Page 2 - Special Purpose Circuit Breakers; & Combination Arc Fault Circuit Breaker; S e c t i o n 1; Q-Line Circuit Breaker s; Reliability and Economy; BuyLog
Special Purpose Circuit Breakers —PowerMark Gold Main Circuit Breakers—Arc Fault Circuit Interrupter—Dual Function GFCI/AFCI Ground Fault & Combination Arc Fault Circuit Breaker —Ground Fault with Self-Test Feature—Ground Fault with Equipment Protection—Switching Neutral—HID Lighting Breaker—Hig...
Page 3 - Safety accessories – convenient and easy to install; PowerMark Gold Load Cent er s; Highest Quality and Convenience; Accessories and Options
PowerMark Gold load centers lower your costs by making installa-tion faster and easier, increasing application flexibility and reduc-ing inventory requirements. At the same time, they deliver obviousand significant advances in design, function and quality.—UL Listed (Panelboards No. 67)—Suitable for...
Page 4 - Product Number Guide for Load Centers; CU; GE Identification; Product Number Guide for Q-Line Plug-in Circuit Breakers; (Product number for illustrative purposes only); QL; GE Identification; Ampere Rating; GFT; PowerMark Gold and Plus Load Cent er s; Product Number Guides
Product Number Guide for Load Centers (Product number for illustrative purposes only) 20 4 C B CU 42 M T GE Identification Type M = Main breaker L = Main lug LM = Convertible PL = Main lug (Thermoplastic) Insert for PowerMark Gold CU = Copper Bus 42 = Copper Bus Full 42 circuit panel Maximum Number ...
Page 5 - L o a d C e n t e r s a n d C i rc u i t B re a k e r s; Q-Line Plug-in Circuit Breakers Specifications
L o a d C e n t e r s a n d C i rc u i t B re a k e r s Q-Line Plug-in Circuit Breaker s UL Listed (Molded Case Circuit Breakers No. 489)Federal Government Specification Qualified (WC-375B)60°C / 75°C Conductor RatingQuick Make, Quick BreakBox Type Terminals Q-Line Plug-in Circuit Breakers 10,000AIC...
Page 6 - Special Purpose Circuit Breaker s; Arc Fault; UL Listed; Ground Fault with Self-Test Feature; cULus; T H Q M V 1 0 0 D w i t h f i l l e r p l a t e s
www.geindustrial.com Rev. 11/13 Data subject to change without notice BuyLog ™ Catalog 1-6 L o a d C e n t e r s a n d C i rc u i t B re a k e r s Special Purpose Circuit Breaker s 60°C / 75°F Conductor RatingBox Type TerminalsQuick-Make, Quick-BreakMulti-pole Breakers Incorporate Internal Common Tr...
Page 7 - PowerMark Gold Main Circuit Breaker Kit; Ground Fault with Equipment Protection; Switching Neutral
PowerMark Gold Main Circuit Breaker Kit For use with 125A PowerMark Gold load Centers; 22kAIC RMS symmetrical. Description Product Number Main Circuit Breaker Kit - Order appropriate THQL TQMH000 1 10kAIC or THHQL 22kAIC breakers separately 1 Please review the footnotes listed with the individual Lo...
Page 8 - Molded Case Switches; Two breakers required for interlocking.
TQ Circuit Breakers 3/4" UL Classified Circuit Breakers for use in *Square D **QO Load Centers.10 kAIC RMS symmetrical 1-Pole 2-Pole Ampere Rating Product Number Product Number 15 TQ1115 TQ2115 20 TQ1120 TQ2120 30 TQ1130 TQ2130 40 TQ1140 TQ2140 50 TQ1150 TQ2150 60 – TQ2160 Std. Pkg. 1 carton of ...
Page 9 - Product Features; in Accordance with the National Electrical Code; Load Center; Main Lugs Convertible to Main Breaker
Product Features —UL Listed (Panelboards No. 67)—60°/75°C Conductor Rating—Suitable for Use as Service Entrance Equipment when Installed in Accordance with the National Electrical Code —22kAIC RMS symmetrical, Except Where Noted—6-42 circuit devices UL Listed for bottom mounted lugs by installing co...
Page 10 - PowerMark Gold and Plus Load Centers
Main Lugs Factory Installed (TLM units convertible to main breaker), Indoor (NEMA 1) Enclosure Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size Ampere 1” 1” 1/2” 1/2” 1-pole Front Box (AWG/kcmil) Equipment Product Rating Spaces Spaces Spaces Spaces Spaces Type Feed Type Number Cu-Al Ground ...
Page 12 - PowerMark Gold and Plus Main Breaker Load Cent er s; Main Breaker Factory Installed
Product Features —UL Listed (Panelboards No. 67)—60°C/75°C Conductor Rating—Suitable for Use as Service Entrance Equipment when Installed in Accordance with the National Electrical Code —22kAIC RMS symmetrical, Except Where Noted—6-42 circuit devices UL Listed for bottom mounted lugs by installing c...
Page 14 - PowerMark Plus; Main Lugs Factory Installed
Product Features —UL Listed (Panelboards No. 67)—60°/75°C Conductor Rating—Suitable for Use as Service Entrance Equipment when Installed in Accordance with the National Electrical Code —22kAIC RMS symmetrical Short-circuit Rating Standard—Bottom feed models available where noted with a “B” suffix.—F...
Page 15 - This table continued on next page
Main Lugs Factory Installed 1 Outdoor (NEMA 3R) Enclosure Main 1 Pole, 2 Pole, 3 Pole, Total Main Wire Size Ampere 1” 1” 1” 1-pole Feed Box (AWG/kcmil) Equipment Product Rating Spaces Spaces Spaces Spaces Type Number Cu-Al Ground Kit Number 125 12 6 4 12 Top R3 6-2/0 TGK12 (order separately) TL12412...
Page 17 - T M 8 3 0 F C U G E N
Product Features - Generator Panels —Suitable for use in accordance with Article 702 of the National Electrical Code, ANSI/NFPA 70 —Single-phase, 2 interlock 60A or 30A main breakers, 8 circuits max. —Safety and convenience when using a generator - 14,000 peak wattage, 11,520 continuous load, 48 amp...
Page 18 - PowerMark Gold Met er Socket Load Cent er s
Single-Phase, Three-Wire, 120/240 Vac With Bonded Neutrals MainAmpere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Bypass UL Agency Product Rating 1” Spaces 1” Spaces 1/2” Spaces 1/2” Spaces Spaces Type Front Type Type Incoming Certification Number Meter Main - Ring Type, Field Installed M...
Page 23 - Application Data; Meter Socket LC; With Bonded Neutrals
Class 320 Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Ampere 1” 1” 1/2” 1/2” 1-pole Enclosure Bypass UL Agency Product Rating Spaces Spaces Spaces Spaces Spaces Type Front Type Type Incoming Certification Number 320 24 12 32 14 40 Outdoor Surf/Semi None UG UL TM2432RMS 1,2,3 (NEMA 3R) 400 0 0 0 0 0 O...
Page 24 - Circuit Breakers; Field Installed Accessories; PowerMark Plus; PowerMark Gold Equipment Ground and Isolated Ground Bar Kits; TG L 2
www.geindustrial.com Rev. 11/13 Data subject to change without notice BuyLog ™ Catalog 1-24 S e c t i o n 1 L o a d C e n t e r s a n d C i rc u i t B re a k e r s PowerMark Gold and Plus Load Cent er s Circuit Breakers Field Installed Accessories PowerMark Gold Main Circuit Breaker Kit For use with...
Page 25 - TG K 1 2 w i t h TG K I S
www.geindustrial.com BuyLog ™ Catalog 1-25 L o a d C e n t e r s a n d C i rc u i t B re a k e r s PowerMark Gold and Plus Load Cent er s Circuit Breakers Field Installed Accessories Rev. 11/13 Data subject to change without notice S e c t i o n 1 PowerMark Plus ™ Neutral Kits Wire Standard Product ...
Page 26 - P o w e r M a r k G o l d m a i n l u g k i t s - T M L K 2 0 0
www.geindustrial.com Rev. 11/13 Data subject to change without notice BuyLog ™ Catalog 1-26 L o a d C e n t e r s a n d C i rc u i t B re a k e r s PowerMark Gold and Plus Load Cent er s Circuit Breakers Field Installed Accessories S e c t i o n 1 PowerMark Plus ™ Main Lug Kits Product Description W...
Page 27 - Front Filler Plates; Door Handle; T F H
www.geindustrial.com BuyLog ™ Catalog 1-27 L o a d C e n t e r s a n d C i rc u i t B re a k e r s PowerMark Gold and Plus Load Cent er s Circuit Breakers Field Installed Accessories Rev. 11/13 Data subject to change without notice S e c t i o n 1 Front Filler Plates Standard Product Description Pac...
Page 28 - PowerMark Gold Main Breaker Retainers; Handle Ties; T H Q L R K
www.geindustrial.com Rev. 11/13 Data subject to change without notice BuyLog ™ Catalog 1-28 L o a d C e n t e r s a n d C i rc u i t B re a k e r s PowerMark Gold and Plus Load Cent er s Circuit Breakers Field Installed Accessories S e c t i o n 1 PowerMark Gold Main Breaker Retainers Product Descri...
Page 30 - Wiring Diagrams
www.geindustrial.com Rev. 11/13 Data subject to change without notice BuyLog ™ Catalog 1-30 L o a d C e n t e r s a n d C i rc u i t B re a k e r s PowerMark Gold and Plus Load Cent er s Circuit Breakers Wiring Diagrams S e c t i o n 1 Breaker Fill Breaker Symbol 1” THQL 1/2” THQP 1 — 1 2 Wire Range...
Page 37 - Indoor Enclosures; Knockouts; B ox 2
www.geindustrial.com BuyLog ™ Catalog 1-37 L o a d C e n t e r s a n d C i rc u i t B re a k e r s PowerMark Gold and Plus Load Cent er s Circuit Breakers Indoor Enclosures Rev. 11/13 Data subject to change without notice S e c t i o n 1 Symbol A • B C D E F G H J K L M N P Q R S T U V W X Y Z 5/16 ...
Page 38 - Outdoor Enclosures; A K D
www.geindustrial.com Rev. 11/13 Data subject to change without notice BuyLog ™ Catalog 1-38 L o a d C e n t e r s a n d C i rc u i t B re a k e r s PowerMark Gold and Plus Load Cent er s Circuit Breakers Outdoor Enclosures S e c t i o n 1 Symbol A • B C D E F G H J K L M N P Q R S T U V W X Y Z AA B...
Page 39 - Meter Socket Load Centers
www.geindustrial.com BuyLog ™ Catalog 1-39 L o a d C e n t e r s a n d C i rc u i t B re a k e r s PowerMark Gold and Plus Load Cent er s Circuit Breakers Meter Socket Load Centers Rev. 11/13 Data subject to change without notice S e c t i o n 1 Symbol A • B C D E F G H J K L M N P Q R S T U V W X Y...
Page 40 - B ox R 3 2 A
www.geindustrial.com Rev. 11/13 Data subject to change without notice BuyLog ™ Catalog 1-40 L o a d C e n t e r s a n d C i rc u i t B re a k e r s PowerMark Gold and Plus Load Cent er s Circuit Breakers Meter Socket Load Centers S e c t i o n 1 Symbol A • B C D E F G H J K L M N P Q R S T U V W X Y...