Page 2 - Contents; Operator Menu
Contents Default Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . …………… 1 Menu Navigation Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . …………… 1 Text Entry Keys . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 3 - Diagrams
Contents Door Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. ..16 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 16 Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 4 - ACT1000/2000 Operating Instructions Software Version 3.23-00; Operating Instructions for; Operator; Default Codes; Menu System; Menu Navigation Keys; Text Entry; Text Entry Keys
ACT1000/2000 Operating Instructions Software Version 3.23-00 Page 1 of 32 Operating Instructions for ACT1000/2000 Access Control Units Software Version: 3.23-00 All user functions are accessed via two six-digit codes. The first code is for the Operator who is responsible for the day-to-day administr...
Page 5 - On the ACT2000, you will first be prompted for a door.
ACT1000/2000 Operating Instructions Software Version 3.23-00 Page 2 of 32 Operator Menu User Setup Enable Allow a user or range of users to open the door Disable Prevent a user or range of users from opening the door Assign Names Enter a name for each user Assign Groups Assign users to groups Assign...
Page 6 - User Setup; T Toggle
ACT1000/2000 Operating Instructions Software Version 3.23-00 Page 3 of 32 User Setup The User Setup menu allows the operator to enable and disable individual users, and to change the configuration information for each user. In each of the user setup functions, the user is selected by either using th...
Page 7 - Assign PINs; unset; PIN Only; Batch Cards; Not Assigned
ACT1000/2000 Operating Instructions Software Version 3.23-00 Page 4 of 32 Assign PINs The Assign PINs function allows a different PIN to be assigned to each of the first 1000/2000 users. Initially, the PIN will be unset . Pressing the ✔ ✔ ✔ ✔ key will prompt for the PIN for the displayed user to be ...
Page 8 - Group Setup; Group 3
ACT1000/2000 Operating Instructions Software Version 3.23-00 Page 5 of 32 One-To-One In One-To-One Mode , any known card may be assigned to any of the first 1000/2000 users. If the site code and card number are known then they may be entered in from the keypad or the card may also be presented to a ...
Page 9 - Full Access; or; No Access; may quickly be set for the group by; Assign Options; Option; System Log
ACT1000/2000 Operating Instructions Software Version 3.23-00 Page 6 of 32 3) Changing timezone Timezone 0 for next timezone At all times ✔ ✔ ✔ ✔ to select 4) Changing door combination Door 7 0 for next door [23---7—AB] ✔ ✔ ✔ ✔ to select/deselect ✘ ✘ ✘ ✘ when done In addition, Full Access or No Acces...
Page 10 - Wiring between Printer & Controller: Controller; Filter Log
ACT1000/2000 Operating Instructions Software Version 3.23-00 Page 7 of 32 Display Log The Display Log function allows the operator to view events in the historical log directly on the LCD display. When this option is selected, the latest event in the log is displayed with the time and date on the to...
Page 11 - Control Door; Lock Door; Users
ACT1000/2000 Operating Instructions Software Version 3.23-00 Page 8 of 32 Control Door The Control Door menu allows the operator to control the door or externally connected equipment such as lighting or heating. Lock Door The Lock Door function causes the door relay to be de-energized. The bottom li...
Page 12 - even if power is not present.; Time Zones
ACT1000/2000 Operating Instructions Software Version 3.23-00 Page 9 of 32 Clear All (ACT2000 Only) This function manually removes all users from the area. An event is logged for tracking. This is typically used at the end of a day or week to remove any users from the system who have neglected to use...
Page 13 - symbols respectively:; Timezone N; whenever the timezone; Hours
ACT1000/2000 Operating Instructions Software Version 3.23-00 Page 10 of 32 1) Select Timezone Timezone 3 0 for next timezone Inactive ✔ ✔ ✔ ✔ to edit timezone 2) Select period A B C D E + - 0 for next period Week Days ✔ ✔ ✔ ✔ to edit period 08:30 -> 17:00 3) Changing days/holidays Wednesday 0 for...
Page 14 - Issue Number
ACT1000/2000 Operating Instructions Software Version 3.23-00 Page 11 of 32 Issue Number This option allows the user to set the current system issue level to a number between zero (default) and 255. Only cards that have an issue number greater than or equal to the system issue level will be granted a...
Page 15 - Installer Menu; System Settings; Feature present on ACT1000 only
ACT1000/2000 Operating Instructions Software Version 3.23-00 Page 12 of 32 Installer Menu System Settings Operation PIN Only PIN’s alone are used to gain access Learn Users 1-1/2000 may use random coded cards Ext. Keypad 1 Use external ACT20 keypad KPD Release 1 ✔ ✔ ✔ ✔ Key is exit button. Exit PIN’...
Page 16 - Timed Actions; any; Communications
ACT1000/2000 Operating Instructions Software Version 3.23-00 Page 13 of 32 Door Settings* Timers Relay Time Time for which relay is active (contd.) OP2 Time Time for which OP2 is active OP3 Time Time for which OP3 is active Ajar Time Max time which door can be open AUX Time Time for which AUX output...
Page 17 - Operation
ACT1000/2000 Operating Instructions Software Version 3.23-00 Page 14 of 32 System Settings The System Settings menu allows the installer to access a number of different configuration menus controlling different aspects of the setup of the controller. Pressing the ✔ ✔ ✔ ✔ key toggles the setting of a...
Page 18 - Fire Doors; AUX input on door 1
ACT1000/2000 Operating Instructions Software Version 3.23-00 Page 15 of 32 Fire Doors This function allows a group of doors (or all doors) to be configured for fire override. A 0Volt signal from a fire alarm (or other) system is applied to the AUX input on door 1 . This maintains normal operation. W...
Page 19 - Door Settings
ACT1000/2000 Operating Instructions Software Version 3.23-00 Page 16 of 32 Door Settings The Door Settings menu allows the installer to access a number of different configuration menus controlling different aspects of the selected door. The door for which the settings are to be changed is first sele...
Page 20 - Timers; unlocked
ACT1000/2000 Operating Instructions Software Version 3.23-00 Page 17 of 32 Timers The door timers menu allows the installer to program the time delays for the relay, AUX output, open collector outputs OP2 and OP3 and the door ajar alarm time. Each timer may be programmed with a duration from 1 to 99...
Page 21 - High Speed; in slave mode only; Print All; Door 3; Set Password; Card Setup
ACT1000/2000 Operating Instructions Software Version 3.23-00 Page 18 of 32 High Speed Communications on the controller defaults to 9600 baud. The high speed option sets the controller to operate at 19200 baud. This option applies to direct connect to a PC, networked interface and printer modes of op...
Page 22 - Site Code 1; also; Change PIN; Factory Default
ACT1000/2000 Operating Instructions Software Version 3.23-00 Page 19 of 32 Site Code 1 This function allows the 8-digit site primary code for the system to be entered. The controller will recognize only cards with a matching site code. This code should also be quoted whenever additional cards or tag...
Page 23 - IN; Always Place Varistor
Card or Proximity Reader SENSECLOCKDATA+5V0VRED GREEN Volt Free Tamper Contacts +12V 0V PUSH BUTTON DOOR CONTACT INTER LOCK 0V OP2OP3 BUZZER 12V+ DC- R E L A Y N/C C N/O N E T WO R K P R IN T E R T A M P E R T im e k e e p e r L it h iu m B a tt e ry AB 0V TX RX OMRON 5A 250VAC5A 30VDC BATCH: 96XX-1...
Page 24 - Door 2 Contact
1A 25 0V AC 1A 30 VD C 0 1 2 3 4 5 6 7 8 9 BATCH: PRODUCT: SERIAL NUMBER: 98XX-1 ACT2000 REV2.1 00XXXX 0V DOOR CONTACT PUSH BUTTON AUX INPUT RELAY 1 N/C N/O C OP2 OP3 SENSE CLOCK DATA RED GREEN EN TR Y /E X IT R EA D ER 1 A B 0V TX RX NETWORK 5A 250VAC5A 30VDC 1A 25 0V AC 1A 30 VD C 5A 250VAC 5A 30V...
Page 25 - Door Release Button; Power; Wiring for Clock and Data / Wiegand Reader; DS100 Door Station Installation
To set the door number,set address switches4-8 as shown NETWORK Important !Always Place VaristorAcross Lock Terminals Door Release Button A B A Shield FACTORY DEFAULTThis unit should be reset to itsfactory default condition beforeinstallation. To do this, powerthe unit up with ALL switches in the OF...
Page 26 - Controller; rd; For Wiegand Exit readers; readers; Wiring for Entry/Exit Readers
Card / Proximity or Pin Reader (Entry) Card or Proximity Reader (Exit) Controller SENSECLOCKDATA+5V0VREDGREEN C a rd /P ro x R e a d e r 2 3 1 5 6 4 8 9 7 0 For Wiegand Exit readers Connect DATA 0 of the exit readerto SENSE on the controller. LeaveSENSE on the readers unconnected. Wire both readers ...
Page 27 - Controller Cable ACT20; ACT20 PIN Pad Installation Diagram
Cable: 8 Core Screened, Max 30m Controller EN TR Y/E XIT R EA DE R 0 1 2 3 4 5 6 7 8 9 BATCH: PRODUCT: SERIAL NUMBER: 98XX-1 ACT20 REV2.1 012345 OP2 OP3 BUZZER 0V 0V DOOR CONTACT PUSH BUTTON INTERLOCK (PB2) T A M P E R 12 -2 4V A C /D C + - WHI TE GRE EN BLU E BROW N YELLO W BLA CK RED O RA N G E SE...
Page 29 - Interlock Configuration; Fire Override Configuration
LED2 LED1 DOOR I/O SERIAL NETWORK ENTRY/EXIT READER G E N E R A L I /O R E LA Y TAMPER MAINS +12V 0V N /CC A U X R LY N /O N /CCN /O S E N S E C L O C K D A T A + 5 V 0 V R E D G R E E N 5 A 2 5 0 V A C 5 A 3 0 V D C 5A 250VAC5A 30VDC P U S H B U T T O N D O O R C O N T A C T A U X 0 V O P 2 O P 3 1...
Page 30 - ACTWinPro Configuration; ACTWinPro; From the Installer Menu, do the following:; Click here to configure Comms; Direct Connect Cable
ACTWinPro Configuration A B 0V TX RX NETWORK D O O R S A B0V SE RIA L/P RIN TE R 0V DTR RED GREEN ACTWinPro From the Installer Menu, do the following: 1. Factory Default the controller. 2. Go to the Communications menu and Set Address. If there is only 1 controller, set the address to 1. For more th...
Page 31 - ACT 4-Line Network Wiring
To PC To Mains Supply ACT 4-Line Nework Interface Card All lines are equivalent and operate in parallel Any controller may be connected to any line. Network cable is single shielded twisted pair: Belden 9501 or similar ACT 2000 ACT 1000 ACT 1000 Line 1 Line 2 Line 3 Line 4 S C N C D I D O +BAT- N E ...
Page 32 - Setup for Network Operation; ACTWin Software; Pin; ACT Single Line RS-485 Converter
Setup for Network Operation 4 3 2 1 B A U D R A T E S E L E C T 9 6 0 0 1 9 2 0 0 Network cable is single shielded twisted pair: Belden 9501 or similar ACT 2000 ACT 1000 ACT 1000 N E T WO R K P R IN T E R T im e k e e p e r L it h iu m B a tt e ry AB 0V TX RX T im e k e e p e r L it h iu m B a tt e ...
Page 33 - Direct Connection from Modem to Controller; Locations and Connections; ACTWinPro Setup for Modem Operation; Modem Connection for ACT Network; ACT Modem Configuration
DB25 Male(Rear View) 7 3 2 Max cable length is 5m using standard alarm cableor 30m using twin twisted-pair (use 0V in each pair) Direct Connection from Modem to Controller Connections for 25 Way male Connector RX = Pin 3 TX = Pin 2 0V = Pin 7 1. Connect Modem Cable directly to ACT1000/2000 and Modem...
Page 34 - TCP/IP Configuration; ACT Network Interface Card; ACTLAN Configuration Diagram
ACTWinPro Software 1. Ask the network administrator to supply you with a permanent IP network address. 2. Connect a PC directly to the ACTLAN and run HyperTerminal at 9600 baud, no parity, 1 stop. 3. Power up the ACTLAN and immediately hit 3 lowercase "x" (xxx). 4. Hit the Enter key to go in...
Page 35 - ACT System Diagram
PSTN RS232 ACTWinPro Door 16 ACT2000 DS100 DS100 DS100 Door 3 Door 4 Door 2 Door 1 485Converter System Diagram: Illustrating some of the ways to connect ACT Controllers to a computer. Modem RS232 RS485 Line 4 RS485 Line 2 RS485 Line 3 ACT2000 DS100 DS100 DS100 Door 3 Door 4 Door 2 Door 1 Door 16 ACT...