Page 2 - PRODUCT IDENTIFICATION; SUPPLY; Brand; AIRFLO W
PRODUCT IDENTIFICATION 2 The model and manufacturing number are used for positive identification of component parts used in manufacturing.Please use these numbers when requesting service or parts information. Installation and repair of this unitshould be performed ONLY by in-dividuals meeting the re...
Page 3 - All models are low NOx models.
PRODUCT IDENTIFICATION 3 The model and manufacturing number are used for positive identification of component parts used in manufacturing.Please use these numbers when requesting service or parts information. GME80703BXC* GME80905CXC* GME81155CXC* All models are low NOx models. The United States Env...
Page 4 - PRODUCT DESIGN; Left; General Operation; WARNING; III
4 PRODUCT DESIGN NOTE: Gas furnaces with induced draft blowers draw products of combustion through a heat exchanger allowing,in some instances, common venting with natural draftappliances (i.e. water heaters). All installations must bevented in accordance with National Fuel Gas Code NFPA54/ANSI Z223...
Page 5 - for servicing; High Altitude Derate; Pressure
5 PRODUCT DESIGN Accessibility Clearances (Minimum) Unobstructed front clearanace of 24" for servicing is rec- ommended. Top clearance for horizontal confirguration - 1" MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS - INCHE S SW B 1 0 3 C 6 1 1 ** Si ngle Wal l Vent (SW) to be used only as a co...
Page 6 - PRODUCT DIMENSIONS; UNI TS; All dimensions are in inches .
PRODUCT DIMENSIONS 6 GME8*****XA UNI TS A B C D GME80703BX C* 17.5 16 33-3/8 28 GME80905CXC*GME81155CXC* 21 19.5 33-3/8 28 All dimensions are in inches .
Page 7 - All installas above 7,000 ft. require a pressure switch change.; Part Nu mb er
7 PRODUCT DESIGN * All installas above 7,000 ft. require a pressure switch change. For installations in Canada, the GME8 furnace is certified only to 4,500 ft. * Negative pressure readings are in inches of water column (*w.c.) Part Nu mb er 20162903 Op en Set ting (°F) 160 G ME80703BXC* 1 G ME80905C...
Page 8 - A large array of Amana; • All CAPF coils have a CAUF equivalent.; PRO DUCT
8 PRODUCT DESIGN Coil Matches: A large array of Amana ® brand coils are available for use with the new GME8 furnaces, in either upflow or horizontal applications. These coils are available in both cased and uncased models (with the option of a field installed TXV expansiondevice). These 80% furnaces...
Page 9 - Filters can also be installed elsewhere in; Upflow Filters; Bottom Return; FURNACE INPUT
9 PRODUCT DESIGN Thermostats: NOTE: Complete lineup of thermostats can be found in the Thermostat Specification Sheets. Filters: Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 orCAN/ULCS111 standards. Installing this furnace with...
Page 11 - FURNACE SPECIFICATIONS; MO DEL
FURNACE SPECIFICATIONS 11 Unit specifications are subject to change without notice. ALWAYS refer to the unit's serial plate for the most up-to-date general and electrical information. NOTES: * These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to pr...
Page 12 - BLOWER PERFORMANCE SPECIFICATIONS; For most jobs, about 400 CFM per ton when cooling is desirable.; BL OW ER PERFORMANCE; Model
BLOWER PERFORMANCE SPECIFICATIONS 12 1. CFM in chart is without filters(s). Filters do not ship with this furnace, but must be provided by the installer. 2. All furnaces ship as high speed cooling. Installer must adjust blower cooling speed as needed. 3. For most jobs, about 400 CFM per ton when coo...
Page 13 - TEM
BLOWER PERFORMANCE SPECIFICATIONS 13 30 4 0 5 0 60 70 8 0 90 1 1 0 1 2 0 10 0 13 0 1 4 0 1 5 0 10 0 90 80 70 60 50 40 30 20 10 O U T P UT B T U/ HR x 1 0 00 B T U O U TPUT v s T E M P E R A T URE RI SE CHA RT TEM PE RA TURE RI SE 6 00 CF M 70 0 90 0 1 000 11 00 1 200 14 00 16 00 180 0 200 0 2 200 24...
Page 14 - WIRING DIAGRAMS
14 WIRING DIAGRAMS HIGH VOLTAGE!DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THISUNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TODO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-dat...
Page 16 - SCHEMATICS; TYPICAL SCHEMATIC
16 SCHEMATICS HIGH VOLTAGE!DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THISUNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TODO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. .0005 3M K4 K2 HI HEAT COOL PARK CIR NEU K5 GAS VALVE HIGH LIMIT AUX LIMIT PRESSURE SWITCH FLAME SENSOR...