Page 2 - Make sure the voltage specified as correct for the device.; Security Statement; the machinery have the same obligations:; Manufacturer's Declaration; Product life: 5 years; Figure 1
Copyright All Rights Reserved. P-MU-AD425S Ver. A Publish:2008.07.11 Page: 2/ 20 z Make sure the voltage specified as correct for the device. z Must provide at least 10 seconds rest time between every restarting cycle to ensure adequate residual current can be returned to power system. z Make sure t...
Page 3 - All Packing materials; Name
Copyright All Rights Reserved. P-MU-AD425S Ver. A Publish:2008.07.11 Page: 3/ 20 All Packing materials 1. Construction Name ○ 1 Cover ○ 2 Motor ○ 3 Reducer ○ 4 Square Couplings ○ 5 Control Board ○ 6 Battery ○ 7 Power Switch ○ 8 Operating Arm ○ 9 Sliding Rail ○ 10 Stopper Ball ○ 11 Baseplate ○ 12 Tra...
Page 4 - See; Motor
Copyright All Rights Reserved. P-MU-AD425S Ver. A Publish:2008.07.11 Page: 4/ 20 3. Control Board Guide Input/Output Contact Explanation Remark Make sure the input is used correctly (AC110 or 220V). When turn on the power switch, it enters a learning mode. Power Switch AD-425S Operating Arm turns cl...
Page 6 - The opening, closing and maintain -open time illustration table.
Copyright All Rights Reserved. P-MU-AD425S Ver. A Publish:2008.07.11 Page: 6/ 20 The opening, closing and maintain -open time illustration table. VM (Opening and Closing Time Adjustment ) Opening and Closing Operating Time Total Opening and Closing Time (VM+ Brake Time) TC Time (Maintain -open time ...
Page 7 - Figure 2
Copyright All Rights Reserved. P-MU-AD425S Ver. A Publish:2008.07.11 Page: 7/ 20 5. Specification Power Input 110V (or 220V) AC , 50-60Hz Current (See Figure 2 ) 3.5A max., 0.6A average Torque 30Nm Opening/Closing time (VM) 4.5~9.5 s ( 90° ) Maintain - Open time (TC) 1~35 seconds Battery Specificati...
Page 8 - Installation instructions; Figure 3; Beginning; Prepare the installation
Copyright All Rights Reserved. P-MU-AD425S Ver. A Publish:2008.07.11 Page: 8/ 20 Installation instructions z Refer to figure 3 for in-swing door (right-hand). Figure 3 z Opening, Closing action time and Maintain time illustration. AD-425S will be automatically counted the round trip distance and can...
Page 9 - Figure 5 Figure 6 Figure 7 Figure 8; Figure 9; Figure 9 Figure 10
Copyright All Rights Reserved. P-MU-AD425S Ver. A Publish:2008.07.11 Page: 9/ 20 Figure 5 : For right-hand and out-swing door. F/R switch set 「 ON 」 . Operating Arm mounts to left-side. Figure 6 : For left-hand and out-swing door. F/R switch set 「 1 」 . Operating Arm mounts to right-side. Figure 7 :...
Page 10 - Figure; : Automatic door operator dimension; Figure 15 Figure 16; Warning
Copyright All Rights Reserved. P-MU-AD425S Ver. A Publish:2008.07.11 Page: 10/ 20 z Figure 11~13 showing an operator installation of a minimum door leaf width and a maximum opening angle. The opening angle is recommended not excess to 120 ∘ . Figure 11 Figure 12 Figure 13 z Figure 14 : Automatic doo...
Page 11 - AD-425S Template Installation Instruction
Copyright All Rights Reserved. P-MU-AD425S Ver. A Publish:2008.07.11 Page: 11/ 20 AD-425S Template Installation Instruction Figure 17 Out-swing door (Right-Hand Open) Figure 18 Out-swing door (Left-Hand Open) Figure 19 In-swing door (Right-Hand Open) Figure 20 In-swing door (Left-Hand Open)
Page 12 - Installation Steps
Copyright All Rights Reserved. P-MU-AD425S Ver. A Publish:2008.07.11 Page: 12/ 20 Installation Steps Out-swing door ( Right-Hand Open ) Step Figures Explanation Step 1. Place the AD-425S template to the right position on the door header. See the figure presented for an out-swing door (Right-Hand Ope...
Page 16 - Control Board
Copyright All Rights Reserved. P-MU-AD425S Ver. A Publish:2008.07.11 Page: 16/ 20 Steps Figures Explanation Step 24. Fix the Sliding Rail on the door leaf. (Screw specification: 6 X 20 mm) Step 25. Slide in the Sliding Rail Cover. Step 26. Attach two Side Ends. Step 27. Depending on the door leaf op...
Page 17 - Battery
Copyright All Rights Reserved. P-MU-AD425S Ver. A Publish:2008.07.11 Page: 17/ 20 Steps Figures Explanation Step 30. First opening movement, the AD-425S will be automatically set the opening angle and distance. Step 31. Attach the cover. Step 32. Attach the Operating Arm cap. Make final settings and...
Page 18 - Trouble shooting; electromagnetic
Copyright All Rights Reserved. P-MU-AD425S Ver. A Publish:2008.07.11 Page: 18/ 20 Trouble shooting Problem Possible Cause Solution No AC power Make sure the Control Board and fuse are working properly and connected properly. Motor have no power (LED motor light not on.) Make sure all motor terminals...
Page 20 - General Safety Precautions
Copyright All Rights Reserved. P-MU-AD425S Ver. A Publish:2008.07.11 Page: 20/ 20 General Safety Precautions The following precautions are essential for the user. z Read the precaution below carefully as it contains important information about safe installation and maintenance. z This instruction mu...