICE, MADE OF NON-CONDUCTIVE PLASTIC AND DE- SIGNED TO BE USED WITH WATER/UREA SOLUTION (DEF, AUS32). ALSO COMPATIBLE WITH WATER C.1 INTENDED USE P.N. 127649 WATER/UREA SOLUTION - D.E.F. - AUS 32, ACCORDING TO ...
Page 7 - MODES OF OPERATION
M0302 7 EN F MODES OF OPERATION FOREWORD The main feature of these nozzles is that they are easy to use. Two operating modes are available: 1 ASSISTED MODE Dispense by operating the nozzle lever. To interrupt dis- pensing manually, release the lever. 2 AUTOMATIC MODE Use the opening lever lock devic...
Page 8 - PRELIMINARY CHECK; NOTICE
8 M0302 EN H PRELIMINARY CHECK NOTICE Check the correct operation of the lock device, ac- cording to the following procedure: 1 Take a graduated receptacle with a capacity of 20 litres (5 gal) LOW CLIP 2 Begin dispensing into the receptacle, setting the lever in the minimum flow position, until the ...
Page 9 - INITIAL START UP; MAINTENANCE; PERIODICALLY CHECK THE CORRECT OPERATION OF THE AUTOMATIC; MALFUNCTIONS
M0302 9 EN I INITIAL START UP FOREWORD Only start dispensing after making sure that assembly and installation have been correctly performed. WARNING TOXIC FLUID OR FUMES HAZARD The faulty operation of this device could cause the spill of liquids that are hazardous for people and the envi- ronment. N...
Page 11 - This page left intentionally blank
Page 12 - Graco Extended Warranty; MANUFACTURED BY GRACO.; Graco Information; TO PLACE AN ORDER; Minneapolis; International Offices:
Graco Extended Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, ex- tended, or limited wa...