Page 2 - Warning Symbol; Caution Symbol; CAUTION; WARNING; INJECTION HAZARD
308–367 Table of Contents Warnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Assembling the Sprayer 4 . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 7 . . . . . . ....
Page 3 - EQUIPMENT MISUSE HAZARD; FIRE AND EXPLOSION HAZARD
3 308–367 WARNING INSTRUCTIONS EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture, malfunction, or start unexpectedly and resultin a serious injury. This equipment is for professional use only. Read all the instruction manuals, tags, and labels before operating the equipment...
Page 4 - Assembling the Sprayer; Cart Mounted Pump; Pail Mounted Pump
4 308–367 Assembling the Sprayer Cart Mounted Pump Assemble the suction hose (6) to the elbow (5) at thepump intake. Screw the suction tube (7) onto the otherend of the hose. See Fig. 1. Fig. 1 03356 7 6 5 Wall Mount Pump 1. Screw the gauges (25) into the air regulators (F,G). See Fig. 2. 2. Connect...
Page 5 - Installation; System Accessories; Grounding
5 308–367 Installation Be sure that all operators read and understand thisentire manual and the separate manuals supplied withcomponents and accessories before using this equip-ment. Reference numbers and letters in parentheses refer tothe figures and parts drawings. Accessories mentioned are availa...
Page 6 - Hose and Gun Connections
6 308–367 Installation Fig. 4 KEY A Pump B Bleed-Type Master Air Valve(required for pump) C Air Supply Line D Master Air Valve (for accessories) E Air Line Filter F Pump Air Regulator G Gun Air Regulator H Fluid Drain Valve (required) J Fluid Suction Line K Fluid Filter L Gun Fluid Supply Hose M Gun...
Page 7 - Operation; Pressure Relief Procedure; Flush the Pump Before Using
7 308–367 Operation Pressure Relief Procedure WARNING INJECTION HAZARDFluid under high pressure can be in-jected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or movingparts, follow the Pressure Relief Procedurewhenever you: are instructe...
Page 8 - Starting and Adjusting the Pump; Shutdown and Care
8 308–367 Operation Starting and Adjusting the Pump WARNING To reduce the risk of serious injury whenever youare instructed to relieve pressure, always follow thePressure Relief Procedure on page 7. See Fig. 5. Be sure the air regulators (F, G) and bleed-type master air valve (B) are closed. Do not ...
Page 10 - Parts
10 308–367 Parts See Detail. NOTE: Apply thread sealant to all male threads, except at swivel connections. 1 2 3 4 5 6 7 8 9 10 10 11 12 13 14 15 15 (Ref) 16 17 18 19 19 23 24 25 26 28 29 30 31 32 37 47 A A 37 (Ref) 10 Part No. 236–721Cart Mounted Pump
Page 15 - Technical Data; Manual Change Summary
15 308–367 Parts Part No. 236–723 Wall Mounted Pump RefNo. Part No. Description Qty. 1 159–101 HOUSING, suction tube intake 1 3 214–961 HOSE, suction, fluid; nylon3/4 npt(mbe); 3/4” (19 mm) ID;6 ft (1.83 m) long 1 4 161–377 SCREEN, suction tube intake 1 5 223–596 MONARK PUMPSee manual 307–619 for pa...
Page 16 - The Graco Warranty; Graco Phone Number
16 308–367 The Graco Warranty Graco warrants all equipment listed in this manual which is manufactured by Graco and bearing its name to be free from defects inmaterial and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception ofany s...