Furuno MFD8/12/BB - Manuals
Furuno MFD8/12/BB – Manual in PDF format online.
Manuals:
Manual Furuno MFD8/12/BB
Summary
2 Contents 1. Mounting ................................................................................................................ 11 1.1. MFD8/12 Mounting ........................................................................................... 11 1.1.1. MFD8/12 Flush Mounting .......
11 1. Mounting 1.1. MFD8/12 Mounting MFD8 MFD12 When selecting a mounting location for the NN3D MFD8/12, keep the following in mind: • The temperature and humidity of the mounting location should be moderate and stable. • Install the unit away from exhaust pipes and ventilators. • The mounting locat...
13 How to detach the front cover when flush mounted . To detach the front panel when the unit is flush mounted, use the special tool (supplied) as below. Note that the front cover may be damaged if this procedure is not followed! 1. Insert the tool in the notch on the lower side of the unit 2. Pull ...
15 1.2. MFDBB Processor Mounting The unit can be mounted on the deck, a desktop or on a bulkhead. Take special note that the MFDBB IS NOT WATERPROOF. Select a mounting location considering the points below: • Select a location where temperature and humidity are moderate and stable. • Consider the le...
17 How to detach the front panel when flush mounted To detach the front panel when the unit is flush mounted, use the tool (supplied) as below. Do not attempt to remove it by any other method, to prevent damage to the unit. 1. Insert the tool to the left-side notch at the bottom of the unit
20 2.1.2. MFDBB Overview 2.2. Power Connections 2.2.1. MFD8/12 The MFD8/12 can be powered directly using nominal 12V or 24V DC. Only use the power cable supplied with the unit and connect it to the Power Connector at the rear of the unit. 2.2.2. MFDBB The MCU001 - MFDBB processor unit can be powered...
23 Wiring Information Pin No. Color Function 7 Shield Shield 6 Black GND 5 Red 12V_OUT 4 Green RD1-C 3 Yellow RD1-H 2 Blue TD1-B 1 White TD1-A 2.3.3. DATA 2 Description DATA2 can be used to connect additional NMEA 0183 instruments. Use the included cable assembly FRUDD-18AFFM-L180 (FUSA P/N 000-164-...
24 Wiring Information Pin No. Color Function Remark (Port No.) 18 Light green NET-C IN (0V) NMEA 2000 Power IN. When 12V DC power is applied on these pins, the N2K port will be powered (up to 1 ampere) 17 Pink NET-S IN (+12V IN) 16 Purple Shield 15 White BUZZER or EVENT IN External Buzzer Output or ...
25 2.4. NMEA2000 Description and Information 2.4.1. MFD Every MFD has one NMEA2000 port (Standard “DeviceNet Micro” style connector). This port is not powered unless External Power is applied on Pin 18 and 17 of DATA2 and must be connected to a properly configured NMEA2000 network. IMPORTANT: Each M...
27 2.5. DRS (Radar) Connection Up to two DRS (Digital Radar Sensors) can be connected to a NavNet3D network. Every DRS comes with a supplied 15 Meter cable (FUSA P/N 000-167-636). Other cable lengths may be purchased if necessary (Note that the part numbers for the DRS25A are different): - 10 Meter ...
28 2.5.1. Connecting the DRS to MFD8/12 Standalone Installation: When the MFD8/12 and the Radar are the only Ethernet sensors, you can connect the Radar Ethernet connection directly to the back of the MFD8/12. Network Installation: As soon as multiple MFD8/12 or other Ethernet sensors (i.e. DFF1 Fis...
29 Example of straight Ethernet Coupler (FUSA P/N= RJ4-5CN-STR): Note: This Ethernet coupler is not waterproof. Ethernet Cables that can be used to extend the Ethernet Radar Connection: - 2 Meter RJ45 to RJ45 Ethernet Cable (P/N 000-167-175) - 5 Meter RJ45 to RJ45 Ethernet Cable (P/N 000-167-176) - ...
30 2.6. Network 2.6.1. Introduction NavNet3D (just like NavNet1 and VX2) uses standard TCP/IP Ethernet to share radar/sounder images and other navigation information from devices connected within a networked system. In any single NavNet 3D network, a combination of up to ten NavNet3D MFDs may be con...
31 two ports are NOT standard POE (Power over Ethernet) and POE devices cannot be connected to these two ports. 2.6.2. Power Synchronization A NN3D network is a system in which all components share information (navigation data, settings, points, routes, etc) with each other. Furuno developed special...
32 Why use the Furuno HUB (HUB101): The Furuno HUB101 allows the Power Synchronization signal to reach the MFDs and other Power Synchronization compatible devices. Here is a list of all devices that support Power Synchronization: - All NN3D Displays: MFD8, MFD12, MFDBB - All NN3D Radar Power Supplie...
33 The MFDBB processor unit has an Internal Hub that is compatible with Power Synchronization. DIP switches inside the processor unit can be turned ON or OFF to enable/disable the Power Synchronization feature. The number on each DIP switch corresponds to the port number. Additionally, to allow the ...
36 2.8. External Monitors 2.8.1. MFD8/12 A DVI monitor can be connected to the MFD8/12 to repeat the screen at a remote location. The plug is DVI-D format and only a DVI monitor can be connected. The MFD8 has a 640x480 (VGA) DVI-D output. The MFD12 has an 800x600 (SVGA) DVI-D output. Furuno offers t...
37 When Extended Mode is used the two screens need to be located in close proximity to each other. The two monitors show independent screen displays that can be configured independently. Only one Keyboard is used to control both monitors (the cursor will “jump” back and forth from monitor to monitor...
38 mouse software is permitted. However, the standard Mouse HID drivers will load automatically, allowing most mice and wireless mice to work fine. Generic USB keyboards may be used to enter Name and Numerical Position. The Keyboard can also emulate the key of NavNet3D: USB Keyboard Action ESC CANCE...
39 2.9.2. Audio Audio In and Audio out are reserved for future Development Note: If Sirius Satellite Radio control and functionality is desired in the future, be sure to use the Audio Outputs on the Sirius Receiver (BBWX1) itself and not from an MFD! 2.10. MFD8/12 Video, USB and Audio Connection The...
40 2. Pass DVI-D, VIDEO, AUDIO and/or USB cables through the fixing plate (supplied). 3. Attach each connector to the appropriate location at the rear of the display unit. 4. Pass cables through the slit on the boot cover. 5. Install the rubber stopper to each cable. The largest hole is for the DVI-...
42 2.10.2. Non Waterproof connection When you do not need waterproofing, use the cable fixing plate (supplied in standard installation materials). 1. Unfasten the four screws to detach the connector cover at the rear of the display unit. 2. Attach the cable fixing plate by using the binding screw (M...
43 3. Configuration 3.1. Introduction NavNet3D (just like NavNetVX2) uses Ethernet to share radar/sounder images and other navigation information from devices connected within a networked system. In any single NN3D network, a combination of up to ten NavNet3D MFDs may be connected to each other via ...
45 “Own Setting” Tab This Tab configures the local ports of the MFD (NMEA0183 Input/Output, NMEA2000 Output) on which the Installation Wizard is currently used. This is also where the Master can be designated (DHCP Server turned ON) “Global” Tab This Tab contains configuration information that is gl...
48 External Monitor for more information on Clone and Extended mode when two monitors are connected to a single MFDBB processor. After enabling the DHCP server click on “Exit” to validate the setting. The MFD will Power OFF automatically! Power ON the “Master” MFD. Wait a few minutes until the Insta...
49 Click on the “Next” button to continue the configuration. 3.2.3. NMEA0183 The three “NMEA0183 Port” tabs are used to configure the Input and Output of the individual MFD’s own NMEA0183 ports. It is important to understand that it is not possible to filter any received NMEA0183 Data at any of thes...
50 IMPORTANT!: After configuring any NMEA0183 Input Port Sensors on the Master MFD, you must REPEAT THIS PROCEDURE at any other Slave MFDs in the network where you have connected NMEA0183 Input Sensors!! If this is not done, the sensors will not be available for selection as a Primary System Data So...
52 is available again or the alarm is acknowledged (by key operation). Off: Alarm sounds three times. -After completing the NMEA0183 Configuration Procedures on the Master and Slave MFDs, return to the Master MFD to complete the installation process. -Click “Next” at the Master MFD to continue the c...
56 “Own” settings for each MFD(s) before being able to select the corresponding instruments as a data source. Select the “Data Source” Tab. This tab allows you to select the Primary System Data Source for various data types used by the Navnet 3D Network. Name Description Example Position & SOG/C...
58 3.3.5. Sounder Configuration Up to 2 Network sounders can be connected on the NavNet3D network. DFF1 and DFF3 Select the Sounder Source: a) Click the Transducer Setup pull-down menu, and choose Model Number, TD-ID or Manual, according to the transducer connected. Model Number: Furuno’s transducer...
60 3.3.6. DRS (Radar) Configuration Up to two DRS can be connected on the NavNet3D network. - Select the Radar Source you want to configure - Click the Antenna Height pull-down menu, and choose the height of the antenna above the waterline, among under 10ft, 10ft-30ft or over 30ft. - Perform the hea...
62 MFDBB Keyboard/Processor Linking then continue to the next paragraph to finish the Radar Installation. When the MFD displays the main interface, push the [MENU] key. Use the RotoKey to scroll to the “Radar” page. Use the Cursor Pad or the mouse and click on “Radar Source” to select the DRS you wa...
63 3.4. MFDBB Keyboard/Processor Linking MFDBB Keyboards are Ethernet network devices that need to be assigned (linked) to a specific MFDBB processor unit during installation. A special “key-push” sequence is used to cycle through the “Linking Codes” for all the MFDBB processor unit(s). If only one ...
64 4. Registering the System 4.1. SystemID Description The Navnet 3D SystemID is a unique number assigned to a complete NN3D networked system with one or more MFDs. On the same boat, all networked MFDs have the same SystemID. This number will not change if a MFD or other NavNet Component is added to...
66 5.1.2. Basic Plotter/Radar/Fish Finder Installation This is a single station Plotter/Radar/Fish Finder installation. The Furuno GPS (FUSA P/N BBWGPS) is directly connected to 7-Pin Port DATA1 of the MFD. Since two Ethernet sensor are on the network (DRS Radar and Fish Finder), a network switch (F...
69 5.1.4. Dual Screen MFDBB Installation with Pilot Integration Navpilot 500 Series Integration with NN3D MFDs is similar to Navnet vx2 integration. One difference is that NN3D MFDs no longer have an AD10 Heading Port. However, NN3D MFDs do require high speed NMEA0183 heading information (10Hz) for ...
70 In this example, the MFDBB is configured for Extended Mode. The two monitors show independent screen displays that can be configured independently. Only one Keyboard is used to control both monitors (the cursor will “jump” back and forth from monitor to monitor). The two screens need to be locate...
71 5.2. Configuring AXIS IP Cameras 5.2.1. Introduction: In order to view and control Axis IP Cameras from an MFD in a Navnet 3D network, it is first necessary to assign the IP Address of a MPEG-4 capable AXIS IP Camera. This procedure will require a Windows PC connected via Ethernet to the AXIS IP ...
73 Note that the new IP can take up to 20 seconds to be recognized. A pop-up in the lower right corner should show when the IP is correctly set. Turn OFF any Firewall that could prevent data to be exchanged between NavNet and the PC. You may also have to restart your computer. 5.2.3. Set up the IP a...
74 Click on “Copy to PC” The following window should appear. Just double click on “IPUtility” to launch the configuration software Note: If the Windows Firewall appears, click on “Unblock” to allow the software to configure correctly the IP Camera
75 The AXIS IP utility will detect all the IP cameras connected on the network Note: If you use the same camera models in multiple locations, BE SURE to WRITE DOWN the IP Camera serial number (that can be found on the back of the camera) with the intended location to help correctly assign the IP cam...
78 When the webpage loads, pay attention to the top of the page to authorize the installation of the ActiveX. Click on the yellow bar and choose “Install ActiveX” At this point a camera image should appear Now, click on Setup
NAME OUTLINE Q'TY DESCRIPTION/CODE № PACKING LIST 19BA-X-9851 -4 MFD8-J/E 1/1 NAME OUTLINE Q'TY DESCRIPTION/CODE № ユ ニッ ト UNI T マ ルチ ファン クシ ョンディスプ レイ MU LT I F UN CTI ON DI SP LAY 1 ** MF D8 -J /E 000-011-776-00 予 備品 SPA RE PA RT S 予備品 SP AR E P AR TS 1 SP 19 -0 070 1 001-028-020-00 付 属品 ACC ES SO...
Furuno Manuals
-
Furuno FAR2XX7
Manual
-
Furuno FR-7112
Manual
-
Furuno FM-7000
Manual
-
Furuno fr8100d
Manual
-
Furuno DS-60
Manual
-
Furuno FR-8111
Manual
-
Furuno 851 MARK-2
Manual
-
Furuno 1723C
Manual
- Furuno FAR-3220 Manual
-
Furuno WX2-012-551
Manual
-
Furuno FSV-35
Manual
-
Furuno 2167DS-BB
Manual
-
Furuno GP-3100
Manual
-
Furuno FR-2110
Manual
-
Furuno FS-1575/2575/5075
Manual
-
Furuno CH-300
Manual
-
Furuno VR-3000S
Manual
-
Furuno 1650WDF
Manual
-
Furuno GD-1920C-BB
Manual
-
Furuno GP-1850WDF
Manual